1. Fampidirana

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Sary 1.1: Eo anoloana view of the Tektronix TBS2074B Digital Oscilloscope.

2. Endri-javatra fototra

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Fametrahana

3.1 Famoahana

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Hery mampifandray

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

aoriana view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Herin'ny voalohany

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Fampandehanana

4.1 User Interface Overview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Fandrefesana fototra

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Fampiasa mandroso

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. fifandraisana

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Sary 5.1: akaiky view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Fikojakojana

6.1 Fanadiovana

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Fitehirizana

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Famahana olana

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

OLANAAntony mety hitrangavahaolana
Tsy misy heryPower cord not connected; Power outlet fault; Internal fuse blownCheck power cord connection; Test power outlet; Contact service for fuse replacement
Tsy misy endrika onjam-peo asehoProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Onja tsy marin-toeranaIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Famaritana

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

famaritanasarobidy
mpanamboatraTektronix
Laharana modelyTBS2074B
passante70 MHz (Upgradeable to 200 MHz with option)
Analog Channels4
Max Sample Rate2 GS/s (half channel), 1 GS/s (all channels)
Haavan'ny firaketana5 isa M
miseho9-inch WVGA Color Display
Fandrefesana mandeha ho azy32 karazana
Probe InterfaceTekVPI
fifandraisanaUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Lanja entana3 kg
Ny haben'ny fonosana50 x 40 x 26 cm
Anisan'ny singaStandard Accessory KIT
Batteries Usedtsy misy
First Available Date (Amazon.co.jp)2020/5/11

9. Warranty sy fanohanana

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support