Remco 5537-1E1-65C

Remco 5500 Series ProFlo Demand Pump 5537-1E1-65C Instruction Manual

Sava lalana

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Remco 5500 Series ProFlo Demand Pump, model 5537-1E1-65C. This professional-grade pump is designed for various agricultural and industrial spraying applications, offering reliable performance and durability.

Information momba ny fiarovana

Please read and understand all safety instructions before operating the pump. Failure to follow these guidelines may result in injury or damage to the equipment.

Vita ny vokatraview

The Remco 5500 Series ProFlo Demand Pump is a robust 5-chamber diaphragm pump designed for demanding applications. It features a sealed 115 VAC electric motor and durable components for long, continuous duty cycles.

Remco 5500 Series ProFlo Demand Pump model 5537-1E1-65C

Sary 1: Remco 5500 Series ProFlo Demand Pump. This image displays the pump with its silver motor housing, black pump head, and black mounting bracket. A label on the motor housing indicates the model number 5537-1E1-65C, flow rate of 5.3 GPM, 115 VAC voltage, and 60 PSI pressure rating. A power cord is visible extending from the motor.

Lafin-javatra fototra:

Hametraka

  1. Mametraka: Securely fasten the pump to a stable surface using the integrated mounting bracket. Ensure the pump is positioned to allow for proper ventilation and access for connections.
  2. Plumbing Connections: Connect your inlet and outlet lines to the 1/2" FNPT threaded ports. Use appropriate fittings and sealants to ensure leak-free connections. The pump is self-priming up to 14 feet (4.0 meters) vertically.
  3. Fifandraisana elektrika: Connect the 14 AWG wire leads to a dedicated 115 VAC power supply. Ensure the power source is fused and protected according to local electrical codes. Verify correct polarity.
  4. System Priming: Before initial operation, ensure the pump and lines are filled with liquid to facilitate priming.

hetsika

The Remco 5500 Series pump operates in demand mode, meaning it will run when there is a demand for fluid and shut off when the system pressure reaches 60 PSI. This allows for efficient operation and reduced power consumption.

fikarakarana

Regular maintenance ensures the longevity and optimal performance of your Remco pump.

Fanamboarana

This section provides general guidance for common issues. For complex problems, contact Remco customer support.

OLANAAntony mety hitrangavahaolana
Tsy manomboka ny paompyNo power, loose electrical connection, faulty switch.Check power supply, verify connections, test switch.
Fikorianan'ny rivotra na tsindry ambanyClogged inlet filter, air leak in suction line, worn diaphragm, low voltage.Clean filter, check for leaks, inspect diaphragm, verify voltage.
Ny paompy dia mandeha tsy tapakaLeak in system, faulty pressure switch, air in system.Check for leaks, inspect pressure switch, bleed air from system.
Fitabatabana na vibration be loatraLoose mounting, cavitation (air in line), debris in pump.Tighten mounting, ensure proper priming, inspect for debris.

fepetra arahana

MarikaRemco
Laharana modely5537-1E1-65C
Karazana paompy5 Chamber Diaphragm Pump
Modefangatahana
BOKYtage115 VAC
Taham-pidirana ambony indrindra5.3 GPM (20.06 LPM)
Fametrahana fanerena60 PSI (4.1 Bar)
Fluid Port1/2" FNPT threaded Ports
ValvesViton
DiaphragmSantoprene
Wire Leads14 AWG - 6" or 12" 2-Pin Mold / Custom Connection
Self-PrimingUp to 14' (4.0 m) vertically
Cycle adidymitsitaitaika
Dry Run CapabilityENY
Temperature ranoka max140°F (60°C)
Max Motor Temperature180°F (82°C) (Surface temp should not exceed 150°F / 66°C)
UPC816624019041
Anisan'ny singapaompy

Warranty sy fanohanana

For information regarding product warranty, technical support, or replacement parts, please contact Remco directly through their official website or customer service channels. Keep your purchase receipt and model number (5537-1E1-65C) handy for faster service.

You can visit the Remco store on Amazon for more information: Remco Store

Documents mifandraika - 5537-1E1-65C

Preview REMCO ProFlo 3300, 5500, FatBoy Diaphragm Pumps: Boky Fampiasana, Fametrahana ary Fanamboarana
Torolàlana momba ny fampandehanana, ny fametrahana, ny famahana olana ary ny ampahany ho an'ny paompy diaphragm REMCO ProFlo 3300, 5500, ary FatBoy. Ahitana tabilao fampisehoana, angona fiakaran'ny hafanana, ary fampahalalana momba ny fiantohana mahazatra.
Preview Remco 5500 Series Pumps: Torolàlana momba ny fampandehanana sy ny fametrahana
Torolàlana fampandehanana sy fametrahana feno ho an'ny paompy Remco 5500 Series, mirakitra ny fepetra fiarovana, fametrahana, fantson-drano, fifandraisana elektrika, fomba fametrahana, serivisy, famahana olana ary kojakoja fanoloana.
Preview REMCO Professional Grade Pump Products Catalog
Comprehensive catalog of REMCO's professional-grade diaphragm pumps, including series like 3300, 3200, 5500, Zeus, SmoothFlo, RollMax, and PowerRV, along with accessories and custom pump solutions.
Preview REMCO Economy Plus 2200 2400 Pumps: Boky Fampiasana & Fametrahana
Torolàlana momba ny fampandehanana sy fametrahana, famaritana, refy ary famahana olana ho an'ny paompy andiany REMCO Economy Plus 2200 sy 2400. Ahitana lisitry ny kojakoja sy fampahalalana momba ny fiantohana ho an'ireo paompy indostrialy mora vidy sy avo lenta.
Preview REMCO Accumulator/Pulsation Dampener Tank Installation & Maintenance Manual
Detailed installation, maintenance, troubleshooting, and warranty information for the REMCO RACT820-NPT and RACT820-JG Accumulator/Pulsation Dampener Tanks. Learn how to optimize pump performance and system longevity.
Preview Remco STAR 4 u 1: Univerzalni Daljinski Upravljač - Uputstvo i Kodovi
Saznajte kako da podesite i koristite vaš Remco STAR 4 u 1 univerzalni daljinski upravljač. Pronađite uputstva za pretragu kodova, funkciju učenja i rešavanje problema za TV, STB, SAT, DVD i BD uređaje.