Zurn Z7000-HW

Zurn Z7000-HW Temp-Gard Standard Hand/Wall Shower Instruction Manual

Model: Z7000-HW

1. Fampidirana

This instruction manual provides essential information for the proper installation, operation, and maintenance of the Zurn Z7000-HW Temp-Gard Standard Hand/Wall Shower. Please read this manual thoroughly before installation and use to ensure safe and efficient operation. Retain this manual for future reference.

2. Vokatra mihoatraview

The Zurn Z7000-HW Temp-Gard Hand/Wall Shower system is designed for reliable performance in various applications. It features a chrome-plated handheld shower head, a flexible metal hose, and a slide bar for adjustable height.

Zurn Z7000-HW Temp-Gard Hand/Wall Shower System

Figure 1: Complete Zurn Z7000-HW Temp-Gard Hand/Wall Shower System. This image shows the full shower unit, including the handheld shower head, flexible metal hose, supply elbow, and 24-inch slide bar, all in a chrome finish.

Zurn Z7000-HW Shower Head Front View

Sary 2: Eo anoloana view of the Zurn Z7000-HW shower head. This image highlights the adjustable spray pattern settings, including 'Massage' and 'Spray' options, on the chrome-plated handheld shower head.

Zurn Z7000-HW Shower Head on Slide Bar

Sary 3: lafiny view of the Zurn Z7000-HW shower head mounted on the slide bar. This image demonstrates how the shower head is held by the adjustable mount on the 24-inch slide bar, allowing for height customization.

Zurn Z7000-HW Supply Elbow

Figure 4: Close-up of the Zurn Z7000-HW supply elbow with flange. This image shows the wall connection point for the flexible metal hose, featuring a chrome finish.

3. Fametrahana sy fametrahana

Installation of the Zurn Z7000-HW Hand/Wall Shower requires basic plumbing knowledge. It is recommended that installation be performed by a qualified professional to ensure proper function and compliance with local codes.

3.1 Anisan'izany ny singa

3.2 General Installation Steps (Consult a professional for detailed instructions)

  1. Fiomanana: Turn off the main water supply. Clear the installation area.
  2. Mount Supply Elbow: Install the supply elbow to the wall water outlet, ensuring a secure, leak-free connection.
  3. Mount Slide Bar: Secure the 24-inch slide bar to the wall using the provided mounting hardware. Ensure it is level and firmly attached.
  4. Connect Hose: Attach one end of the 60-inch flexible metal hose to the supply elbow and the other end to the handheld shower head.
  5. Place Shower Head: Position the handheld shower head onto the adjustable mount on the slide bar.
  6. Fitsapana: Turn on the water supply and check for leaks. Test the shower head's functionality and spray patterns.

Zava-dehibe: Ensure all connections are tightened appropriately to prevent leaks. Do not overtighten, as this may damage components.

4. Torolàlana miasa

The Zurn Z7000-HW Hand/Wall Shower is designed for user convenience and flexibility.

4.1 Using the Handheld Shower Head

4.2 Adjusting Shower Head Height

The 24-inch slide bar allows for easy height adjustment of the shower head.

5. Fikojakojana

Regular cleaning and maintenance will prolong the life and appearance of your Zurn Z7000-HW shower system.

6. Famahana olana

Refer to the following common issues and their potential solutions:

OLANAAntony mety hitrangavahaolana
Iva ny ranoClogged shower head nozzles; partially closed shut-off valve; mineral buildup in hose.Clean shower head nozzles. Ensure shut-off valves are fully open. Inspect and clean hose.
Fivoahan'ny rano amin'ny fifandraisanaLoose connections; worn washers/gaskets.Tighten connections (do not overtighten). Replace worn washers or gaskets.
Shower Head Not Holding Position on Slide BarMounting knob/lever not tightened sufficiently; worn mount.Ensure the knob/lever on the holder is fully tightened. If worn, contact Zurn support for replacement parts.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Zurn customer support.

7. Famaritana

8. Warranty sy fanohanana

The Zurn Z7000-HW Temp-Gard Standard Hand/Wall Shower comes with a Garantie voafetra 3 taona from the date of purchase. This warranty covers defects in material and workmanship under normal use and service.

For warranty claims, technical assistance, or to purchase replacement parts, please contact Zurn customer support through their official webtranokala na ny fampahafantarana momba ny fifandraisana omena miaraka amin'ny antontan-taratasy fividiananao.

Mpanamboatra: Zurn Industries

Webtranokala: www.zurn.com

Documents mifandraika - Z7000-HW

Preview Zurn AquaSense AV ZEMS-IS Series Automatic Sensor Flushometer Installation, Operation, and Maintenance Manual
Comprehensive guide for Zurn AquaSense AV ZEMS-IS Series automatic sensor-operated exposed flushometers with HW6 Power Converter. Covers installation, operation, maintenance, troubleshooting, and parts breakdown for models ZEMS6000AV-IS (Closet) and ZEMS6003AV-IS (Urinal). Includes specifications, safety information, and parts lists.
Preview ZURN Model AG Air Gap Adaptor Fitting
The ZURN Model AG Air Gap Adaptor Fitting is designed for use with ZURN WILKINS Reduced Pressure Principle Backflow Preventers, ensuring proper drain line installation on horizontal or vertical systems. This document details its specifications, materials, and typical installation requirements.
Preview Zurn Wilkins ZW209FP Pressure Reducing Valve Assembly: Installation, Operation, and Maintenance
Comprehensive guide to the Zurn Wilkins ZW209FP fire protection pressure reducing valve assembly, covering installation, start-up, operation, flow characteristics, and maintenance procedures. Includes detailed instructions for main valve and PV-PRD pilot valve.
Preview Zurn NR3XL Lead-Free Pressure Reducing Valve: Installation, Maintenance, and Repair Guide
Comprehensive guide for the Zurn NR3XL Lead-Free Pressure Reducing Valve, covering installation, inspection, maintenance, repair procedures, and troubleshooting. Includes product specifications and warranty information.
Preview Zurn AquaSense ZER-SM Series Automatic Battery-Powered Flush Valve Manual
Comprehensive manual for Zurn AquaSense ZER-SM series automatic battery-powered flush valves, covering installation, operation, maintenance, troubleshooting, and parts breakdown for models like ZER6000-SM, ZER6200-SM, ZER6003-SM, and ZER6203-SM.
Preview Zurn Smart Occupancy Light (Z-LIGHT-W1) Installation, Operation, and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining the Zurn Smart Occupancy Light (Z-LIGHT-W1). Includes wiring diagrams, parts list, troubleshooting, warranty, and regulatory information for commercial and institutional use.