Sava lalana
The Phrozen Cure Mega S is an advanced resin curing station designed for post-processing 3D printed models. It features both drying and UV curing functions, a 360-degree transparent turntable, and dual high-speed fans to ensure efficient and uniform curing of large and small models. This manual provides essential information for the safe and effective operation, setup, and maintenance of your Phrozen Cure Mega S.
Information momba ny fiarovana
Azafady vakio tsara ny toromarika fiarovana rehetra alohan'ny hampiasana ny fitaovana mba hisorohana ny ratra na ny fahasimbana.
- Always wear appropriate personal protective equipment (PPE), such as gloves and eye protection, when handling uncured resin or models that have not been fully cured.
- Ensure the device is placed on a stable, level surface away from direct sunlight and flammable materials.
- Do not look directly at the UV light source during operation.
- Keep the device away from water or other liquids to prevent electric shock.
- Esory amin'ny faladia ny fitaovana alohan'ny hanadiovana na hanaovana fikojakojana.
- Arovy amin'ny ankizy sy ny biby fiompy.
Vita ny vokatraview
The Phrozen Cure Mega S is a robust curing station designed for large-scale and high-volume post-processing. Its intuitive design allows for easy access and efficient operation.

Sary: Front view of the Phrozen Cure Mega S curing station, showcasing its compact, black enclosure with a transparent orange-tinted door.
Ireo singa fototra
- Main Curing Chamber: The enclosed space where models are dried and cured.
- Transparent Turntable: Rotates models 360 degrees for even curing.
- Loharano hazavana UV: Emits 405nm UV light for resin solidification.
- High-Speed Fans: Two fans for efficient drying of models.
- Touch Panel: User interface for controlling drying and curing settings.
- Removable Rack: Allows for flexible curing of various model sizes.
- Side-Swing Door: Provides easy access to the curing chamber.
- Built-In Interior Light: Illuminates the chamber for monitoring progress.

Image: Visual representation of the Phrozen Cure Mega S's smart design, highlighting the side-swing door, interior lighting, and the touch panel interface.
Hametraka
Follow these steps for the initial setup of your Phrozen Cure Mega S.
- Esory ny fitaovana: Carefully remove the Phrozen Cure Mega S from its packaging. Retain all packaging materials for future transport or storage.
- Misafidiana toerana iray: Place the curing station on a flat, stable, and heat-resistant surface in a well-ventilated area. Ensure there is sufficient space around the unit for air circulation.
- Hery mampifandray: Plug the power cord into the power input port on the back of the unit, then plug the other end into a grounded electrical outlet.
- Install Turntable: Place the transparent turntable securely onto the rotating mechanism inside the curing chamber.
- Optional Rack Installation: If curing smaller or multiple models, install the removable rack at the desired height within the chamber.
- Herim-batana: Press the power button on the touch panel to turn on the device.
hetsika
The Phrozen Cure Mega S offers versatile drying and curing options for your 3D printed models.
Drying and Curing Functions
The device allows you to select between drying, curing, or a combined dry and cure cycle.
- Fomba fanamainana: Utilizes dual high-speed fans (1700 RPM) to quickly dry models, removing residual alcohol or moisture after washing.
- Curing Mode: Activates the 405nm UV light source to solidify resin models, enhancing their hardness and durability. The 360-degree light source and rotating turntable ensure uniform exposure.
- Dry & Cure Mode: Performs a drying cycle followed by a curing cycle automatically, streamlining the post-processing workflow.

Image: Depicts the Phrozen Cure Mega S in operation, highlighting its dual-action drying (1700 RPM) and 360-degree curing capabilities.
Mampiasa ny Touch Panel
The touch panel provides intuitive control over the device's functions.
- Safidio ny fomba: On the main screen, tap the desired mode: Fan + Cure (Dry & Cure), UV Cure, na Fan (Drying).
- Fametrahana ora: Use the '+' and '-' buttons to adjust the duration for the selected mode. Recommended curing times vary based on resin type and model size.
- Manomboka tsingerina: Press the 'Start' button to begin the process. The interior light will activate, and the turntable will begin to rotate.
- Fanaraha-maso ny fandrosoana: Use the built-in interior light to observe the drying or curing state of your models through the transparent door.
- Famaranana ny tsingerina: The device will automatically stop once the set time has elapsed. You can also manually stop the cycle by pressing the 'Stop' button.

Image: Illustrates the detachable rack feature, showing how it accommodates both large single models and multiple smaller models for flexible curing.
fikarakarana
Regular maintenance ensures optimal performance and longevity of your Phrozen Cure Mega S.
- Fanadiovana ny efi-trano: After each use, especially if resin spills occur, wipe down the interior of the curing chamber with a soft cloth dampened with isopropyl alcohol (IPA). Ensure the device is unplugged.
- Fanadiovana ny latabatra (Chairing the Turntable): Remove the turntable and clean it with IPA. Ensure it is completely dry before placing it back into the unit.
- Fanadiovana ivelany: Fafao amin'ny lamba malefaka sy maina ny ivelany. Aza mampiasa mpanadio na ranoka manimba.
- Loharano hazavana UV: Periodically check the UV LEDs for any dust or residue and gently clean them with a soft, dry cloth if necessary.
- fitahirizana: Rehefa tsy ampiasaina mandritra ny fotoana maharitra dia tehirizo ao amin'ny toerana mangatsiatsiaka sy maina ary lavitry ny tara-masoandro mivantana ny fitaovana.
Fanamboarana
This section addresses common issues you might encounter with your Phrozen Cure Mega S.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy mandeha ny fitaovana. | Tsy mifandray tsara ny tariby herinaratra; tsy misy herinaratra avy amin'ny faladia. | Jereo ny fifandraisan'ny tariby herinaratra. Andrana amin'ny fitaovana hafa. |
| UV light not activating. | Curing mode not selected; door not fully closed. | Ensure 'UV Cure' or 'Fan + Cure' mode is selected. Close the door securely. |
| Turntable tsy mihodina. | Turntable not properly seated; obstruction. | Re-seat the turntable. Check for any debris obstructing rotation. |
| Models not curing evenly. | Insufficient curing time; models too close together. | Increase curing time. Ensure models are spaced adequately on the turntable. |
| Models not drying effectively. | Drying mode not selected; fans obstructed. | Ensure 'Fan' or 'Fan + Cure' mode is selected. Check for obstructions near fan vents. |
fepetra arahana
Technical specifications for the Phrozen Cure Mega S.
| endri-javatra | antsipirihany |
|---|---|
| Laharana modely | CUREMEGAS00US |
| Ny refin'ny vokatra | 15.6"D x 18.7"W x 19.1"H (39.5cm W x 47.5cm D x 48.6cm H) |
| Lanja entana | 15 kilao (33.07 kilao) |
| KEVITRA | Metal |
| Curing Wavelength | 405nm UV Light |
| Haingan'ny mpankafy | 1700 RPM (Dual Fans) |
| Turntable Rotation | 360 degre |
| mpanamboatra | PHROZEN TECH CO., LTD. |
| Daty azo alaina voalohany | 9 aogositra 2023 |

Image: Diagram showing the physical dimensions of the Phrozen Cure Mega S: 47.5cm depth, 39.5cm width, and 48.6cm height.
Warranty sy fanohanana
For warranty information, technical support, or service inquiries, please contact Phrozen customer support through their official webtoerana na ny mpivarotra nividianana ny vokatra.
Loharano an-tserasera: Visit the official Phrozen website for FAQs, updated drivers, and additional support materials.
Antsipiriany ifandraisana: Refer to your purchase documentation or the Phrozen webtranokala ho an'ny antsipiriany momba ny fifandraisana.