FireAngel FA6120-INT

FireAngel FA6120 Optical Smoke Alarm User Manual

Model: FA6120-INT

1. Fampidirana

This manual provides essential information for the proper installation, operation, and maintenance of your FireAngel FA6120 Optical Smoke Alarm. The FA6120 is designed for early detection of slow-burning fires, featuring an advanced optical sensor and a sealed 10-year battery for continuous protection. It serves as a direct replacement for older FireAngel ST-622/ST-620 models.

2. Vokatra mihoatraview

The FireAngel FA6120 is a compact, optical smoke alarm engineered for reliable home fire safety. Its key features include:

  • Optical Sensor: Detects smoke from slow-burning fires, reducing false alarms from cooking fumes.
  • Batterie voaisy tombo-kase 10 taona: Provides continuous power for the entire lifespan of the alarm, eliminating the need for battery replacement.
  • Bokotra fitsapana/fanginana: Allows for easy testing of the alarm's functionality and temporary silencing of nuisance alarms or low battery warnings.
  • Sleep Easy™ Function: Temporarily silences low battery warnings for 8 hours, ideal for nighttime alerts, while maintaining smoke detection capability.
FireAngel FA6120 Optical Smoke Alarm front view

Sary 1: anoloana view of the FireAngel FA6120 Optical Smoke Alarm, showing the central test/silence button and FireAngel branding.

3. Information momba ny fiarovana

Zava-dehibe ny fiarovanao. Araho ireto torolalana manaraka ireto azafady:

  • The FA6120 smoke detector is CE marked and certified to EN 14604:2005+AC:2008 standards, and carries the Q-label, ensuring high safety and performance.
  • The integrated battery is sealed and non-replaceable. Do not attempt to open the unit or replace the battery.
  • Avoid placing the alarm near bathrooms or kitchens, as steam and cooking fumes can trigger nuisance alarms.
  • Regularly test your smoke alarm as described in the Operating Instructions section.

4. Fametrahana sy fametrahana

The FireAngel FA6120 is designed for easy installation. Follow these steps to properly mount your smoke alarm:

  1. Mifidiana toerana: Select a suitable location on the ceiling, ensuring it is at least 300 mm (12 inches) away from luminaires (light fixtures) and walls. Smoke alarms are suitable for habitable recreational vehicles. Do not install in kitchens or bathrooms due to potential nuisance alarms from steam or cooking fumes.
  2. Tendrombohitra Base Plate: Use the provided screws (not supplied with the alarm, typically standard mounting screws) to fix the removable base plate securely to the ceiling. The base plate is identical to that of the ST622 model, allowing for easy replacement.
  3. Ampifandraiso ny fanairana: Once the base plate is mounted, push the smoke alarm onto the base plate and turn it clockwise until it clicks firmly into place.
Installation steps for FireAngel FA6120 smoke alarm

Sary 2: Visual guide for installing the FireAngel FA6120, showing the removable base plate and the twist-on attachment method.

Placement guidelines for FireAngel smoke alarms

Sary 3: Illustration of recommended placement, indicating a minimum distance of 300mm from walls and light fixtures, suitability for RVs, and unsuitability for kitchens/bathrooms.

5. Torolàlana miasa

Understanding how to operate your smoke alarm ensures its effectiveness.

5.1. Fitsapana ny Fanairana

To ensure your alarm is functioning correctly, press and hold the large central Test/Silence button. A loud alarm sound will confirm its proper operation. Test your alarm weekly.

5.2. Silencing Nuisance Alarms

In the event of a false alarm (e.g., from cooking fumes or steam), press the Test/Silence button to temporarily silence the alarm for 10 minutes. Ensure the cause of the false alarm is identified and resolved.

5.3. Sleep Easy™ Function

If a low battery alert sounds during the night, you can activate the Sleep Easy™ function. Press the Test/Silence button to silence the low battery chirp for 8 hours. The red LED will continue to flash, indicating the low battery status. The alarm will still detect smoke during this period. Remember to replace the alarm within 30 days of the first low battery alert, as the battery is sealed and non-replaceable.

6. Fikojakojana

Proper maintenance helps ensure the longevity and reliability of your smoke alarm.

  • Fitsapana isan-kerinandro: Test your smoke alarm weekly by pressing the Test/Silence button.
  • Fanadiovana: Gently vacuum the alarm's casing once a month using a soft brush attachment to remove dust and cobwebs. Do not use cleaning solvents or sprays.
  • Batterie: The alarm features a sealed 10-year lithium battery that does not require replacement. When the alarm reaches the end of its 10-year lifespan or consistently indicates a low battery, the entire unit must be replaced.

7. Famahana olana

Jereo ny tabilao etsy ambany ho an'ny olana mahazatra sy ny vahaolana:

OLANAAntony mety hitrangavahaolana
Maneno tsy tapaka na tsy misy antony mazava ny fanairana.Nuisance alarm from steam, cooking fumes, or dust.Press the Test/Silence button to silence for 10 minutes. Clean the alarm. Relocate if consistently triggered by environmental factors.
Alarm chirps periodically (e.g., every 30-60 seconds).Fampitandremana bateria kely.If at night, use Sleep Easy™ function. Replace the entire alarm unit within 30 days.
Alarm does not sound when Test button is pressed.Alarm malfunction or end of life.Ensure the alarm is correctly mounted. If still unresponsive, replace the unit immediately.

8. Famaritana

endri-javatraantsipirihany
Laharana modelyFA6120-INT
MarikaFireAngel
Karazana sensorOptical
Loharanon-kerySealed Lithium Battery (1 CR123A equivalent)
Fiainana bateria10 Years (non-replaceable)
Ambaratonga feo fanairana85 dB(A) amin'ny 3 metatra
refy (H x D)3.15sm x11.81sm
lanja138g ny
KEVITRAplastika
CertificationsCE, EN 14604:2005+AC:2008, Q-label
Anisan'ny singa1 x Baseplate, 1 x Instruction Manual, 1 x Optical Smoke Alarm with Sealed Lithium Battery

9. Warranty sy fanohanana

The FireAngel FA6120 Optical Smoke Alarm comes with a 1-year availability for spare parts, as per EU regulations. For specific warranty details, technical support, or further assistance, please refer to the contact information provided in the packaging or visit the official FireAngel website. Always ensure you have your model number (FA6120-INT) ready when contacting support.

Documents mifandraika - FA6120-INT

Preview FireAngel Smoke and Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
User manual for FireAngel Optical Smoke Alarms (FA6611, FA6615, FA6620) and Heat Alarms (FA6720). Provides detailed information on positioning, installation, maintenance, troubleshooting, silence and sleep easy features, warranty, and disposal instructions for ensuring home fire safety.
Preview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Preview FireAngel ST-625-INT Smoke Alarm User Manual
Comprehensive user manual for the FireAngel ST-625-INT smoke alarm, covering installation, features, maintenance, and warranty. This guide provides essential safety information and operational instructions.
Preview FireAngel ST-622-BNLT Optical Smoke Detector - Bateria 10 taona
Famaritana amin'ny antsipiriany sy famaritana ny vokatra ho an'ny mpitsikilo setroka optika FireAngel ST-622-BNLT. Manana bateria maharitra 10 taona, teknolojia Thermoptek, Smart Silence, ary efitrano mahatohitra bibikely. Fantaro ny antsipiriany ara-teknika sy ny advantages.
Preview FireAngel Smoke & Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
Comprehensive user manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Covers installation, maintenance, troubleshooting, warranty, and disposal.
Preview Boky Torolàlana ho an'ny Mpampiasa Fanairana Setroka Tsy Misy Tariby FireAngel WST-630N
Boky torolalana feno ho an'ny fampiasana ny fanairana setroka tsy misy tariby FireAngel WST-630N. Mianara momba ny teknolojia, ny fametrahana, ny fampiasana ary ny endri-javatra fiarovana Thermoptek mba hahazoana antoka ny fitadiavana afo ao an-trano.