Prity K2 CP

Prity K2 CP 10 kW Wood Stove User Manual

Model: K2 CP | Brand: Prity

1. Fampidirana

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity K2 CP 10 kW wood stove. Please read these instructions carefully before using the appliance and retain them for future reference. Proper adherence to these guidelines will ensure optimal performance and longevity of your stove.

Prity K2 CP Wood Stove with fire burning in the combustion chamber

Sary 1: Eo anoloana view of the Prity K2 CP wood stove with a visible fire through the ceramic glass door.

1.1 Ny vokatraview

The Prity K2 CP is a 10 kW wood-burning stove designed for heating residential spaces. It features a robust construction with a reinforced combustion chamber lined with refractory bricks for heat accumulation and improved combustion temperature. The stove is equipped with heat-resistant ceramic glass, a cast iron grate, and two manual dampers for precise air and flame intensity control. An integrated compartment is provided for storing and drying wood.

1.2 Fampahafantarana momba ny fiarovana

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

  • Ataovy izay hahazoana rivotra tsara ao amin'ny efitrano misy ny fatana.
  • Maintain required clearances to combustible materials as specified in local building codes and this manual.
  • Only use recommended fuels (wood, coal). Do not burn plastics, treated wood, or other unsuitable materials.
  • Regularly inspect and clean the flue system to prevent creosote buildup and chimney fires.
  • Keep children and pets away from the hot surfaces of the stove.
  • Install smoke and carbon monoxide detectors in your home.

2. Fametrahana sy fametrahana

Installation must be performed by a qualified professional and comply with all local and national building and fire safety regulations.

2.1 Famoahana sy fisafoana

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately. Ensure all components listed in the packing list are present.

2.2 Toerana sy fanala

Choose a suitable location for the stove, ensuring it is on a non-combustible floor or hearth. Maintain the minimum clearances to combustible walls and materials as specified by local regulations and the manufacturer. The flue pipe connection is at the top of the stove.

Prity K2 CP Wood Stove with Ecodesign 2022 and Blm SchV2 labels

Image 2: Prity K2 CP wood stove displaying Ecodesign 2022 and Blm SchV2 certifications, indicating compliance with environmental standards.

2.3 Flue System Connection

Connect the stove to a suitable chimney or flue system with a diameter of 130 mm. Ensure all connections are sealed properly to prevent smoke leakage. The chimney must be in good condition, free of obstructions, and capable of providing adequate draft.

2.4 Initial Firing (Curing)

Before regular use, the stove must be cured to allow the paint and internal components to settle. This process involves several small, low-temperature fires. During curing, some smoke and odor may be emitted; ensure the area is well-ventilated. Avoid high temperatures during the first few fires.

3. Torolàlana miasa

Understanding how to properly operate your Prity K2 CP stove is crucial for safety, efficiency, and comfort.

3.1 Fuel Type

The Prity K2 CP stove is designed to burn wood and coal. For optimal performance and to minimize creosote buildup, use dry, seasoned hardwood. Wood with a moisture content of 20% or less is recommended. Avoid burning:

  • Hazo lena na tsy misy tsirony
  • Garbage, plastics, or chemical waste
  • Hazo voatsabo na voaloko
  • ranon-javatra mirehitra

3.2 Mandrehitra ny fatana

  1. Open both the front air supply damper and the smoke damper fully.
  2. Place crumpled paper or natural firelighters on the cast iron grate.
  3. Add a small amount of kindling (small, dry pieces of wood) on top of the firelighters.
  4. Light the firelighters.
  5. Rehefa mirehitra tsara ny kitay dia ampio tsikelikely ireo kitay lehibe kokoa.
  6. Close the combustion chamber door once the fire is established.

3.3 Fanaraha-maso ny rivotra

The stove is equipped with two manual dampers:

  • Front Air Damper: Located at the front, this controls the primary air supply to the combustion chamber. Open it for ignition and when adding new fuel. Close it partially to reduce the burn rate and conserve fuel.
  • Setroka Damper: This regulates the intensity of the flame and the draft through the flue. Adjust it to achieve a steady, efficient burn.

Adjusting these dampers allows you to control the heat output and efficiency. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or wet fuel.

3.4 Fandotoana

When adding more fuel, open the front air damper and smoke damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Carefully place new logs onto the existing embers and close the door. Adjust the dampers once the new fuel has ignited.

4. Fikojakojana

Regular maintenance is essential for the safe and efficient operation of your Prity K2 CP stove.

4.1 Fanalana lavenona

Remove ash regularly from the ash pan, typically when it is about two-thirds full. Do not allow ash to build up and touch the bottom of the grate, as this can restrict airflow and damage the grate. Always use a metal container with a tight-fitting lid for ash disposal, as embers can remain hot for days.

4.2 Fanadiovana fitaratra

The ceramic glass in the combustion chamber door can become dirty with soot. Clean it when the stove is cold using a specialized glass cleaner for wood stoves or a damp cloth dipped in ash. Avoid abrasive cleaners or tools that could scratch the glass.

4.3 Flue and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type. Creosote buildup is a fire hazard. This task should be performed by a certified chimney sweep.

4.4 Fanaraha-maso ankapobeny

Periodically check the door seals for wear and tear. Replace them if they are damaged to ensure an airtight seal. Inspect the refractory bricks for cracks or damage; while minor cracks are normal, severely damaged bricks should be replaced.

5. Famahana olana

This section addresses common issues you might encounter with your wood stove.

OLANAAntony mety hitrangavahaolana
Setroka miditra ao amin'ny efitranoInsufficient draft, blocked chimney, opening door too quickly, wet fuel.Check chimney for blockages, ensure dampers are open, pre-heat flue, use dry fuel, open door slowly.
Faharatsian'ny hafananaWet fuel, insufficient air, stove too small for space, excessive ash.Use dry fuel, adjust air dampers, remove ash, ensure stove size is appropriate.
Rapid burning of fuelToo much air supply, faulty door seal.Rivotra akaiky dampers partially, check and replace door seals if necessary.
Mihamainty haingana ny fitaratraWet fuel, low burning temperature, insufficient air wash.Use dry fuel, ensure adequate air supply, clean glass regularly.

6. Famaritana

Technical data for the Prity K2 CP 10 kW Wood Stove.

endri-javatrasarobidy
MarikaPrity (BALKAN ENERGY)
MODELYK2 CP
Haben'ny vokatra (H x W x D)810 x 500 x 510 mm
Combustion Chamber Dimensions (H x W x D)400 x 365 x 410 mm
Hery fanafanana10 kW
Faritra ambonin'ny fanafananaApprox. 57 m²
fahombiazana75-80%
Savaivony fantsona fantsona130 mm
Toetran'ny flueTop
Karazana solikaWood, Coal
KEVITRAStainless Steel (Body), Cast Iron (Grate, Top Plate), Ceramic Glass
lokoMainty grika
lanja90 kg
Kilasy angovoA
CertificationCE, EN Standard
Laharana fisoratana anarana EPREL1271282

7. Warranty sy fanohanana

For warranty information, technical support, or spare parts, please contact the manufacturer or your retailer.

Please have your model number (K2 CP) and purchase date available when contacting support.

Documents mifandraika - K2 CP

Preview Prity Boilers: Technical Description, Installation, and Operation Manual
Comprehensive guide for Prity residential boilers, covering technical specifications, installation procedures, operation instructions, maintenance, and troubleshooting for solid fuel and pellet models.
Preview Truma Combi (E) Operating Instructions and Technical Guide
Comprehensive operating instructions and technical specifications for the Truma Combi (E) caravan and motorhome heater. Covers installation, operation, safety, maintenance, troubleshooting, and warranty information.
Preview Lochinvar Copper-Fin II Commercial Pool Heater CP-SPEC-10 Technical Specifications
Detailed technical specifications for the Lochinvar Copper-Fin II commercial pool heater, model CP-SPEC-10, covering features, construction, controls, and certifications for pool and spa applications.
Preview Truma CP plus Torolàlana momba ny fampandehanana sy Torolàlana momba ny famahana olana
Torolàlana fampandehanana feno sy torolalana famahana olana ho an'ny Truma CP plus tontonana fanaraha-maso, mandrakotra ny fametrahana, ny fampandehanana, ny fiasa ary ny fitiliana ny lesoka ho an'ny fanafanana entona Combi sy diesel, ary koa ny rafitra fanamafisam-peo.
Preview Truma AquaGo Decalcification Instructions and Maintenance Guide
Detailed instructions for decalcifying your Truma AquaGo RV water heater. This guide covers procedures for both Analog Dial and CP plus controller models, including troubleshooting steps for common issues like being stuck in clean mode.