HILTI 3436798

Hilti CP 606 Firestop Sealant Instruction Manual

Model: CP 606 (3436798)

1. Vokatra mihoatraview

The Hilti CP 606 Firestop Sealant is a high-performance, intumescent acrylic sealant designed for firestopping applications. It expands when exposed to heat, forming a fire-resistant barrier that helps prevent the spread of fire and smoke through penetrations in fire-rated constructions. This product is suitable for various joint and penetration sealing applications in walls and floors.

Hilti CP 606 Firestop Sealant 10.5oz tube

An image showing a single 10.5oz tube of Hilti CP 606 red firestop sealant, clearly displaying the Hilti logo and product identification.

2. Information momba ny fiarovana

Always prioritize safety when working with sealants. Read and understand the Safety Data Sheet (SDS) before use. Observe all local safety regulations.

  • Fitaovana fiarovana manokana (PPE): Wear appropriate PPE, including safety glasses, gloves, and protective clothing, to prevent skin and eye contact.
  • rivotra: Use in well-ventilated areas. If adequate ventilation is not available, use respiratory protection.
  • Fifandraisana amin'ny hoditra: Raha sendra misy hoditra dia sasao tsara amin'ny savony sy rano.
  • Fifandraisana amin'ny maso: In case of eye contact, flush immediately with plenty of water for several minutes and seek medical attention.
  • Fandevonan-kanina: Aza atelina. Raha voatelina dia mitadiava fitsaboana avy hatrany.
  • Tazony tsy ho tratra: Arovy amin'ny ankizy sy ny biby fiompy.

3. Fametrahana sy Fiomanana

  1. Fiomanana ambonin'ny tany: Ensure all surfaces to be sealed are clean, dry, and free from dust, oil, grease, loose particles, and other contaminants. Substrates should be sound and stable.
  2. Joint Dimensions: Verify that joint dimensions are within the product's specified limits for optimal performance.
  3. Fitaovana fanohanana: For deeper joints, use a suitable backing material (e.g., backer rod) to control sealant depth and ensure proper sealant geometry.
  4. Fitaovana ilaina:
    • Standard caulking gun
    • Utility knife or sealant cutter
    • Trowel or tooling stick for finishing
    • Cleaning supplies (rags, appropriate solvent if needed)
  5. Temperature: Apply the sealant within the recommended temperature range, typically between 5°C and 40°C (41°F and 104°F).

4. Torolàlana fampiharana

  1. Prepare Cartridge: Cut the tip of the sealant tube at a 45-degree angle to the desired bead size. Puncture the inner seal of the cartridge.
  2. Load Caulking Gun: Insert the prepared cartridge into a standard caulking gun.
  3. Ampiharo sealant: Apply the sealant evenly and continuously into the joint or penetration, ensuring full contact with the substrate. Maintain consistent pressure on the trigger to achieve a smooth, uniform bead.
  4. Fitaovana: Within 5-10 minutes of application (before skinning occurs), tool the sealant to ensure good adhesion and a smooth finish. Remove any excess sealant immediately.
  5. Fanasitranana: The sealant will skin over in approximately 15-30 minutes, depending on temperature and humidity. Full cure time can range from several days to weeks, depending on bead thickness and environmental conditions. Protect the freshly applied sealant from water and heavy traffic until fully cured.

5. Fikojakojana

Once cured, Hilti CP 606 Firestop Sealant requires minimal maintenance. Periodically inspect sealed joints and penetrations for any signs of damage, cracking, or degradation. If damage is observed, clean the area and reapply sealant as necessary to maintain the firestop integrity.

6. Famahana olana

  • Firaikitra ratsy:

    Ensure surfaces are clean, dry, and free of contaminants. Proper surface preparation is critical for good adhesion.

  • Slow Curing:

    Low temperatures and high humidity can extend curing times. Ensure adequate ventilation and maintain recommended application temperatures.

  • Cracking or Shrinkage:

    Excessive joint movement or improper joint design can lead to cracking. Ensure correct joint dimensions and use of backing material where appropriate.

7. Famaritana

endri-javatraantsipirihany
MarikaHILTI
Laharana modely3436798 (CP 606)
Endri-javatraLiquid (Sealant)
lokoMENA
Haben'ny kaontenera10.5 oz Tube
Ny haavon'ny fanoherana ny ranoTsy tantera-drano
mpanamboatraHilti
Daty azo alaina voalohany9 Oktobra 2017

8. Fitehirizana sy fanariana

  • fitahirizana: Store the sealant in its original, unopened packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Recommended storage temperature is typically between 5°C and 25°C (41°F and 77°F).
  • fanariana: Dispose of unused product and empty containers in accordance with local, state, and federal regulations. Do not dispose of in drains or waterways. Consult local waste management authorities for proper disposal methods.

9. Warranty sy fanohanana

For specific warranty information regarding the Hilti CP 606 Firestop Sealant, please refer to the official Hilti website or contact Hilti customer service directly. Hilti provides comprehensive technical support and product documentation to assist with proper application and performance.

Hilti Official Webtranokala: www.hilti.com

Documents mifandraika - 3436798

Preview Hilti Firestop Acrylic Sealant CFS-S ACR / CP 606 - Torolàlana momba ny fampiharana
Torolàlana feno amin'ny fampiharana Hilti Firestop Acrylic Sealant CFS-S ACR / CP 606, amin'ny antsipiriany ny fomba famehezana iraisana sy fidirana miaraka amin'ny toro-làlana momba ny fanasitranana sy fiarovana.
Preview Hilti CP 670 Firestop Coating System: Folder fandefasana sy angona teknika
Lahatahiry fandefasana feno ho an'ny Hilti CP 670 Firestop Coating System, ao anatin'izany ny fampahalalana momba ny vokatra, ny fomba fanambarana, ny tatitra andrana avy amin'ny Oniversiten'i Macau, ny votoatin'ny VOC, ny fankatoavana, ny firenena niaviany, ny fampahalalana LEED, ary ny fanamafisana tsy CFC/ozone. Ny antsipiriany momba ny teknika, ny fomba fampiharana ary ny fanondroana asa.
Preview Hilti Technical Manuals: Fire Protection Solutions for Systems, Joints, and Facades
Comprehensive technical manuals from Hilti detailing fire protection solutions for systems, joints, and facades, including sealants, bandages, collars, blocks, and cavity barriers.
Preview Hilti Firestop Selector on HCP 2.0 User Guide
A comprehensive user guide for navigating and utilizing the Hilti Firestop Selector tool on the Hilti Construction Platform (HCP) 2.0, covering login, settings, search, submittal generation, and mobile app features.
Preview Hilti CP 617 Firestop Putty Pad Installation Guide
Detailed installation instructions for the Hilti CP 617 Firestop Putty Pad, covering preparation, application steps, and proper sizing for electrical boxes to ensure fire safety compliance.
Preview Hilti Firestop Bandage CFS-B Boky Torolàlana ara-teknika sy fampiharana
Torolàlana ara-teknika feno ho an'ny Hilti Firestop Bandage CFS-B, manazava ny fampiharana azy, advantages, fepetra ara-teknika, torolalana amin'ny fametrahana, torolàlana momba ny fanjifana, ary fampiasana ankatoavina amin'ny fandoroana ireo karazana fantsona isan-karazany amin'ny fanorenana rindrina sy gorodona samihafa.