Vita ny vokatraview
This manual provides essential information for the installation, operation, and maintenance of the True Relay, Compela RP7708-ZR 301 P270. This genuine OEM (Original Equipment Manufacturer) part is designed for commercial refrigeration systems, ensuring reliable performance and adherence to high industry standards.

Sary: The True Relay, Compela RP7708-ZR 301 P270, featuring a black plastic housing, exposed copper coil windings, and a metal terminal block. This component is crucial for electrical control in refrigeration units.
Information momba ny fiarovana
Always disconnect power before installing or servicing the relay. Installation should be performed by qualified personnel only. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- Hamarino tsara ny tany.
- Hamarino voltagMifanaraka amin'ny fampiharana ny naoty e sy ny naoty ankehitriny.
- Do not operate if the relay appears damaged.
Fametrahana sy fametrahana
The True Relay, Compela RP7708-ZR 301 P270 is designed for easy integration into compatible refrigeration systems. Refer to your equipment's specific wiring diagrams for precise connection points.
- Fanapahan-jiro: Before beginning any installation, ensure that the main power supply to the refrigeration unit is completely disconnected and locked out.
- Locate Existing Relay: Identify the current relay to be replaced. Note its orientation and wiring connections.
- Disconnect Wiring: Carefully disconnect all wires from the old relay, labeling them if necessary to ensure correct re-connection.
- Esory ny relay taloha: Unmount the old relay from its position. This model typically uses a DIN Rail Mount.
- Mametraka Relay Vaovao: Mount the new True Relay (Model 963194) securely in the designated location.
- Connect Wiring: Reconnect the wires to the new relay according to the system's wiring diagram. Ensure all connections are secure and tight. This relay features a Zircon connector type and Normally Open contact type.
- Hamarino ny fametrahana: Double-check all connections and mounting.
- Ampodio hery: Once installation is complete and verified, restore power to the refrigeration unit.
Torolàlana miasa
The True Relay operates automatically as part of the refrigeration system's control circuit. It is designed to switch electrical loads based on signals from the system's thermostat or other control devices.
- Upon power-up, the relay will be in its default (normally open) state.
- When the control circuit signals the relay, it will close its contacts, allowing power to flow to the connected component (e.g., compressor, fan motor).
- When the signal is removed, the relay contacts will open, interrupting the power flow.
- No direct user interaction is required for the relay's operation once installed correctly.
fikarakarana
The True Relay is a robust component designed for long-term reliability with minimal maintenance. However, periodic inspection can help ensure optimal performance.
- Fanaraha-maso maso: Annually inspect the relay for any signs of physical damage, discoloration, or loose connections.
- Fanamarinana fifandraisana: Ataovy azo antoka fa mafy tsara ary tsy misy harafesina ny fifandraisana elektrika rehetra.
- Fanadiovana: If dust or debris accumulates, gently clean the exterior of the relay with a dry, soft cloth. Do not use liquid cleaners.
- Fepetra ara-tontolo iainana: Ensure the operating environment remains within the specified temperature and humidity ranges for the refrigeration unit.
Fanamboarana
If the refrigeration unit is not functioning as expected, the relay may be a contributing factor. Always consult a qualified technician for complex issues.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Relay tsy mihetsika | No control signal; Faulty wiring; Relay failure | Check control circuit; Inspect wiring for breaks/shorts; Test relay continuity (if qualified) |
| Relay contacts stuck closed/open | Internal mechanical failure; Contact welding due to overload | Replace relay; Verify load current does not exceed relay rating |
| Burning smell or discoloration | Overheating due to overload or loose connection | Immediately disconnect power; Replace relay; Check load and connections |
| Hetsika miato | Loose connections; Vibrations; Degrading internal components | Tighten connections; Secure mounting; Consider relay replacement |
Fanamarihana: Always ensure power is disconnected before performing any inspection or troubleshooting steps. If you are unsure, contact a certified technician.
fepetra arahana
| Laharana modely | 963194 |
| Ny refin'ny vokatra | 4 x 6 x 9 santimetatra; 1.27 ,XNUMXozy |
| Marika | Marina |
| Karazana mpampitohy | Zirkon |
| Fitaovana mifandray | Silver |
| Karazana fifandraisana | Misokatra mahazatra |
| Karazana fametrahana | DIN Rail Mount |
| Firenena nihaviana | BREZILA |
Inona no ao anaty boaty
- Replacement Part (True Relay, Compela RP7708-ZR 301 P270)
Warranty sy fanohanana
As a genuine OEM part, this True Relay is covered by the manufacturer's standard warranty for replacement parts. For specific warranty terms and conditions, please refer to the documentation provided with your original True refrigeration equipment or contact True customer support.
For technical support or inquiries regarding this product, please contact True Refrigeration directly. Contact information can typically be found on the True Refrigeration official website or within your equipment's main user manual.
Fanamarihana: Unauthorized modifications or improper installation will void the product warranty.