1. Vokatra mihoatraview
The GEYA GRT6-B2 is an electronic delay off time relay designed for industrial and domestic applications. It features adjustable delay settings and is suitable for DIN rail mounting. This manual provides essential information for safe installation, operation, and maintenance.
Lafin-javatra fototra:
- Adjustable Delay: Delay can be set directly via panel knobs for convenience and intuitive control.
- Fomba fiasa: Supports two primary functions: Delay ON (A) and Delay OFF (B). The GRT6-B2 model features 2SPDT (2NO2NC) contacts.
- Saro-potoana midadasika: Time scale from 0.1 seconds to 10 days, divided into 10 selectable ranges.
- Toetra famantarana: Equipped with LED indicators for power (green light) and working status (red light).
- Design Compact: Ultra-small size, only 18mm width, designed for 35mm DIN rail mounting.

2. Information momba ny fiarovana
Please read this manual carefully before installation and operation. Failure to follow these instructions may result in equipment damage, injury, or death. This device should only be installed and serviced by qualified personnel.
- Always disconnect power before installing, wiring, or performing maintenance on the device.
- Ataovy azo antoka fa mifanaraka amin'ny kaody elektrika eo an-toerana sy nasionaly ny tariby rehetra.
- Aza ampiasaina ny fitaovana raha simba na tsy mandeha tsara ny asany.
- Arovy amin'ny hamandoana sy ny vovoka ary ny hafanana tafahoatra ny fitaovana.
- Hamarino fa marina ny voltage and current ratings before connecting to a power source.
3. Product Dimensions and Components
The GRT6-B2 relay is designed for compact installation on a DIN rail. Understanding its dimensions and component layout is crucial for proper integration into your system.


4. Fametrahana sy Wiring
The GEYA GRT6-B2 relay is designed for easy installation on a 35mm DIN rail. Follow these steps for secure mounting and correct electrical connections.
4.1 DIN Rail Mounting
The relay snaps onto a standard 35mm DIN rail. Ensure it is securely fastened to prevent movement during operation.
4.2 Wiring elektrika
Refer to the wiring diagrams below for proper connection of the power supply and load. Always ensure power is disconnected before wiring.

4.3 Power Connection Demonstration
Watch this video for a visual guide on connecting power and load to the GRT6-B1 model, which shares similar wiring principles with the GRT6-B2.
5. Torolàlana miasa
The GRT6-B2 relay offers adjustable delay functions. Follow these steps to configure and operate your device.
5.1 Fomba fiasa
The GRT6-B2 supports two main function modes:
- A: Delay ON: The output contacts close after a set delay time once power is applied.
- B: Delay OFF: The output contacts open after a set delay time once the trigger signal is removed or power is disconnected.

5.2 Fametrahana fotoana
The delay time is set using two rotary knobs on the front panel: one for time range and one for percentage.

5.3 LED famantarana
- LED Maitso: Manondro ny satan'ny famatsiana herinaratra.
- LED mena: Indicates the working status of the relay (e.g., timing in progress, output active).
6. Fikojakojana
The GEYA GRT6-B2 time relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity and proper function.
- Fanadiovana: Tazomy ho madio sy tsy misy vovoka na loto ny fitaovana. Ampiasao lamba maina sy malefaka ny fanadiovana. Aza mampiasa ranoka fanadiovana.
- Fanaraha-maso: Periodically inspect wiring connections to ensure they are secure and free from corrosion. Check for any signs of physical damage or overheating.
- Tontolo iainana: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent premature failure.
7. Famahana olana
If the GEYA GRT6-B2 relay is not functioning as expected, consider the following common issues:
- No Power Indication (Green LED Off): Check the power supply connections (A1, A2) and ensure the voltage is within the specified range (AC/DC 24V-240V).
- Relay Not Activating/Deactivating:
- Verify the function mode (A or B) is correctly selected.
- Check the time range and percentage fika.
- Ensure the trigger signal (S) is correctly applied for Delay OFF functions.
- Inspect load connections and ensure the load is functioning correctly.
- Diso fotoana: Re-check the time range and percentage settings. Ensure the knobs are firmly set to the desired values.
- Mafana be loatra: If the device feels excessively hot, check the load current to ensure it does not exceed the relay's maximum rating (10A/AC1).
If problems persist after checking these points, contact a qualified electrician or the manufacturer for assistance.
8. Famaritana
Detailed technical specifications for the GEYA GRT6-B2 time relay.

| fikirana | sarobidy |
|---|---|
| Marika | GEYA |
| MODELY | GRT6-B2 |
| asa | Delay ON (A), Delay OFF (B) |
| Famatsiana Terminals | A1-A2 |
| BOKYtage Range | AC/DC 24V-240V (50-60Hz) |
| Fampidirana herinaratra | AC max. 6VA/1.9W |
| Vanim-potoana | 0.1s - 10 days (ON, OFF) |
| Fametrahana ora | Potentiometer |
| Output | 2xSPDT (2NO2NC) |
| Rating amin'izao fotoana izao | 10A/AC1 |
| Switching Voltage | 250VAC/24VDC |
| Temperature miasa | -20°C hatramin'ny +55°C (-4°F hatramin'ny 131°F) |
| Temperature fitehirizana | -35°C hatramin'ny +75°C (-22°F hatramin'ny 158°F) |
| fitomboan'ny | DIN rail EN/IEC 60715 |
| refy (L x W x H) | 64mm x 18mm x 95mm (eo ho eo) |
| lanja | Approx. 2.08 oz |
9. Warranty sy fanohanana
For warranty information, please refer to the documentation provided with your purchase or contact your seller. If you require technical support or have questions regarding the GEYA GRT6-B2 time relay, please reach out to the manufacturer or authorized distributor.