Extech ET11

Extech ET11 GFCI Receptacle Tester User Manual

Modely: ET11

1. Vokatra mihoatraview

The Extech ET11 is a GFCI Receptacle Tester designed for Type B electrical outlets. It is used to test for correct wiring of 3-wire receptacles in 110-125 V AC, 50/60 Hz circuits and to confirm the operation of Ground Fault Circuit Interrupter (GFCI) protective devices.

Extech ET11 GFCI Receptacle Tester front view

Sary: Front view of the Extech ET11 GFCI Receptacle Tester, showing the indicator lights and test button.

Extech ET11 GFCI Receptacle Tester with text overlay

Image: The Extech ET11 GFCI Receptacle Tester with text indicating its purpose for Type B electrical outlets and its ability to detect wiring faults.

2. endri-javatra

  • Tests for correct wiring of 3-wire receptacles in 110-125 V AC, 50/60 Hz circuits.
  • Detects 5 common wiring faults: Correct, Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, and Hot/Neutral Reverse.
  • Works on GFCI outlets and confirms operation of the ground fault protective device.
  • Conveniently verifies both ‘ground bottom’ and ‘ground top’ style sockets with a test code light legend on both sides of the device.
  • Ergonomic pull bar design for easy removal from outlets.
Extech ET11 showing ergonomic pull bar

Image: Close-up of the Extech ET11 highlighting its ergonomic pull bar for easy removal from outlets.

3. Torolàlana miasa

3.1. Testing Standard Receptacles

  1. Ensure the receptacle is powered and safe to approach.
  2. Insert the Extech ET11 tester firmly into the 3-wire receptacle.
  3. Observe the indicator lights on the tester. Refer to the wiring fault legend printed on the tester for interpretation.
  4. The combination of illuminated lights will indicate the wiring status (e.g., Correct, Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse).
  5. Remove the tester from the receptacle once the reading is taken.
Extech ET11 in use on a GFCI outlet

Image: The Extech ET11 GFCI Receptacle Tester plugged into a GFCI outlet, demonstrating its use for testing wiring.

Electrician using Extech ET11

Image: A person wearing work gloves and safety vest using the Extech ET11 to test an electrical outlet.

3.2. Testing GFCI Receptacles

  1. First, perform a standard wiring test as described above to ensure the receptacle is correctly wired.
  2. If the wiring is correct, press the GFCI test button on the Extech ET11 tester.
  3. A working GFCI outlet should trip, cutting power to the receptacle. The GFCI reset button on the outlet should pop out.
  4. If the GFCI does not trip, it indicates a fault with the GFCI mechanism or wiring.
  5. To restore power, press the reset button on the GFCI outlet.

3.3. Interpreting Indicator Lights

The Extech ET11 features a clear light legend on both the front and back to help interpret wiring conditions. The legend uses combinations of three indicator lights (typically amber/orange) to show the status.

Extech ET11 front and back with wiring legend

Sary: Eo anoloana sy aoriana views of the Extech ET11 GFCI Receptacle Tester, clearly showing the wiring fault legend with light patterns for 'Open Ground', 'Open Neutral', 'Open Hot', 'Hot/Ground Reverse', 'Hot/Neutral Reverse', and 'Correct' wiring.

Wiring Fault Legend
toe-javatraLight 1 (Left)Light 2 (Middle)Light 3 (Right)
marinaNIALAOnOn
Open GroundNIALAOnNIALA
Misokatra tsy miandanyOnNIALAOn
Sokafy HotNIALANIALANIALA
Mafana/tany mivadikaOnOnNIALA
Hot/Neutral ReverseOnNIALANIALA

4. Fikojakojana sy fikarakarana

  • Keep the tester clean and free from dust and debris. Wipe with a dry, soft cloth.
  • Do not expose the tester to extreme temperatures or moisture.
  • Store the tester in a safe place when not in use to prevent damage to the prongs or casing.
  • The Extech ET11 does not require batteries or user-serviceable parts. Do not attempt to open or repair the device.

5. Famahana olana

If the Extech ET11 tester does not function as expected, consider the following:

  • No lights illuminate: Ensure the receptacle is live and properly powered. Test with a known working outlet.
  • Famakiana tsy mifanaraka: Ensure the tester is fully inserted into the receptacle. Check for loose connections in the outlet itself.
  • GFCI does not trip: If the GFCI test button is pressed and the GFCI outlet does not trip, this indicates a fault with the GFCI mechanism or the wiring to the GFCI. Consult a qualified electrician.
  • Fahavoazana ara-batana: If the tester appears physically damaged, discontinue use immediately and replace the unit.

6. Famaritana

Extech ET11 product dimensions and weight

Image: The Extech ET11 GFCI Receptacle Tester shown alongside its product size (4.26 x 1.78 x 1.1 inches) and weight (1.6 oz), and a note that it includes the tester and user manual.

famaritanaantsipirihany
Laharana modelyET11
mpanamboatraExtech
Laharan'ny ampahanyET11
Lanja entana2.29 oz
Ny refin'ny vokatra0.63 x 0.63 x 0.12 santimetatra
Firenena nihavianaCHINE
Ny entana fonosana1
Fahamarinana fandrefesana+/-0.5%
Anisan'ny singaTesters elektrika
Ilaina ny bateria?tsy misy
ASINB0D431PZXS
Daty misy voalohany13 Mey 2024

7. Warranty sy fanohanana

Specific warranty information for the Extech ET11 GFCI Receptacle Tester is typically provided with the product packaging or can be found on the official Extech website. For detailed warranty terms, service, or technical support, please refer to the contact information provided by Extech.

You can visit the official Extech webtranonkala hahazoana fanampiana fanampiny: www.fitsong.com

Documents mifandraika - ET11

Preview Extech ET10 GFCI Receptacle Tester User Manual
User manual for the Extech ET10 GFCI Receptacle Tester. Provides instructions for testing standard and GFCI receptacles, explains indicator lights, and details warranty and support information.
Preview Boky Torolàlana ho an'ny Mpampiasa ny Extech ET40 Heavy Duty Continuity Tester
Boky torolalana ho an'ny mpampiasa ny Extech ET40 Heavy Duty Continuity Tester. Mianara ny fomba fitsapana azo antoka sy mahomby ny fitohizan'ny singa tsy misy herinaratra, fuses, switches, relays, tariby ary circuit boards.
Preview EXTECH 40180 Tone Generator sy AmpLifier Probe User Manual
Boky torolalana ho an'ny mpampiasa ny EXTECH 40180 Tone Generator sy Amplifier Probe. Mianara momba ny endri-javatra, ny fomba fiasa, ny famaritana ary ny famahana olana amin'ny fanaraha-maso tariby sy ny fitsapana ny tsipika an-telefaona.
Preview Tondro roa sosona Extech ET20 Voltage Boky torolalana ho an'ny mpampiasa mpitsikilo
Boky torolalana ho an'ny mpampiasa ny Extech ET20 Dual Indicator Vol.tage Detector, Volo AC/DC 2-LalanatagMpandrefy e (100-250V). Manome fampahalalana momba ny fampiasana, ny antoka ary ny serivisy.
Preview Extech CT20 Continuity Tester Pro User Manual - Features, Specifications, and Operation
Comprehensive user manual for the Extech CT20 Continuity Tester Pro. Learn about its features, specifications, safety precautions, local continuity testing, and advanced remote continuity and wire identification capabilities.
Preview Extech PRC10 Current Calibrator User Guide
Torolàlana mpampiasa feno ho an'ny Extech PRC10 Current Calibrator. Mianara momba ny endri-javatra, ny fomba fiasa (Measure, Source), ny torolàlana momba ny fiarovana, ny famaritana ary ny serivisy calibration avy amin'ny Extech Instruments, orinasa FLIR Systems.