Fitnet AL-300L

Fitnet AL-300L 79 Gallon Aquarium Chiller Instruction Manual

Model: AL-300L

1. Fampidirana

This manual provides detailed instructions for the safe and efficient operation of your Fitnet AL-300L Aquarium Chiller. This unit is designed to maintain optimal water temperatures for various aquatic environments, including freshwater and saltwater aquariums, as well as hydroponic systems. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.

Fitnet AL-300L Aquarium Chiller main unit

Figure 1: Fitnet AL-300L Aquarium Chiller. This image shows the main chiller unit with its digital display and water inlet/outlet nozzles.

Endriky ny vokatra:

Image showing the chiller being used for both hydroponic systems and fish tanks

Figure 2: Versatile applications. This image illustrates the chiller's suitability for both hydroponic systems (top) and traditional fish tanks (bottom).

2. Information momba ny fiarovana

Please observe the following safety precautions to prevent injury or damage to the product.

Diagram showing recommended 6 inch clearance around chiller for heat dissipation

Figure 3: Recommended clearance for heat dissipation. This diagram illustrates the importance of maintaining at least 6 inches (15 cm) of space between the chiller and any walls or obstructions to ensure proper airflow and cooling efficiency.

3. Ny votoatin'ny fonosana

Hamarino tsara fa ao anaty fonosana avokoa ny entana rehetra alohan'ny hanombohana ny fametrahana.

Image showing all components included with the Fitnet Aquarium Chiller

Figure 4: Included components. This image displays the main chiller unit alongside the water pump, hoses, connectors, and clamps that come with the product.

Close-up of the submersible water pump included with the chiller

Figure 5: Submersible water pump. This image shows the water pump, designed for submersion in fresh or saltwater, which circulates water through the chiller.

4. Torolàlana fananganana

Follow these steps for proper installation of your aquarium chiller.

  1. Positioning the Chiller: Place the chiller on a flat, stable surface near your aquarium or hydroponic system. Ensure there is at least 6 inches (15 cm) of clear space around all sides for optimal airflow and heat dissipation.
  2. Prepare Connectors: Gather the provided connectors, including the white sealing washers.
  3. Install Inlet/Outlet Nozzles:
    • Insert a white sealing washer onto each inlet/outlet nozzle.
    • Place the pipe joint into the black nut cap.
    • Tighten the black nuts onto the chiller's inlet and outlet ports.
  4. Connect Water Pump: Attach one end of the water pipe to the outlet of the submersible water pump. Secure it with a clamp raha ilaina.
  5. Connect Chiller to System:
    • Connect the other end of the water pipe from the pump to the chiller's inlet port.
    • Connect a second water pipe from the chiller's outlet port back to your aquarium or hydroponic system.
    • Ataovy azo antoka fa mafy tsara ary tsy tantera-drano ny fifandraisana rehetra mba hisorohana ny fivoahan'ny rano.
  6. Paompy manondraka: Place the submersible water pump into your aquarium or hydroponic reservoir. Ensure it is fully submerged and positioned to draw water effectively.
  7. Fampifandraisana herinaratra: Plug the chiller's power cord into a GFCI-protected electrical outlet. Plug in the water pump's power cord.
Step-by-step diagram for connecting the chiller hoses and pump

Figure 6: Chiller installation steps. This diagram illustrates the process of preparing accessories, installing sealing washers, attaching pipe joints, and tightening the black nuts for secure hose connections.

Fitnet Aquarium Chiller connected to a fish tank, showing dimensions

Figure 7: Chiller setup with an aquarium. This image shows the chiller unit connected to a small fish tank, illustrating the hose routing and the overall footprint of the chiller (dimensions: 12.6" H x 11.4" W x 11.4" D).

5. Torolàlana miasa

The chiller features a digital control panel for temperature setting and calibration.

5.1. Power On/off

Locate the power switch on the back of the unit. Flip the switch to the 'ON' position to power on the chiller. The digital display will illuminate.

Close-up of the power switch on the back of the chiller unit

Figure 8: Power switch. This image shows the main power switch located on the rear panel of the chiller unit.

5.2. Temperature Setting (Assumed Target Temperature Range: 75-79°F)

The chiller will begin cooling after a 2-3 minute power-on delay. To adjust the target temperature:

  1. Set Shutdown Temperature: Tsindrio ny Set fanalahidy. Ampiasao ny (ambony) na (down) arrow keys to adjust the desired shutdown temperature (e.g., 77°F). Press the voalohany lakile hitahiry.
  2. Set Starting Temperature (F1 Code): Tsindrio lava ny Set fanalahidy hatramin'ny F1 code appears. Then, press the Set key again. Use the or arrow keys to adjust the temperature difference (e.g., to 4°F for a working range of 4°F).
Diagram showing temperature setting and calibration steps on the chiller's control panel

Figure 9: Temperature setting and F2 calibration. This image provides a visual guide to setting the shutdown temperature and adjusting the F1 code for the working temperature range, as well as the F2 calibration process.

5.3. F2 Calibration Setting

If the chiller's displayed temperature does not match an external thermometer, you can calibrate it:

  1. Tsindrio lava ny Set lakile haseho F1. Tsindrio ny lakile haseho F2. mpanao gazety Set indray.
  2. Ampiasao ny or arrow keys to adjust the offset value (e.g., to 5 if the chiller reads 77°F and the actual temperature is 72°F, meaning a -5 adjustment is needed). Press voalohany mba hiverina amin'ny fampisehoana maripana ankehitriny.

6. Fikojakojana

Regular maintenance ensures optimal performance and extends the lifespan of your chiller.

7. Famahana olana

If you encounter issues with your chiller, refer to the following common problems and solutions.

OLANAAntony mety hitrangavahaolana
Chiller not cooling or insufficient cooling.
  • Insufficient airflow around the unit.
  • Water pump not operating or clogged.
  • Ambient room temperature too high.
  • Water volume too large for chiller capacity.
  • Diso ny fikirana mari-pana.
  • Ensure 6 inches (15 cm) clearance around the chiller.
  • Check pump for power and blockages; clean if necessary.
  • Reduce room temperature or consider a higher capacity chiller.
  • Reduce water volume if possible, or allow more time for cooling.
  • Verify temperature settings (Section 5.2).
Ny rano mitete avy amin'ny fifandraisana.
  • Fifandraisana hose malalaka.
  • Damaged sealing washers or hoses.
  • Henjana daholo ny fantsona clamps sy fifandraisana.
  • Inspect and replace any damaged washers or hoses.
Chiller making unusual noise.
  • Vibrations from compressor (normal to some extent).
  • Fansakana.
  • Unit tsy niveau.
  • Ensure unit is on a stable, level surface.
  • Check fan vents for obstructions and clean if necessary.
  • Some compressor noise is normal; ensure it's not excessive.
Digital display shows incorrect temperature.
  • Ilaina ny calibration.
  • Perform F2 calibration as described in Section 5.3.

8. Famaritana

endri-javatraantsipirihany
Anarana modelyAL-300L
fahafahana79 galona / 300 litatra
refy (L x W x H)12.6 x 11.4 x 11.39 santimetatra
refrigerantR134a
Temperature Recommended68°F - 79°F (20°C - 26°C)
KEVITRAVIRATY
lokoMainty
mpanamboatrafitnessnet
Pump Power (Qmax)15W, 600L/H
BOKYtage110V/60HZ

9. Warranty sy fanohanana

Fitnet offers a 1 taona ny antoka mpanamboatra for this 79-gallon water chiller. This warranty covers defects in materials and workmanship under normal use.

For warranty claims, technical support, or any questions regarding your Fitnet Aquarium Chiller, please contact Fitnet customer service through your original purchase platform or the official Fitnet website.

Azafady, tehirizo ny porofon'ny fividiananao mba hanamarina ny fiantohana.

Documents mifandraika - AL-300L

Preview Poafamx Aquarium Water Chiller 42GAL/160L AL-160G Torolàlana
Torolàlana ho an'ny Poafamx AL-160G Aquarium Water Chiller (42GAL/160L). Mianara momba ny fametrahana, ny fandidiana, ny masontsivana ary ny famahana olana amin'ny fitazonana ny mari-pana tsara indrindra amin'ny aquarium sy ny rafitra hydroponic.
Preview Baoshishan Aquarium Water Chiller Handling Instructions
This document provides handling instructions for Baoshishan Aquarium Water Chillers, covering introduction, safety precautions, parameters, installation, testing, temperature settings, cleaning, maintenance, and troubleshooting for models AL-60, AL-160, and AL-300.
Preview Torolàlana momba ny fampiasana ny paompin-drano/sivana: Torolàlana momba ny fiarovana sy ny fampandehanana
Ity boky torolalana ho an'ny mpampiasa ity dia manome fitandremana ilaina amin'ny fiarovana sy torolalana amin'ny fampandehanana ny paompin-drano azo alentika ampiasaina amin'ny akquarium, dobo ary fampiharana hafa mivezivezy. Izy io dia mirakitra ny torolàlana momba ny fametrahana, ny fampiasana ary ny fikojakojana.
Preview Adam Equipment MDW-300L Health and Fitness Scale with BMI User Manual
User manual for the Adam Equipment MDW-300L Health and Fitness Scale, detailing its features, technical specifications, setup, operation, calibration, user parameters, RS232 communications, error messages, and warranty information.
Preview Kospel SWPC 300L Water Heater Manual
Fametrahana, fampandehanana ary fepetra ara-teknika ho an'ny cylinder rano mafana ao an-trano Kospel SWPC 300L.
Preview Boky Torolàlana ho an'ny Mpampiasa Jiro Aquarium Jebao AL & AK Series - Fametrahana, Toetoetra ary Fanaraha-maso ny App
Boky torolalana feno ho an'ny jiro aquarium Jebao AL sy AK Series. Mirakitra ny fampidirana ny vokatra, ny famaritana, ny fametrahana, ny fametrahana Wi-Fi, ny fampidinana sy ny fanaraha-maso ny fampiharana, ny fomba fiasa ary ny famahana olana.