The Wilo Star S 33 FC 4190420 is a three-speed hydronic radiant floor circulating pump designed for efficient water circulation in various heating applications. Its robust cast iron housing and built-in motor protection ensure long life and reliable performance. This pump is suitable for closed-loop radiant heating, snow melting systems, baseboard, radiator, and fan coil heating applications.

Ny endri-javatra fototra dia ahitana:

2. Information momba ny fiarovana

FAMPITANDREMANA: To reduce the risk of electric shock, consult the instruction manual for proper installation and operation. Always disconnect power before servicing the pump.

TANDREMO: The pump surface can become mafana during operation. Avoid direct contact to prevent burns. Allow the pump to cool before handling or performing maintenance.

3. Vokatra mihoatraview ary Components

Wilo Star S 33 FC Circulating Pump, green cast iron body with black electrical box and control dial.

Figure 1: Wilo Star S 33 FC Circulating Pump. This image shows the main body of the pump, its electrical connection box, and the speed selection dial. The green cast iron housing is visible, along with the product label detailing specifications and warnings.

The Wilo Star S 33 FC pump consists of several key components:

4. Fametrahana sy fametrahana

Proper installation is crucial for the pump's performance and longevity. Refer to local plumbing and electrical codes.

  1. Mametraka: Securely mount the pump using its fixed flanges in the designated location within your hydronic system. Ensure the pump is installed in a horizontal position with the motor shaft horizontal to prevent air pockets.
  2. Plumbing Connections: Connect the system piping to the pump's flanges. Use the provided gaskets (O-rings) to ensure a watertight seal. Avoid overtightening connections.
  3. Wiring elektrika:
    • Ensure the power supply is disconnected before wiring.
    • Connect the pump to a 115-Volt (AC), 60Hz power supply. The pump draws a maximum of 1.5A.
    • Follow the wiring diagram provided inside the electrical connection box.
    • Hamarino tsara ny fanorenan-tany mba hisorohana ny loza elektrônika.
  4. System Filling and Purging: After installation, fill the hydronic system with water and thoroughly purge any air from the system. Air in the system can cause noise and reduce pump efficiency.

5. Torolàlana miasa

The Wilo Star S 33 FC features a three-speed motor, allowing you to adjust the pump's performance to match your system's requirements.

  1. Herim-batana: Once installed and the system is filled, restore power to the pump.
  2. Safidy hafainganam-pandeha: Locate the speed selection dial on the front of the pump (refer to Figure 1). The dial has settings for "max", "3", "2", "1", and "eco".
    • Speed 3 (Max): Provides the highest flow rate and pressure. Power consumption is approximately 202W.
    • Haingana 2: Medium flow rate and pressure. Power consumption is approximately 143W.
    • Speed 1 (Eco): Lowest flow rate and pressure, designed for energy efficiency. Power consumption is approximately 98W.
    Rotate the dial to select the desired speed setting. The optimal speed depends on your specific heating system's design and heat load requirements. Start with a lower speed and increase if insufficient circulation is observed.
  3. Check Valve: The built-in check valve can be removed if not required by your system design. Consult your HVAC professional if unsure.

6. Fikojakojana

The Wilo Star S 33 FC pump is designed for minimal maintenance. However, periodic checks can ensure optimal performance and extend its lifespan.

7. Famahana olana

Jereo eto amin'ity tabilao manaraka ity ny olana mahazatra sy ny mety ho vahaolana.

OLANAAntony mety hitrangavahaolana
Tsy manomboka ny paompyNo power supply; Motor overload; Impeller jammed.Check power connection and circuit breaker; Allow motor to cool; Disconnect power and check for obstructions in impeller.
Fikoriana tsy ampyAir in system; Incorrect speed setting; Clogged filter/piping.Purge air from system; Increase speed setting; Check and clean filters or piping.
Hetsika mitabatabaAir in system; Cavitation; Loose mounting.Purge air from system; Ensure adequate system pressure; Check mounting bolts for tightness.
Miporitsaka ny paompyLoose connections; Damaged gaskets/seals.Tighten connections; Replace gaskets or seals.

If the problem persists after attempting these solutions, contact a qualified service technician or Wilo customer support.

8. Famaritana

toetraantsipirihany
Laharana modely4190420
MarikaWilo
KEVITRAvy
BOKYtage115 Volts (AC)
hatetika60 Hz
Draw ankehitriny Max1.5 Amps
Power Consumption (Speed 3)202 Watts
Power Consumption (Speed 2)143 Watts
Power Consumption (Speed 1/Eco)98 Watts
Lanja entana9.46 kilao (4.3 kilao)
Ny haben'ny fonosana7.4 x 7.24 x 5.12 santimetatra
Classe enclosureCSA enclosure 2
Kilasy insulationKilasy F
Max. Temperature rano230°F (110°C)
Max. Fanerena miasa145 PSI (bar 10)
CertificationsUL/CSA voatanisa

9. Warranty sy fanohanana

Wilo products are manufactured to high standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Wilo website.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Wilo customer service. Contact information can typically be found on the Wilo webtranokala na amin'ny tapakila fividiananao.

Wilo Official Webtranokala: www.wilo.com

Documents mifandraika - 4190420

Preview Wilo-Star RS, RSD, ST, RSG, Fametrahana AC sy Torolàlana momba ny fandidiana
Torolàlana feno momba ny fametrahana, fampandehanana ary fikojakojana ny Wilo-Star RS, RSD, ST, RSG, ary paompy mivezivezy AC. Mandrakotra ny fiarovana, ny fepetra ara-teknika, ny fivoriambe, ny fifandraisana elektrika, ny fampandehanana, ny famahana olana ary ny kojakoja.
Preview Wilo-Star RS, RSD, ST, RSG, AC Circulating Pump Fametrahana sy torolalana momba ny asa
Fametrahana sy toromarika fampandehanana feno ho an'ny Wilo-Star RS, RSD, ST, RSG, ary AC andiana paompy mivezivezy. Mirakitra fampahalalana ankapobeny, torolalana momba ny fiarovana, fitaterana, fitehirizana, famaritana paompy, kojakoja, fivoriambe, fifandraisana elektrika, fampandehanana, fikojakojana, famahana olana ary kojakoja.
Preview Wilo-Star RS, RSD, ST, RSG, AC Circulating Pump Fametrahana sy torolalana momba ny asa
Torolàlana fametrahana sy fampandehanana feno ho an'ny Wilo-Star RS, RSD, ST, RSG, paompy mivezivezy AC, mirakitra fampahalalana ankapobeny, fiarovana, fitaterana, famaritana, fivoriambe, fametrahana, fifandraisana elektrika, fandidiana, fikojakojana ary famahana olana.
Preview Wilo-Yonos PICO: Torolàlana fametrahana sy fampiasana
Torolàlana fohy momba ny fametrahana sy fampiasana ny paompy Wilo-Yonos PICO. Mirakitra ny fiarovana, ny fametrahana ary ny fampiasana ny rafitra fanafanana rano mafana. Azo jerena an-tserasera ny boky torolalana feno.
Preview Wilo-Star-Z 15 Installation and Operating Instructions
This document provides comprehensive installation, operation, and maintenance guidance for the Wilo-Star-Z 15 circulating pump. It includes safety warnings, technical specifications, intended use, troubleshooting steps, and contact information for Wilo USA and Wilo Canada.
Preview Wilo Star Residential Wet Rotor Circulators: Installation and Operating Instructions
Comprehensive installation and operating instructions for Wilo Star Residential Wet Rotor Circulators. Covers safety, technical data, installation, electrical connection, startup, maintenance, and troubleshooting.