1. Vokatra mihoatraview
The Myers HJ50D is a convertible deep water well jet pump designed for reliable water supply from deep well applications. This 1/2 HP pump operates on either 115V or 230V, providing versatility for various electrical setups. It is engineered for efficient performance in residential and light commercial water systems.
- Deep Water Well Jet Pump functionality.
- 1/2 Horsepower motor for effective water transfer.
- Dual voltage operation: 115V or 230V.

An image showing the Myers HJ50D Convertible Deep Water Well Jet Pump, a green-colored unit with a motor on one end and the pump housing with inlet/outlet ports on the other. This pump is designed for deep well applications.
2. Information momba ny fiarovana
Read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions can result in serious injury, death, or property damage.
- Loza elektrônika: Always disconnect power before servicing the pump. Ensure proper grounding and wiring according to local electrical codes.
- Loza ateraky ny tsindry: Water systems operate under pressure. Relieve system pressure before servicing.
- Ampahany mihetsika: Arovy amin'ny zavatra mihetsika ny tanana sy ny akanjo mandritra ny fampiasana.
- Toerana mafana: The pump motor can become hot during operation. Allow it to cool before handling.
- Mpiasa mahafeno fepetra: Installation and electrical connections should only be performed by qualified personnel.
3. Fametrahana sy fametrahana
3.1 Fanamarinana mialoha ny fametrahana
- Verify the power supply matches the pump's voltagfepetra takiana (115V na 230V).
- Ensure the well casing is clean and free of debris.
- Confirm adequate space for pump installation and future maintenance.
3.2 Fametrahana ny paompy
Mount the pump on a firm, level foundation to minimize vibration. Use appropriate bolts and washers to secure the pump base. Ensure the pump is as close to the well as practical to reduce suction lift.
3.3 Fifandraisana amin'ny fantson-drano
- Connect the suction line from the well to the pump's suction port. Ensure all connections are airtight to prevent air leaks.
- Connect the discharge line from the pump to the pressure tank and distribution system.
- Install a check valve in the suction line if not already present in the jet assembly.
- Install a pressure gauge and pressure switch on the discharge side.
3.4 Wiring elektrika
Wire the pump according to the wiring diagram provided on the motor nameplate and local electrical codes. Ensure the correct voltage selection (115V or 230V) is made before connecting power. The pump must be properly grounded.
3.5 Fanomanana ny paompy
Before initial startup, the pump casing and suction line must be completely filled with water. Remove the priming plug, slowly fill the pump with water until it overflows, then replace the plug securely. This process removes air from the pump, allowing it to create suction.
4. Torolàlana miasa
4.1 Fanombohana voalohany
- Ensure the pump is properly primed as described in Section 3.5.
- Open a faucet in the system to allow air to escape.
- Restore power to the pump. The pump should start and begin to draw water.
- Once a steady stream of water flows from the faucet, close the faucet. The pump will build pressure and shut off when the pressure switch setting is reached.
4.2 Fampandehanana mahazatra
The pump will automatically cycle on and off based on the pressure switch settings, maintaining system pressure as water is used. Monitor the pressure gauge periodically to ensure proper operation.
4.3 Fanakatonana ny paompy
To temporarily or permanently shut down the pump, disconnect the electrical power supply at the circuit breaker or fuse box. If shutting down for an extended period or for winterization, refer to the maintenance section.
5. Fikojakojana
Regular maintenance ensures the longevity and efficient operation of your Myers HJ50D pump. Always disconnect power before performing any maintenance.
5.1 Fanaraha-maso tsy tapaka
- Check for leaks around plumbing connections.
- Inspect electrical wiring for signs of wear or damage.
- Henoy tsara raha misy feo tsy mahazatra mandritra ny fampiasana, izay mety ho famantarana fa misy olana.
- Verify the pressure switch is operating correctly and maintaining desired pressure.
5.2 Fametrahana ny ririnina
In areas subject to freezing temperatures, the pump and associated piping must be drained to prevent damage. Disconnect power, open drain plugs on the pump and any exposed piping, and allow all water to drain completely. Store the pump in a warm, dry place if possible, or ensure it is thoroughly drained and protected from freezing.
6. Famahana olana
This section provides solutions to common operational issues. For problems not listed or if solutions do not resolve the issue, contact a qualified service technician.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy manomboka ny paompy. | No power; tripped circuit breaker; faulty pressure switch; motor issue. | Check power supply; reset breaker; inspect/replace pressure switch; consult technician. |
| Pump runs but delivers no water. | Pump not primed; air leak in suction line; low water level in well; clogged foot valve. | Re-prime pump; check suction line connections; verify well water level; inspect/clean foot valve. |
| Fanerena rano ambany. | Partially clogged lines; worn pump components; pressure switch setting too low; air in system. | Inspect/clean lines; service pump; adjust pressure switch; bleed air from system. |
| Ny paompy dia mandeha tsy tapaka. | Leak in system; faulty pressure switch; pump unable to build pressure. | Check for leaks; inspect/replace pressure switch; troubleshoot for no water/low pressure issues. |
7. Famaritana
| toetra | antsipirihany |
|---|---|
| Marika | Myers |
| Laharana modely | HJ50D |
| Laharan'ny ampahany | HR50D |
| Horsepower (HP) | 1 / 2 HP |
| BOKYtage | 115V/230V |
| Loharanon-kery | AC/DC |
| Lanja entana | 44 kg |
| Style | Convertible Deep Water Well Jet Pump |
| UPC | 713356111732 |
8. Warranty sy fanohanana
For detailed warranty information, please refer to the warranty card included with your product or visit the official Myers website. Tehirizo ny tapakila fividiananao ho porofon'ny fividianana ho an'ny fitakiana fiantohana.