1. Fampidirana
Thank you for choosing the Garvee 1.6HP Pool Pump. This manual provides essential information for the safe installation, operation, and maintenance of your new pool pump. Designed for both in-ground and above-ground swimming pools, this pump features a 1.6HP motor, delivering a powerful flow rate of 6075 GPH and a maximum suction height of 52 feet. Its robust construction and efficient design ensure clear and sanitary pool water. Please read this manual thoroughly before use and retain it for future reference.
2. Information momba ny fiarovana
FAMPITANDREMANA: Mety hiteraka ratra mafy na fahafatesana ny tsy fanarahana ireo toromarika ireo.
- Always disconnect power to the pump before performing any maintenance or service.
- Ensure the pump is installed by a qualified professional in accordance with all local and national electrical and plumbing codes.
- Aza miasa ny paompy raha simba ny tadin-jiro na ny plug.
- Keep children and pets away from the pump and electrical connections.
- The pump must be installed on a solid, level surface to prevent vibration and ensure proper operation.
- Ensure adequate ventilation around the pump motor to prevent overheating.
- This product is not available for use or sale in the state of California due to motor limitation requirements by the CEC.
- During extreme weather conditions, such as heavy rain or storms, disconnect the pump from the power supply.
3. Ny votoatin'ny fonosana
Hamarino tsara fa eo daholo ny singa rehetra ary tsy misy simba rehefa esorina ny entana.
- 1 x Garvee 1.6HP Single Speed Pool Pump
- 1 x Extra-large Filter Basket with Clear Cover
- 1 x Drain Plug
- Connecting Pipe Fittings (G2-1/4" diameter)
- User Manual

Image: The Garvee 1.6HP Pool Pump shown with its various components, including the motor, pump housing, filter basket, clear lid, and pipe fittings.
4. Famaritana
| endri-javatra | famaritana |
|---|---|
| Marika | Garvee |
| Laharana modely | Paompy dobo |
| Hery naoty | 1.6 HP (1200W) |
| Nominal Voltage | 115V / 60Hz |
| Taham-pidirana ambony indrindra | 6075 GPH (101.25 Galona Isaky ny Minitra) |
| Haavony ambony indrindra | 52 Feet |
| Fanerena ambony indrindra | 1.6 bar |
| Karazana fiarovana | IPX4 |
| Maximum Grain Size | 2.5 mm |
| Connecting Pipe Diameter | G2-1/4" |
| KEVITRA | ABS and Aluminum |
| Lanja entana | 24 kg |
| Ny halavan'ny tady herinaratra | 6.56 feet (Copper) |

Image: A detailed diagram illustrating the Garvee 1.6HP Pool Pump with labels for its components such as the filter basket, inlet/outlet, drain plug, pure copper motor, and a table of specifications.
5. Fametrahana sy fametrahana
5.1 Fametrahana
- Position the pump on a firm, level surface as close to the pool as possible to minimize friction loss from plumbing.
- Ensure the location is well-ventilated and protected from direct sunlight and extreme weather.
- Allow sufficient space around the pump for maintenance and air circulation.
5.2 Fifandraisana amin'ny fantson-drano
- Connect the pool's suction line to the pump's inlet (front opening) and the return line to the pump's outlet (top opening).
- Use appropriate G2-1/4" diameter fittings and ensure all connections are sealed tightly to prevent air leaks, which can affect pump performance.
- It is recommended to use industrial-grade pipe thread tape for secure sealing.

Image: The Garvee Pool Pump illustrating the G2-1/4 inch diameter for connecting pipes at the inlet and outlet ports.
5.3 Fifandraisana elektrika
- Ensure the power supply matches the pump's requirements (115V/60Hz).
- Connect the pump to a grounded electrical outlet protected by a Ground Fault Circuit Interrupter (GFCI).
- Aza mampiasa tady fanitarana.
5.4 Fanomanana ny paompy
- Before starting the pump for the first time, or after draining, the pump must be primed.
- Remove the clear cover of the filter basket and fill the basket with water until it reaches the suction pipe level.
- Replace the cover and ensure it is securely tightened.
- Turn on the pump. It should begin to draw water and establish flow. If not, repeat the priming process.

Image: The Garvee Pool Pump illustrating the maximum suction height of 52 feet and the location of the drain plug for water removal.
6. Fampandehanana
6.1 Fanombohana ny paompy
- Ensure the pump is properly primed and all valves are open to allow water flow.
- Plug the pump into the GFCI-protected outlet. The pump will start automatically.
- Observe the water flow to ensure proper circulation.
6.2 Fiasa mitohy
- The pump is designed for continuous operation to maintain water clarity.
- Monitor the pressure gauge (if installed) to ensure the system is operating within normal parameters.
- The transparent cover of the filter basket allows for visual inspection of debris accumulation without interrupting operation.

Image: The Garvee Pool Pump demonstrating stable flow output and input, highlighting the efficient water circulation.
7. Fikojakojana
7.1 Fanadiovana ny harona sivana
- Regularly check the clear cover of the filter basket for debris accumulation.
- When the basket appears full, turn off the pump and disconnect power.
- Unscrew the clear cover and remove the basket.
- Empty and rinse the basket thoroughly. Inspect for any damage.
- Replace the basket and securely tighten the clear cover. Re-prime the pump if necessary before restarting.

Image: The Garvee Pool Pump with its large, detachable filter basket shown removed, illustrating its capacity for collecting leaves, hair, and other debris.

Sary: akaiky view of the detachable filter basket, emphasizing its ease of disassembly and cleaning for effective filtration of leaves, hair, and grits.
7.2 Fametrahana ny ririnina
- Before freezing temperatures arrive, drain all water from the pump to prevent damage.
- Locate the drain plug at the bottom of the pump and remove it to allow water to exit.
- Store the pump in a dry, protected area during the off-season.
7.3 Fanaraha-maso ankapobeny
- Periodically inspect the pump housing, motor, and connections for any signs of wear, cracks, or leaks.
- Ensure the power cord is intact and free from damage.
8. Famahana olana
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy manomboka ny paompy | No power, tripped GFCI, motor overload | Check power connection, reset GFCI, allow motor to cool if overheated. |
| Low water flow or no prime | Air leak in suction line, clogged filter basket, low water level in pool | Check all connections for leaks, clean filter basket, ensure adequate pool water level, re-prime pump. |
| Fitabatabana na vibration be loatra | Loose mounting, debris in impeller, motor bearing issue | Ensure pump is securely mounted, inspect impeller for obstructions (disconnect power first), contact support if motor noise persists. |
| Ny rano mitete avy amin'ny paompy | Loose fittings, damaged O-rings/seals, housing crack | Tighten fittings, inspect and replace O-rings/seals, inspect pump housing for damage. A customer reported a sand filter housing splitting after 4 months; regularly inspect housing for integrity. |
9. Warranty sy fanohanana
For warranty information, please refer to the documentation provided with your purchase or contact Garvee customer support directly. If you encounter any issues not covered in this manual or require further assistance, please reach out to the manufacturer's customer service department. Keep your purchase receipt and product model number handy for efficient service.