Wilo Stratos PICO plus 25/1-3-130

Wilo Stratos PICO plus 25/1-6-130 High-Efficiency Heating Circulation Pump

User Manual

Model: Stratos PICO plus 25/1-3-130

1. Fampidirana

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wilo Stratos PICO plus high-efficiency heating circulation pump. Please read these instructions carefully before installation and initial operation. Keep this manual for future reference.

The Wilo Stratos PICO plus is designed as a circulation pump for hot water heating systems and various climate control applications. It features advanced technology for energy efficiency and ease of use.

2. Information momba ny fiarovana

Always observe the following safety instructions to prevent personal injury and damage to the equipment:

  • Installation and maintenance must only be carried out by qualified personnel in accordance with local regulations and standards.
  • Ataovy azo antoka fa tapaka ny herinaratra alohan'ny hanaovana fametrahana na fikojakojana.
  • The pump operates with electrical voltage. Avoid contact with live parts.
  • Do not operate the pump if it is damaged or if the electrical cable is faulty.
  • Arovy ny paompy amin'ny fanala.
  • Manaova fitaovana fiarovana manokana (PPE) sahaza mandritra ny fametrahana sy fikojakojana.

3. Fametrahana sy fametrahana

The Wilo Stratos PICO plus pump is designed for comfortable replacement and compact installation. It features a Wilo Connector for quick and tool-free electrical wiring.

3.1 Fametrahana ny paompy

Mount the pump in the heating system piping. Ensure the flow direction arrow on the pump housing matches the system's flow direction. The pump can be installed horizontally or vertically, but the motor shaft must always be horizontal.

Wilo Stratos PICO plus pump installed in a heating system

Figure 1: Wilo Stratos PICO plus pump installed in a typical heating system setup, showing its compact integration with existing pipes and gauges.

Two Wilo Stratos PICO plus pumps installed in a heating system

Figure 2: Two Wilo Stratos PICO plus pumps integrated into a larger heating system, demonstrating their versatility and ease of installation in various configurations.

3.2 Fifandraisana elektrika

The Wilo Connector simplifies electrical wiring. Ensure the power supply matches the pump's specifications (230 Volts). Connect the pump to a properly grounded electrical circuit.

Wilo Stratos PICO plus pump with Wilo Connector

Sary 3: akaiky view of the Wilo Stratos PICO plus pump, highlighting the Wilo Connector for electrical wiring and the insulation shell.

The pump comes with an insulation shell (Dämmschale) included in the scope of delivery to minimize heat loss.

4. Torolàlana miasa

The Wilo Stratos PICO plus features an intuitive LC display and precise setting options for optimal performance.

4.1 LC Display and Controls

The large LC display shows current power consumption, cumulative kWh, and volume flow. Functions and modes are displayed on the LC display and activated directly via the green button technology.

Wilo Stratos PICO plus LC display

Sary 4: antsipirihany view of the Wilo Stratos PICO plus LC display, showing various operational parameters and settings, including power consumption and volume flow.

Wilo Stratos PICO plus LC display close-up

Figure 5: Close-up of the Wilo Stratos PICO plus LC display, providing a clear view of the digital readouts for power (W), volume flow (m³/h), and cumulative energy consumption (kWh).

4.2 Operating Modes and Functions

  • Optimized Dynamic Adapt Function: Automatically adjusts pump performance to the system's requirements, ensuring energy efficiency.
  • Manual De-aeration Routine: Helps to remove air from the pump and system, preventing noise and ensuring proper operation.
  • Automatic Deblocking Function: Prevents the pump from seizing up after long periods of inactivity.

Refer to the on-screen menu for detailed navigation and setting adjustments using the green control button.

5. Fikojakojana

The Wilo Stratos PICO plus is designed for low maintenance. Regular checks can help ensure its longevity and efficient operation.

  • Fanaraha-maso maso: Periodically check the pump for any signs of leaks, corrosion, or damage.
  • Fanerena rafitra: Ensure the heating system pressure is within the recommended range.
  • Fanalana rivotra: Utilize the manual de-aeration routine if you notice gurgling noises or reduced heating performance.
  • Fanadiovana: Keep the exterior of the pump clean and free from dust and debris.

For any complex maintenance or repairs, contact a qualified service technician.

6. Famahana olana

If you encounter issues with your Wilo Stratos PICO plus pump, refer to the following common troubleshooting steps:

  • Pump Not Running:
    • Jereo ny famatsiana herinaratra sy ny fiatoana.
    • Ensure the electrical connection is secure.
    • Verify the pump is not in a standby or off mode on the display.
  • Noisy Operation / Gurgling:
    • Perform the manual de-aeration routine to remove trapped air.
    • Check system pressure.
  • Fampihenana ny hafanana:
    • Check pump settings on the LC display.
    • Ensure there is no air in the system.
    • Verify system pressure and flow.
  • Pump Seized:
    • The automatic deblocking function should prevent this. If it occurs, contact a qualified technician.

If the problem persists after attempting these steps, contact Wilo customer support or a certified service professional.

7. Famaritana

Below are the technical specifications for the Wilo Stratos PICO plus 25/1-3-130 pump:

endri-javatrasarobidy
mpanamboatraWILO SE
Haben'ny vokatra (L x W x H)15.6 x 18.6 x 11.6 cm
lanja2.04 kg
Laharana modelyStratos PICO plus 25/1-3-130
lokoMaitso
StyleANKEHITRINY
KEVITRAMetal, Carbon Steel
Loharanon-keryCable elektrika
BOKYtage230 Volts
Ny habetsahan'ny entana1
Ahitana bateriatsy misy
Ilaina ny bateriatsy misy
Fividianana kojakojaTsy misy fampahalalana azo alaina
Code International Articles04048482754451
Wilo Stratos PICO plus performance curve

Figure 6: Performance curve for Wilo Stratos PICO plus pumps, illustrating head (H/m) versus flow rate (Q/m³/h) for different models (15, 25, 30/1-6 and 15, 25, 30/1-4).

8. Warranty sy fanohanana

For warranty information, please refer to the documentation provided with your purchase or contact your local Wilo representative. For technical support, spare parts, or service, please visit the official Wilo webtranokala na mifandray amin'ny departemantan'ny serivisy mpanjifany.

Documents mifandraika - Stratos PICO plus 25/1-3-130

Preview Wilo-Stratos PICO Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining the Wilo-Stratos PICO high-efficiency circulation pump for heating systems. Includes safety, technical data, and operational procedures.
Preview Wilo-Stratos PICO Circulator Pump: Torolàlana fametrahana haingana
Ity antontan-taratasy ity dia manome torolàlana haingana ho an'ny paompy mivezivezy Wilo-Stratos PICO, natao ho an'ny rafitra fanafanana rano mafana. Tafiditra ao anatin'izany ny fampahalalana momba ny fametrahana sy ny fampandehanana tena ilaina, miaraka amin'ny fanondroana ny boky fampianarana feno.
Preview Wilo-Stratos PICO-Z High-Efficiency Circulator Pump: Installation and Operating Instructions
Detailed installation and operating manual for the Wilo-Stratos PICO-Z high-efficiency circulator pump (Article No. 4258257). This guide covers safety, technical specifications, installation, operation, commissioning, maintenance, and troubleshooting for drinking water recirculation systems in industrial and building services applications.
Preview Wilo-Stratos PARA-C/-CZ Installation and Operating Instructions
Comprehensive installation and operating instructions for the Wilo-Stratos PARA-C/-CZ high-efficiency circulation pump. Covers safety, transport, usage, product data, description, installation, commissioning, maintenance, and troubleshooting.
Preview Каталог насосов Wilo для бытового применения: отопление, водоснабжение, водоотведение
Обзор высокоэффективных циркуляционных насосов Wilo для систем отопления, водоснабжения и водоотведения. Информация для продавцов и монтажников.
Preview Wilo-Stratos PARA-C/-CZ High-Efficiency Circulation Pump Installation and Operating Manual
Comprehensive installation, operation, and maintenance guide for the Wilo-Stratos PARA-C/-CZ high-efficiency circulation pump, covering safety, technical data, installation, and troubleshooting.