1. Fampidirana
This manual provides essential instructions for the proper installation, operation, and maintenance of your Gladiator Pump Motor. To ensure optimal performance and longevity, please read this manual thoroughly before installation and keep it for future reference. This motor is designed for heavy-duty applications in various hydraulic systems.
2. Information momba ny fiarovana
WARNING: Improper installation or operation can lead to serious injury or equipment damage.
- Tapaho foana ny herinaratra alohan'ny hanaovana fametrahana, fikojakojana, na famahana olana.
- Ny fametrahana dia tsy maintsy ataon'ny mpiasa mahay ihany.
- Ensure all electrical connections are secure and comply with local codes and regulations.
- Manaova fitaovana fiarovana manokana (PPE) sahaza mandritra ny fametrahana sy fikojakojana.
- Aza ampiasaina ny motera raha simba izy io na raha misy singa tsy ao.
- Refer to the specific equipment's manual (e.g., liftgate, hydraulic unit) for additional safety guidelines.
3. Product Description sy ny endri-javatra
The Gladiator Pump Motor is a robust, high-performance unit designed for demanding hydraulic applications. It features a Counter-Clockwise (CCW) rotation and is equipped with offset switch mounting holes for versatile integration. This motor is built to meet or exceed OEM specifications, ensuring reliable operation.

Sary 1: Main view of the Gladiator Pump Motor. This image shows the overall cylindrical shape and the electrical terminal.
Lafin-javatra fototra:
- Meets or exceeds OEM specifications.
- Counter-Clockwise (CCW) rotation.
- Fanamboarana adidy mavesatra.
- Offset switch mounting holes.
- Slot shaft motor design.
4. Mifanaraka
This Gladiator Pump Motor is compatible with a range of hydraulic systems and applications, including but not limited to:
- Maxon Liftgate systems
- Monarch/Bucher MTE Hydraulics
- Leyman Hydraulic systems
- Wapsa Hydraulic systems
- Blizzard Snow applications
Refer to your specific equipment's manual or consult a qualified technician to confirm compatibility with your existing system.
5. Fametrahana sy fametrahana
Installation of the Gladiator Pump Motor requires technical expertise. It is strongly recommended that installation be performed by a certified professional to ensure correct wiring, mounting, and system integration.
General Installation Steps (Consult a professional):
- Fiomanana: Ensure the vehicle or equipment is powered off and secured. Disconnect the battery to prevent accidental startup.
- Removal of Old Motor: Carefully disconnect electrical leads and mounting hardware from the existing pump motor. Note the orientation and connections for reference.
- Mametraka: Position the new Gladiator pump motor, aligning the shaft and mounting holes. Secure it firmly using appropriate hardware.
- Fifandraisana elektrika: Connect the electrical leads to the motor terminals. Ensure correct polarity (positive to positive, negative to negative) and secure all connections to prevent shorts or loose contacts. This motor features offset switch mounting holes, which may require specific wiring configurations depending on your system.
- Fitsapana: After installation, reconnect the battery. Perform a functional test of the hydraulic system, checking for proper motor operation, fluid leaks, and overall system response.

Sary 2: lafiny view of the Gladiator Pump Motor, showing the mounting points and electrical terminal.
6. Fampandehanana
The Gladiator Pump Motor operates as an integral component of your hydraulic system. Its operation is typically controlled by the system's main control unit or switches.
- Ensure the hydraulic fluid level is correct before operating the system.
- Operate the system according to the instructions provided by the manufacturer of the primary equipment (e.g., liftgate, snow plow).
- Monitor for unusual noises, vibrations, or overheating during operation.

Figure 3: End view of the Gladiator Pump Motor, showing the shaft and mounting points.
7. Fikojakojana
Regular maintenance is crucial for extending the life and ensuring the reliable performance of your pump motor.
- Fanaraha-maso maso: Periodically inspect the motor for any signs of damage, corrosion, or loose connections.
- Fahadiovana: Keep the motor free from dirt, debris, and excessive moisture. A clean motor dissipates heat more effectively.
- Fifandraisana elektrika: Check electrical terminals for tightness and corrosion. Clean as necessary.
- Fluid hidraulika: Ensure the hydraulic system's fluid is clean and at the correct level, as specified by the equipment manufacturer. Contaminated or low fluid can strain the pump motor.
- Serivisy matihanina: For any internal motor issues or complex repairs, consult a qualified service technician.

Sary 4: anatiny view of the Gladiator Pump Motor, showing the windings and armature.
8. Famahana olana
This section provides basic troubleshooting steps for common issues. For complex problems, contact a qualified technician.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy mandeha ny motera | No power, loose electrical connection, faulty switch, motor failure. | Check power supply and circuit breaker. Inspect all electrical connections. Test the control switch. If issues persist, professional diagnosis is needed. |
| Motor runs slowly or weakly | Low voltage, worn brushes (if applicable), hydraulic system issue (e.g., low fluid, clogged filter). | Hamarino fa marina ny voltage supply. Check hydraulic fluid level and filter. Consult a professional for motor internal inspection. |
| Mafana be ny maotera | Overload, insufficient ventilation, continuous operation, internal motor fault. | Reduce load if possible. Ensure adequate airflow around the motor. Allow for cooling periods. If overheating persists, seek professional inspection. |
| Feo tsy mahazatra avy amin'ny motera | Worn bearings, loose components, foreign object interference. | Immediately cease operation. Inspect for loose parts or obstructions. Professional inspection is recommended for internal noises. |
9. Famaritana
The following specifications apply to the Gladiator Pump Motor (Models: 9130450046 W-8945, 39200398, MMY4003, 250093, P33818, 8082, 46-3648, MUJ4001S):
- marika: Gladiator
- Mpanamboatra Part Number: 9130450046 W-8945
- BOKYtage: 12 Volts
- Wattage: 1.2 KW
- Lanja entana: 15.8 kg
- Haben'ny vokatra: 6.5 x 4.5 x 4.5 santimetatra
- Fihodinana: Mifanohitra amin'ny famantaranandro (CCW)
- Karazan-tsofa: Slot Shaft
- Fametrahana Switch: Offset Holes
10. Warranty sy fanohanana
This Gladiator Pump Motor comes with a Garantie iray taona manomboka amin'ny datin'ny fividianana. Ity fiantohana ity dia manarona ny lesoka amin'ny fitaovana sy ny asa amin'ny fampiasana mahazatra.
For warranty claims, technical support, or further assistance, please contact your authorized Gladiator dealer or the point of purchase. Please have your model number and purchase date available when contacting support.
For additional information or to locate a service center, please visit the official Gladiator website (if available, link would be provided here).





