Zoeller 807-0001

Zoeller Shark Model 807-0001 Residential Grinder Pump User Manual

Model: 807-0001 | Brand: Zoeller

Sava lalana

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Zoeller Shark Model 807-0001 Residential Grinder Pump. Please read this manual thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

The Zoeller Shark Model 807-0001 is a 1 HP, 115V residential grinder pump designed for handling wastewater and effluent in residential applications. It features a robust grinding mechanism to reduce solids into a fine slurry, allowing for discharge through small diameter piping.

Information momba ny fiarovana

WARNING: Risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

Fametrahana sy fametrahana

Proper installation is crucial for the longevity and performance of your grinder pump. Consult a qualified professional for installation if you are unsure.

Famoahana sy fisafoana

Carefully remove the pump from its packaging. Inspect for any visible damage that may have occurred during shipping. Report any damage to your supplier immediately.

Zoeller Shark Model 807-0001 Residential Grinder Pump

Figure 1: Zoeller Shark Model 807-0001 Residential Grinder Pump. This image shows the complete pump unit with its float switch mechanism.

Location and Sump Requirements

Piping Connections

Fifandraisana elektrika

Torolàlana miasa

Once installed and connected, the Zoeller Shark Model 807-0001 operates automatically via its float switch.

Fanombohana voalohany

  1. Ensure all piping and electrical connections are secure.
  2. Slowly fill the sump with water to activate the float switch.
  3. Observe the pump for proper operation: it should turn on, pump down the water, and then turn off.
  4. Check for any leaks in the discharge piping.

Normal Operation

The pump will activate when the water level rises to the "on" level set by the float switch and will continue to run until the water level drops to the "off" level. The grinding mechanism processes solids before pumping.

Zoeller Shark Grinder Pump Impeller and Grinding Plate

Sary 2: akaiky view of the Zoeller Shark Grinder Pump's impeller and grinding plate. This mechanism is responsible for reducing solids in wastewater.

fikarakarana

Regular maintenance helps ensure reliable operation and extends the life of your pump.

Routine Checks (Monthly)

Annual Inspection (Professional Recommended)

TANDREMO: Tapaho foana ny herinaratra alohan'ny hanaovana fikojakojana na fitsirihana.

Fanamboarana

Ity fizarana ity dia manome vahaolana amin'ireo olana mahazatra. Raha misy olana tsy voatanisa dia mifandraisa amin'ny serivisy ho an'ny mpanjifa.

OLANAAntony mety hitrangavahaolana
Tsy mandeha ny paompyNo power; tripped breaker; faulty float switch; motor overload.Check power supply and breaker. Inspect float switch for obstruction. Reset thermal overload if present.
Ny paompy dia mandeha tsy tapakaStuck float switch; check valve failure; discharge line blockage.Clear float switch. Inspect/replace check valve. Clear discharge line.
Mandeha ny paompy fa tsy misy rano mivoakaAir lock; clogged impeller/grinder; discharge line blockage.Vent air from pump. Clear impeller/grinder. Clear discharge line.
Fitabatabana na vibration be loatraDebris in pump; worn bearings; improper installation.Disconnect power and inspect for debris. Contact service professional for worn parts.

fepetra arahana

endri-javatraantsipirihany
Laharana modely807-0001
MarikaZoeller
Horsepower1 HP
BOKYtage115 Volts
Loharanon-keryAC/DC
Taham-pidirana ambony indrindra45 galona isa-minitra
Lanja entana65 kilao
Ny refin'ny vokatra17.25" L x 8.91" W x 17.25" H
KEVITRAInôksa

Warranty Information

Zoeller Company products are warranted against defects in material and workmanship for a period specified by the manufacturer from the date of purchase. Specific warranty terms and conditions may vary. Please refer to the official Zoeller Company warranty statement provided with your product or visit the manufacturer's webtranokala hahazoana fampahalalana amin'ny antsipiriany.

Note: Improper installation, unauthorized repairs, or misuse of the product may void the warranty.

Fanohanana ny mpanjifa

For technical assistance, replacement parts, or warranty claims, please contact Zoeller Customer Support.

Documents mifandraika - 807-0001

Preview Zoeller Shark 803, 805, 807 Fractional HP Grinder Pumps - Andian-trano
Diniho ny Zoeller Shark Series paompy fikosoham-tsoavaly fractional (modely 803, 805, 807) natao ho an'ny fampiasana rano maloto ao an-trano. Ny endri-javatra dia misy ny fananganana vy, Tri Slice® Cutter Technology, ary safidy mandeha ho azy/tsy mandeha ho azy. View angona fampisehoana sy fampitahana modely.
Preview Zoeller Shark Series Fractional HP Grinder Pumps Models 803/805/807 Technical Data Sheet
Detailed technical specifications, performance curves, and model comparison for Zoeller's Shark Series Fractional HP Grinder Pumps (Models 803, 805, 807). These cast iron pumps are designed for residential sewage applications handling 'flushable' materials.
Preview Zoeller 803/805/807 Grinder Pumps Installation and Service Instructions
Comprehensive installation, service, and warranty information for Zoeller 803, 805, and 807 Grinder Pumps. Includes pre-installation checklists, safety warnings, installation recommendations, wiring diagrams, repair procedures, performance data, and troubleshooting.
Preview Zoeller 803/805/807 Grinder Pumps: Installation and Service Instructions
Comprehensive installation, service, and warranty guide for Zoeller 803, 805, and 807 series submersible grinder pumps. Includes pre-installation checklists, safety warnings, wiring diagrams, repair procedures, and performance data.
Preview Zoeller 900 Series Preassembled Sump Pump Systems - Easy Installation
Discover the Zoeller 900 Series preassembled sump pump systems, designed for fast and easy installation. Features include automatic float switch, durable cast iron pump, and various basin options for residential and commercial use. Learn about model specifications and performance.
Preview Zoeller Model 840 & 841 Shark Dual Seal Grinder Pumps Technical Data Sheet
Famaritana ara-teknika feno, angon-drakitra fampisehoana, fampahalalana elektrika, ary singa rafitra ho an'ny Zoeller Model 840 sy 841 Shark Dual Seal Grinder Pumps, amin'ny antsipiriany ny endri-javatra, ny refy ary ny fahaizany miasa.