Please read this manual carefully before operating your AireMax APH10CE Portable Air Conditioner. Keep these instructions for future reference. Failure to follow these instructions may result in electric shock, fire, or personal injury.
- Always connect the unit to a properly grounded 115V/60Hz electrical outlet.
- Aza miasa amin'ny tady na plug simba ny fitaovana.
- Do not block air inlets or outlets. Ensure at least 12 inches (30 cm) of clearance around the unit for proper airflow.
- Aza mampiditra rantsantanana na zavatra vahiny ao anatin'ny lavaka fivoahan'ny rivotra.
- Aza ampiasaina akaikin'ny entona mora mirehitra na zavatra mora mirehitra ny fitaovana.
- Esory foana ny plug alohan'ny hanadiovana na hanaovana fikojakojana.
- Ity fitaovana ity dia tsy natao hampiasain'ny olona (anisan'izany ny ankizy) manana fahasahiranana ara-batana, ara-pihetseham-po na ara-tsaina, na tsy fahampian'ny traikefa sy fahalalana, raha tsy hoe nomena fanaraha-maso na toromarika mikasika ny fampiasana ny fitaovana avy amin'ny olona iray tompon'andraikitra amin'ny fiarovana azy ireo.
- Tokony hojerena ny ankizy mba hahazoana antoka fa tsy milalao amin'ny fitaovana izy ireo.
2. Vokatra mihoatraview
The AireMax APH10CE is a portable air conditioner designed to provide efficient cooling and dehumidification for spaces up to 600 square feet (approximately 55 m²). It features a self-evaporative system, three fan speeds, and a sleep function for enhanced comfort.

Sary 2.1: anoloana view of the AireMax APH10CE Portable Air Conditioner. This image shows the sleek, white design of the unit with the AireMax logo prominently displayed at the top.

Sary 2.2: zorony view of the AireMax APH10CE Portable Air Conditioner. This perspective highlights the side vents and the overall compact design, suitable for various room settings.
Takelaka fikirakirana

Sary 2.3: Close-up of the AireMax APH10CE control panel. The panel features an LED display and touch buttons for various functions including Timer, Fan speed, Temperature Up/Down, Mode, and Power.

Sary 2.4: Diagram illustrating the functions of the Digital LED Display Panel. It shows controls for Timer (24 hours auto on/off), Fan (High, Med, Low speeds), Up/Down buttons for temperature (62.6°F - 86°F), Mode (Cooling, Dehumidifying, Fan), and Power. Indicators for "Full" (water tank) and "Sleep" mode are also visible.
aoriana View ary Components

Sary 2.5: aoriana view of the AireMax APH10CE with key components labeled. This includes the Filter Frame, Dust Removing Filter, Exhaust Connector, and Double Drainage Hoses, indicating options for water removal.

Sary 2.6: aoriana view of the AireMax APH10CE, providing a clearer look at the air vents and the integrated power cord storage area, designed for neat organization when not in use.
3. Anisan'izany ny singa
Your AireMax APH10CE Portable Air Conditioner package should contain the following items:
- AireMax APH10CE Portable Air Conditioner Unit
- Fanaraha-maso lavitra
- Batterie (ho an'ny fanaraha-maso lavitra)
- Window Kit (for exhaust hose installation)
- Hose setroka
- Round Connector
- adaptatera
- Torolàlana ho an'ny tompony (ity antontan-taratasy ity)
- Warranty Information
If any components are missing or damaged, please contact AireMax customer support.
4. Fametrahana sy fametrahana
Tena ilaina ny fanamboarana mety amin'ny fampandehanana tsara ny air conditioner portable anao.
4.1 Fametrahana vondrona
- Apetraho amin'ny faritra fisaka sy milamina ilay singa.
- Ataovy azo antoka fa farafahakeliny 12 santimetatra (30 sm) ny habaka manodidina ny fitaovana mba hivezivezena tsara ny rivotra.
- Position the unit near a window or sliding door for exhaust hose installation.
- The unit is designed for rooms up to 600 sq ft (approx. 55 m²).
- The unit is equipped with 4-direction casters and side handles for easy transport within your home.
4.2 Fametrahana Kit Window
The window kit allows you to vent the hot air outside, which is essential for effective cooling.
- Assemble the window kit components according to the diagrams provided in the separate window kit instructions (if applicable) or by connecting the adapter to the exhaust hose.
- Extend the window kit to fit your window opening. Secure it in place.
- Attach the exhaust hose to the unit's exhaust connector (refer to Figure 2.5).
- Connect the other end of the exhaust hose to the adapter in the window kit.
- Ensure all connections are secure to prevent hot air from re-entering the room.
4.3 Drainage Setup
The AireMax APH10CE features a self-evaporative system, which typically means most condensed water is recycled for cooling and expelled with the exhaust air. However, in high humidity conditions, manual drainage may be required.
- For continuous drainage (especially in dehumidifier mode or high humidity), connect a drainage hose (not always included, check components list) to one of the double drainage hoses outlets at the rear of the unit (refer to Figure 2.5).
- Route the hose to a floor drain or a suitable collection container.
- Ensure the hose is sloped downwards to allow gravity drainage.
- The unit has a "Water tank full reminder" indicator on the control panel (Figure 2.4). When this illuminates, the unit will stop operating until the water tank is drained manually.
5. Torolàlana miasa
Familiarize yourself with the control panel (Figure 2.3 and 2.4) and remote control for optimal operation.
5.1 Power On/off
- Tsindrio ny fahefana bokotra eo amin'ny tontonana fanaraha-maso na fanaraha-maso lavitra mba hamelomana na hamono ilay fitaovana.
5.2 Fomba Fifantenana
Tsindrio ny MODE bokotra imbetsaka hivezivezy amin'ny fomba misy:
- Fomba fampangatsiahana: For air conditioning. Set your desired temperature using the AVY AVY buttons. The temperature range is 62.6°F (17°C) to 86°F (30°C).
- Fomba fanesorana hamandoana: For removing excess moisture from the air. The unit can remove up to 90 pints of moisture per day. Fan speed is typically fixed in this mode.
- Fomba mpankafy: For air circulation without cooling. You can adjust the fan speed.
5.3 Fanitsiana ny hafainganan'ny mpankafy
Ao amin'ny mode Cooling na Fan, tsindrio ny Fan button to select between High, Medium, or Low fan speeds.
5.4 Famantarana asa
The timer allows you to set the unit to automatically turn on or off after a specified period (up to 24 hours).
- Rehefa mandeha ny unit, tsindrio ny fameram-potoana bokotra.
- Ampiasao ny AVY AVY buttons to set the desired number of hours for the unit to turn off.
- Rehefa tapaka ilay fitaovana dia tsindrio ny fameram-potoana bokotra.
- Ampiasao ny AVY AVY buttons to set the desired number of hours for the unit to turn on.
5.5 Fametrahana torimaso
The Sleep function is designed for comfortable overnight operation in cooling mode. It gradually increases the set temperature by a few degrees over several hours to save energy and prevent overcooling.
- Activate the Sleep function by pressing the dedicated button on the remote control (if available) or by selecting it via the control panel (refer to Figure 2.4 for indicator).
5.6 Famerenana mandeha ho azy
The unit features an automatic restart function. In case of a power outage, hiverina ho azy amin'ny fiasany farany ilay fitaovana rehefa miverina amin'ny laoniny ny herinaratra.
6. Fikojakojana
Regular maintenance ensures optimal performance and extends the lifespan of your AireMax APH10CE.
6.1 Fanadiovana ny sivana rivotra
The unit is equipped with removable mesh filters (refer to Figure 2.5). Clean them regularly, especially if the unit is used frequently.
- Esory ny fantson-drivotra amin'ny fivoahan'ny herinaratra.
- Locate and remove the filter frame from the rear of the unit.
- Gently remove the mesh filter from the frame.
- Vacuum any loose dust from the filter.
- Wash the filter under warm, running water with a mild detergent if necessary.
- Rinse thoroughly and allow the filter to air dry completely before reinserting it.
- Reinstall the filter into the frame and then back into the unit.
6.2 Draining Accumulated Water
While the unit has a self-evaporative system, manual drainage may be necessary if the "Water tank full reminder" indicator illuminates.
- Esory ny fantson-drivotra.
- Place a shallow pan or tray beneath the drainage outlet(s) at the rear of the unit.
- Remove the drain plug(s) to allow water to flow out.
- Once all water has drained, replace the drain plug(s) securely.
6.3 Fanadiovana ny ivelany amin'ny fitaovana
- Fafao ny ivelan'ny fitaovana amin'ny malefaka, damp lamba.
- Aza mampiasa akora simika mahery vaika, abrasive, na solvent.
6.4 Fitehirizana
Raha mitahiry ilay fitaovana mandritra ny fotoana maharitra:
- Drain all accumulated water completely.
- Diovy ny sivana rivotra.
- Store the power cord neatly in its designated storage area (Figure 2.6).
- Tehirizo ao amin'ny toerana mangatsiatsiaka sy maina ny fitaovana, lavitry ny tara-masoandro mivantana sy ny hafanana tafahoatra.
7. Famahana olana
Alohan'ny hifandraisana amin'ny fanohanan'ny mpanjifa dia jereo ity torolalana famahana olana manaraka ity ho an'ny olana mahazatra.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy mandeha ny unit. | No power supply; Power cord not plugged in; Circuit breaker tripped; Water tank full. | Ensure unit is plugged into a live 115V/60Hz outlet; Check circuit breaker; Drain water tank if "Full" indicator is on. |
| Mandeha ny fitaovana fa tsy mangatsiaka. | Air filter clogged; Exhaust hose not properly installed or blocked; Room too large; Doors/windows open; Temperature setting too high. | Clean air filter; Check exhaust hose for proper installation and obstructions; Close doors and windows; Lower temperature setting. |
| "Full" indicator is on. | Feno ny fitoeran-drano. | Drain the water tank as described in Section 6.2. |
| Mitabataba ny unit. | Unit not on a level surface; Fan speed too high; Obstruction in fan. | Place unit on a level surface; Reduce fan speed; Check for obstructions. (Note: Normal operating noise level is 64 dB). |
| Tsy mandeha ny fanaraha-maso lavitra. | Batterie maty na diso nampidirina; Sakantsakana eo anelanelan'ny lavitra sy ny unit. | Replace batteries; Ensure line of sight to unit's receiver. |
8. Famaritana
Detailed technical specifications for the AireMax APH10CE Portable Air Conditioner.

Sary 8.1: Diagram showing detailed parameters and dimensions of the AireMax APH10CE. This includes cooling capacity, power supply, dehumidifying capacity, and physical dimensions.
| fikirana | sarobidy |
|---|---|
| Laharana modely | APH10CE |
| Fahafahana mangatsiaka (SACC) | 10,000 BTU |
| Fahafahana mangatsiaka (ASHRAE) | 15,000 BTU |
| Tombanana ho faritra mangatsiaka | Up to 600 sq ft (approx. 55 m²) |
| Herin'aratra | 115V / 60Hz |
| Fanjifana herinaratra naoty | 1300W / 11.6A |
| Fahaiza-manafoana | 90 pints/andro |
| Ambaratonga tabataba | 64 dB |
| refy (L x W x H) | 16.54 x 17.64 x 30.39 santimetatra (42.01 x 44.81 x 77.19 cm) |
| Lanja iray | 72.5 lbs (32.89 kg) |
| Endri-javatra manokana | Dehumidifier, Rapid Cooling, Auto-evaporation, Auto restart after power failure |
| Air Louvers | Lalana roa mandeha ho azy |
| Drainage | Etona mandeha ho azy na tanana |
9. Warranty sy fanohanana
Your AireMax APH10CE Portable Air Conditioner comes with a manufacturer's warranty. Please refer to the separate warranty information included in your package for details on coverage and terms.
For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact AireMax customer support. Contact information can typically be found on the product packaging, the official AireMax website, or the warranty document.
Please have your model number (APH10CE) and purchase date ready when contacting support.