1. Fampidirana
Thank you for choosing the AQQA DC Aquarium Water Pump. This manual provides essential information for the safe and efficient operation of your pump. Designed for versatility, this pump is suitable for various aquatic environments, including freshwater and saltwater aquariums, ponds, fountains, and hydroponic systems. Its smart control features, quiet operation, and durable design ensure reliable performance.

Image 1: AQQA DC Aquarium Water Pump, showing the pump unit, external controller, and two interchangeable nozzles.
2. Information momba ny fiarovana
Please read all safety instructions carefully before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Esory foana ny herinaratra alohan'ny hanaovana fikojakojana, fametrahana, na fanadiovana.
- Ensure the pump is fully submerged in water during operation to prevent dry burning and damage.
- Aza miasa ny paompy raha simba ny tadin-jiro na ny plug.
- This pump is designed for indoor use in aquatic environments only. Do not use it for purposes other than those specified.
- Arovy amin'ny ankizy.
- The pump operates on a 12V DC low-voltage output, reducing shock risks. However, always handle electrical components with care.
3. Ny votoatin'ny fonosana
Hamarino fa ao anatin'ny fonosanao ny entana rehetra:
- 1 x AQQA DC Aquarium Water Pump
- 1 x External Controller
- 2 x Interchangeable Nozzles (6/8mm and 10/12mm)
- 1 x Power Cord (approximately 10.83 ft)
- 1 x Boky Torolàlana
4. Vokatra mihoatraview
The AQQA DC Aquarium Water Pump is a compact and efficient submersible pump featuring an external controller for easy operation.
Pump Unit Features:
- Famolavolana anaty rano: IP68 waterproof rating for continuous underwater operation.
- Hetsika mangina: Pure copper motor ensures low noise levels (<30dB).
- Kaopy setroka (Suction Cups): Four strong suction cups on the base for secure placement.
- Famolavolana ny haavon'ny rano ambany: Capable of operating effectively at water levels as low as 1.5cm (0.59 inches), allowing for thorough drainage.
- Anti-Dry Burning Protection: Automatically shuts off if water levels are too low to prevent damage.

Image 2: The AQQA pump unit highlighting its anti-dry burning protection feature, which prevents damage when water levels are too low.
External Controller Features:
- Bokotra ON/OFF: Powers the pump on or off.
- Flow Adjustment Buttons (+/-): Adjusts water flow rate across 4 levels.
- bokotra FEED: Activates feeding mode, pausing the pump for 10 minutes.
- Jiro famantarana: Display current flow rate/lift level and feeding mode status.

Image 3: Close-up of the external controller, showing the ON/OFF, flow adjustment (+/-), and FEED buttons, along with indicator lights for flow rate and feeding mode.
5. Fametrahana
Follow these steps to install your AQQA DC Aquarium Water Pump:
- Mifidiana Nozzle: Select the appropriate nozzle (6/8mm or 10/12mm) for your tubing system and securely attach it to the pump's outlet.
- Position paompy: Place the pump unit at the desired location within your aquarium, pond, or water feature. Ensure it is fully submerged. The four suction cups on the base will help secure it to a clean, smooth surface.
- Connect Controller: Connect the pump's cable to the external controller.
- Hery mampifandray: Plug the power cord from the controller into a suitable electrical outlet (110V-240V).
- Hamarino ny haavon'ny rano: Ensure the water level is sufficient to cover the pump completely. The pump can operate at low water levels (down to 1.5cm) but full submersion is recommended for optimal performance and longevity.

Image 4: The AQQA pump demonstrating its ability to operate effectively at low water levels, with all-around suction at the bottom to remove dirt.
6. Torolàlana miasa
The external controller provides easy access to all pump functions.
Herim-batana / maty:
- Tsindrio ny ON/OFF button once to turn the pump on or off.
Adjusting Flow Rate:
- Ampiasao ny + button to increase the flow rate.
- Ampiasao ny - button to decrease the flow rate.
- There are 4 adjustable flow levels, indicated by the lights on the controller.
Fomba famahanana:
- To activate feeding mode, press and hold the fahana bokotra mandritra ny 5 segondra.
- The pump will pause for 10 minutes, allowing fish to feed without strong currents.
- After 10 minutes, the pump will automatically restart at its previous flow setting.
Video 1: Demonstrates the AQQA DC Water Pump's internal circulation, ultra-quiet operation, oxygen generation, wave-making capability, and the feeding mode function with the external controller.
7. Fikojakojana
Regular cleaning and maintenance will ensure the longevity and optimal performance of your pump.
- Tapaka ny hery: Always unplug the pump from the power outlet before any maintenance.
- Disassemble Pump: The pump is designed for tool-free disassembly. Gently remove the filter cover and then the impeller assembly.
- Ireo singa madio: Rinse all parts (impeller, filter cover, pump housing interior) under clean water. Use a soft brush to remove any accumulated debris, algae, or mineral deposits. Ensure the impeller spins freely.
- Manangona indray: Carefully reassemble the pump, ensuring all parts fit correctly.
- Fanamarinana tsy tapaka: Periodically check the pump and tubing for any blockages or wear.

Sary 5: Nipoaka view of the AQQA pump, illustrating how to easily disassemble the outlet nozzle, filter cover, and motor for cleaning without tools.
8. Famahana olana
If you encounter issues with your pump, refer to the following common problems and solutions:
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy manomboka ny paompy | No power; Impeller jammed; Dry burning protection activated. | Check power connection; Disconnect and clean impeller; Ensure pump is fully submerged. |
| Ny tahan'ny fikorianan'ny ambany | Blockage in pump or tubing; Flow rate set too low; Impeller worn. | Clean pump and tubing; Increase flow rate using controller; Inspect/replace impeller if necessary. |
| tabataba be loatra | Debris in impeller; Pump not securely placed; Air trapped in pump. | Clean impeller; Re-secure pump with suction cups; Gently shake pump to release air. |
| Mijanona tsindraindray ny paompy | Dry burning protection; Overheating; Loose connection. | Check water level; Ensure adequate ventilation (if applicable); Check all electrical connections. |
9. Famaritana
| endri-javatra | famaritana |
|---|---|
| Laharana modely | AQ169 |
| fahefana | 25 Watts |
| Taham-pidirana ambony indrindra | 2200 Liter isan'ora (480 GPH) |
| Haavo ambony ambony | 7.2 Feet |
| BOKYtage Ampidiro | 110-240V / 50-60Hz |
| BOKYtage Output | 12v dc |
| Ny refin'ny vokatra | 2.6" L x 2" W x 3" H |
| Lanja entana | 12.8 oz |
| KEVITRA | Acrylonitrile Butadiene Styrene (ABS) |
| IP Rating | IP68 |
| Haben'ny nozzle | 6/8mm, 10/12mm |
| Ny halavan'ny tady herinaratra | 10.83 ft |
10. Warranty sy fanohanana
AQQA stands behind the quality of its products. For specific warranty details and terms, please refer to the warranty information provided at the time of purchase or visit the official AQQA website.
If you require technical assistance, have questions about your product, or need to report an issue, please contact AQQA customer support through the retailer where you purchased the product or via the contact information available on the official AQQA website.
Please have your model number (AQ169) and purchase date ready when contacting support.





