1. Fampidirana

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity AM W12 wood-burning stove with an integrated boiler for central heating. Please read this manual thoroughly before using the appliance and retain it for future reference. The Prity AM W12 is designed to provide both room heating and hot water for your central heating system.

2. Torolàlana momba ny fiarovana

Your safety and the safety of others are paramount. Always adhere to the following safety guidelines:

  • Fametrahana matihanina: Installation must be performed by a qualified professional in accordance with all local and national building codes and regulations.
  • Fitaovana mora mirehitra: Maintain minimum clearances from combustible materials. As per EN 13240:2001/A2:2004/AC:2007, the minimum distances are:
    • aoriana: 400 mm
    • Sides (left and right): 400 mm
    • Front (radiation from pane): 800 mm
    • Haavo: 600 mm
  • Karazana solika: Only use dry wood with a moisture content of ≤20% or charcoal. Never use flammable liquids, plastics, or treated wood as fuel.
  • Toerana mafana: The stove's exterior surfaces become extremely hot during operation. Use appropriate protective gloves when handling and keep children and pets away.
  • rivotra: Ensure adequate ventilation in the room where the stove is installed to prevent oxygen depletion.
  • Chimney/Flue: Regularly inspect and clean the chimney and flue pipe to prevent creosote buildup and ensure proper draft.
  • Carbon Monoxide: Install a carbon monoxide detector in the vicinity of the stove.
  • Rafitra rano: The integrated boiler must be connected to a closed central heating system by a qualified plumber. Ensure the system is properly filled and vented. The maximum working pressure is 1.25 bar.

This product complies with EN standard, CE certification, BlmSchV2, and ECO design regulations.

3. Fametrahana sy fametrahana

The Prity AM W12 is designed for corner placement and built-in installation. Proper setup is crucial for safety and performance.

3.1 Famoahana sy fisafoana

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately.

3.2 Fametrahana

Position the stove in the desired corner, ensuring it meets the minimum clearance requirements from combustible materials as detailed in the Safety Instructions section.

Prity AM W12 wood-burning stove installed in a corner with a fire burning inside.

Image 3.2.1: The Prity AM W12 stove installed in a corner setting, demonstrating typical placement.

3.3 Fifandraisana amin'ny sodina

Connect the stove to a suitable chimney or flue system. The flue pipe diameter required is 150 mm. Ensure all connections are sealed properly to prevent smoke leakage and ensure optimal draft.

3.4 Central Heating System Connection

The integrated water boiler requires connection to your central heating system. This must be done by a certified plumber. The boiler has a volume of 7 liters and is designed to operate at a maximum working pressure of 1.25 bar. Ensure the system is properly filled, vented, and tested for leaks before initial firing.

sisiny view of the Prity AM W12 wood-burning stove, showing the flue pipe connection point at the top.

Sary 3.4.1: lafiny view of the Prity AM W12 stove, highlighting the flue outlet and overall construction.

4. Torolàlana miasa

Follow these steps for safe and efficient operation of your Prity AM W12 stove.

4.1 Fueling the Stove

Open the main combustion chamber door using the wooden handle. Place a small amount of kindling and firelighters on the cast iron grate. Once ignited, gradually add small pieces of dry wood or charcoal. Do not overfill the combustion chamber.

Prity AM W12 wood-burning stove with a vibrant fire burning inside the combustion chamber.

Image 4.1.1: The Prity AM W12 stove in operation, showing a fire burning within the heat-resistant ceramic glass window.

Prity AM W12 wood-burning stove with the combustion chamber door closed, showing the empty interior and cast iron grate.

Image 4.1.2: The Prity AM W12 stove with the combustion chamber empty, illustrating the interior design and cast iron grate.

4.2 Air Supply Control

The stove is equipped with a front damper for regulating the air supply to the combustion chamber. Open the damper fully during ignition to establish a strong fire. Once the fire is established, adjust the damper to control the burn rate and heat output. A fully open damper provides more air, leading to a hotter, faster burn. A partially closed damper reduces air, resulting in a slower, more efficient burn.

4.3 Flame Intensity Adjustment

Setroka damper is provided to adjust the flame intensity. This allows for fine-tuning of the combustion process and heat distribution.

4.4 Fandotoana

When adding more fuel, open the air damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Add fuel carefully and close the door securely.

5. Fikojakojana

Regular maintenance ensures the longevity and efficient operation of your Prity AM W12 stove.

5.1 Fanalana lavenona

Regularly remove ash from the ash pan located below the combustion chamber. Ensure the stove is completely cool before performing this task. Dispose of ash in a non-combustible container.

5.2 Cleaning the Combustion Chamber

Periodically clean the interior of the combustion chamber, including the heat-resistant ceramic glass. Use a soft brush or vacuum cleaner for ash and a specialized glass cleaner for stove glass. Do not use abrasive cleaners.

5.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage. This prevents creosote buildup, which can lead to chimney fires and reduced efficiency. This task should be performed by a qualified chimney sweep.

5.4 Boiler System Check

Regularly check the pressure in your central heating system and ensure it is within the recommended operating range. Inspect all connections for leaks. Consult a qualified plumber for any issues with the boiler system.

6. Famahana olana

This section addresses common issues you might encounter with your Prity AM W12 stove. For complex problems, consult a qualified technician.

  • Poor Draft / Smoke in Room:
    • Check if the flue pipe or chimney is blocked and requires cleaning.
    • Ensure the air dampers are open sufficiently.
    • Verify that the chimney height and diameter are adequate for the stove.
    • Check for negative pressure in the room (e.g., due to extractor fans).
  • Famoahana hafanana ambany:
    • Ensure you are using dry, seasoned wood. Wet wood burns inefficiently.
    • Check if the air dampers are open enough.
    • Verify that the combustion chamber and ash pan are clean.
  • Fanjifana solika tafahoatra:
    • Ahitsio ny rivotra dampers to reduce the burn rate.
    • Ensure the stove door seals are intact and not allowing excess air.
  • Water System Not Heating:
    • Check the central heating system pressure.
    • Ensure the boiler is receiving sufficient heat from the combustion.
    • Bleed the radiators and the boiler system to remove any airlocks.
    • Consult a qualified plumber if the issue persists.

7. Famaritana

Detailed technical specifications for the Prity AM W12 wood-burning stove with boiler:

Table showing product information and technical specifications for Prity AM W12 stove.

Image 7.1.1: Product Information table for Prity AM W12, detailing various technical specifications.

endri-javatrafamaritana
Laharana modelyAM W12
Total Dimensions (W x D x H)720 x 550 x 820 mm
Combustion Chamber Dimensions (W x D x H)635 x 450 x 315 mm
Lanja afa-karatsaka113 kg
Nominal Room Heating Output6.2 kW
Nominal Water Heating Output7.3 kW
Maximum Water Heating Output12 kW
Savaivony fantsona fantsona150 mm
fahombiazana76.5%
Volume of Water Heater7 L
Estimated Heating Area105 m²
Estimated Heating Capacity277 m³
Fitaovana vatana2 mm thick sheet steel
Fitaovana ambony3-4 mm thick sheet steel
Karazana solikaWood, Charcoal (Dry wood with moisture content ≤20%)
Fanerena miasa ambony indrindra1.25 bar
Flue Gas Temperature at Nominal Heat Output180 °C
Minimum Chimney Draft11.4 Pa
Fanjifana solika4.3 kg/h
Fittings fifandraisana3/4"
Kilasy fahaiza-manao angovoA
Fanondrom-pahombiazana angovo (EEI)102
Fahombiazan'ny angovo fanafanana habakabaka (ηs)68%
lokoMainty grika
Anisan'izany ny singaCast iron grate, Wooden door handles
Energy efficiency label for Prity AMW12 stove, showing an A rating and heat output values.

Image 7.1.2: Energy Label for Prity AMW12, indicating an A-class energy efficiency rating.

German Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.3: German Declaration of Performance for Prity AMW12, showing compliance and performance data.

English Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.4: English Declaration of Performance for Prity AMW12, providing essential performance characteristics.

EAN/Barcode: 3800215095054

8. Warranty sy fanohanana

For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. In case of technical issues or questions not covered in this manual, please contact Prity customer support or your authorized service provider.

Documents mifandraika - AM W12

Preview Prity Boilers: Technical Description, Installation, and Operation Manual
Comprehensive guide for Prity residential boilers, covering technical specifications, installation procedures, operation instructions, maintenance, and troubleshooting for solid fuel and pellet models.
Preview W12 Wireless Portable Charger User Manual
Torolàlana ho an'ny W12 Wireless Portable Charger nataon'i Guangdong Gadmei Intelligent Technology Co., LTD. Mianara momba ny endri-javatra, ny famaritana, ny fomba famandrihana, ny fepetra fiarovana ary ny famahana olana.
Preview SANSUI W12 Bluetooth Headset - Specifications and FCC Compliance
Official information for the SANSUI W12 Bluetooth Headset, including technical specifications and FCC compliance statements.
Preview Boky Torolalana ho an'ny Mpampiasa ny Famandrihana Famantaranandro Tsy Misy Tambajotra Azo Aforitra Joyroom JR-W12
Boky torolalana ho an'ny fampiasana ny Joyroom JR-W12 azo aforitra Wireless Watch Charger, izay manazava amin'ny antsipiriany ny momba azy, ny fomba fiasany ary ny fampitandremana momba ny fiarovana. Ahitana fampahalalana momba ny fampidirana ny vokatra, ny dingana fampiasana, ny famaritana ny fiasany ary ny fanarahana ny torolàlana EU.
Preview Redkey W12 Pro 4-in-1 Boky torolalana ho an'ny mpanasa gorodona marobe
Boky torolalana feno ho an'ny Redkey W12 Pro 4-in-1 Multi-Functional Floor washer, mandrakotra ny fiarovana, ny fivoriambe, ny fandidiana, ny fikojakojana ary ny famahana olana.