Notifier ISO-X Fault Isolator Module User Manual

Model: ISO-X

1. Fampidirana

The Notifier ISO-X Alarm Fault Isolator Module is designed to protect fire alarm system Signaling Line Circuits (SLC) from wire-to-wire short circuits. This module ensures that a short circuit on the SLC loop does not disable the entire loop, allowing other devices on the loop to continue functioning normally. It is an essential component for maintaining system integrity and reliability in fire detection and alarm systems.

The ISO-X module is compatible with various Notifier fire alarm control panels, including NFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, and System 5000.

2. Vokatra mihoatraview

Notifier ISO-X Fault Isolator Module in its packaging

Sary 2.1: anoloana view of the Notifier ISO-X Fault Isolator Module in its original packaging. The module is white with the Notifier by Honeywell logo prominently displayed. The packaging indicates "ISO-X" and "417480".

aoriana view of Notifier ISO-X Fault Isolator Module with wiring terminals

Sary 2.2: aoriana view of the Notifier ISO-X Fault Isolator Module, showing the mounting bracket and wiring terminals. Labels for SLC1 and SLC2 connections are visible, along with model number, country of origin (Mexico), and UL/FM listings. Installation instructions are referenced.

3. Fametrahana sy fametrahana

Installation of the ISO-X module should only be performed by qualified personnel in accordance with all local and national electrical codes, and the manufacturer's specific installation instructions (document 156-3624 referenced on the module itself).

  1. Fanapahan-jiro: Ataovy azo antoka fa tapaka avokoa ny herinaratra rehetra mankany amin'ny tontonana fanaraha-maso ny fanairana afo sy ireo faritra mifandraika amin'izany alohan'ny hanombohana ny fametrahana.
  2. Mametraka: Mount the ISO-X module in a suitable location, typically within an electrical enclosure or junction box, using the provided mounting holes. Ensure proper ventilation if required by local codes.
  3. Wiring: Connect the Signaling Line Circuit (SLC) wires to the designated terminals on the module. The module supports two SLC loops (SLC1 and SLC2) with positive (+) and negative (-) terminals for each. Refer to the wiring diagram provided with the module and the fire alarm control panel for correct polarity and connection points. The module is designed for 4-wire applications.
  4. Fanamarinana: After wiring, visually inspect all connections to ensure they are secure and correctly terminated.
  5. Famerenana herinaratra: Restore power to the fire alarm control panel and verify proper operation of the SLC loop and connected devices.

Note: The module is designed for indoor, dry applications only.

4. Fampandehanana

The Notifier ISO-X module operates passively within the SLC loop. In the event of a wire-to-wire short circuit on the SLC loop, the ISO-X module automatically isolates the affected segment of the loop. This isolation prevents the short circuit from disrupting communication with other devices on the healthy segments of the loop.

Once the short circuit condition is cleared, the ISO-X module automatically restores the isolated segment to normal operation, allowing full communication across the entire SLC loop without manual intervention.

5. Fikojakojana

The Notifier ISO-X module requires minimal maintenance. Regular system inspections and testing, as mandated by local fire codes and standards (e.g., NFPA 72), will ensure the continued proper functioning of the module and the overall fire alarm system.

6. Famahana olana

If a fault is indicated on the SLC loop, and the ISO-X module is suspected:

7. Famaritana

toetrasarobidy
Marikahampandre
Laharana modelyISO-X
Laharan'ny ampahanyISO-X
UPC636836973661
Loharanon-keryCorded Electric (SLC Loop)
lokoWhite
Lanja entana5.6 oz
Ny refin'ny vokatra6 x 6 x 2 santimetatra
Isan'ny singa1
FampiharanaIndoor, Dry Applications Only
mifanentanaNFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, System 5000

8. Warranty sy fanohanana

For specific warranty information regarding your Notifier ISO-X module, please refer to the documentation provided with your purchase or contact Notifier directly. Warranty terms typically cover defects in materials and workmanship under normal use.

For technical support, installation assistance, or to report issues, please contact Notifier customer service or your authorized Notifier distributor. When contacting support, please have your product model number (ISO-X) and any relevant system information ready.