FireAngel HT-630R

FireAngel HT-630 Heat Alarm

Boky Torolàlana ho an'ny mpampiasa

Model: HT-630R | Brand: FireAngel

1. Fampidirana

The FireAngel HT-630 Heat Alarm is designed to provide early warning of fires by detecting rapid increases in temperature. Unlike smoke alarms, this heat alarm utilizes Thermistek technology to react to heat rather than smoke, making it ideal for installation in environments where smoke alarms might frequently trigger false alarms, such as kitchens, garages, and lofts.

This alarm features a sealed 10-year battery, ensuring continuous protection without the need for battery replacement throughout its operational lifespan. It is equipped with a test/silence button for easy functional checks and temporary silencing.

Lafin-javatra fototra:

  • Thermistek heat sensing technology for rapid temperature increase detection.
  • 10-year sealed battery life, eliminating battery changes.
  • Integrated power indicator and test/silence button.
  • Suitable for kitchens, garages, and lofts where smoke alarms are not recommended.
  • Audible alarm with 85 decibels sound level.
FireAngel HT-630 Heat Alarm front view

Sary 1: anoloana view of the FireAngel HT-630 Heat Alarm, showing the central test button and warning text.

2. Information momba ny fiarovana

Azafady vakio tsara ny toromarika rehetra alohan'ny hametrahana sy hampiasana azy. Tazomy ity boky torolalana ity ho an'ny fampiasana amin'ny ho avy.

  • This heat alarm is designed for domestic use only.
  • Do not paint the alarm. Paint can block the sensor and prevent proper operation.
  • Aza apetraka amin'ny toerana misy mari-pana na hamandoana tafahoatra.
  • Regularly test the alarm as described in the 'Operation' section.
  • The battery is sealed and not replaceable. Do not attempt to open the unit.
  • Upon activation, the alarm produces a loud sound. Avoid prolonged exposure to the alarm sound at close range.

3. Fametrahana sy fametrahana

Fametrahana soso-kevitra:

Heat alarms are specifically recommended for areas where smoke alarms are unsuitable due to potential false alarms. These areas include:

  • lakozia: To detect fires from cooking without reacting to cooking fumes.
  • Garage: To detect fires from vehicles or stored flammable materials without reacting to vehicle exhaust.
  • Lofts/Attics: Where dust or temperature fluctuations might affect smoke alarms.

Install the alarm on the ceiling, centrally in the room if possible, and at least 30cm (12 inches) away from walls or light fittings. Avoid placing near air vents, fans, or areas with high airflow that could interfere with heat detection.

Diagram of recommended alarm placement in a home

Sary 2: Diagram illustrating recommended placement of various alarms within a home, specifically showing heat alarms in the kitchen, garage, and loft.

Dingana fametrahana:

  1. Prepare the Mounting Plate: Separate the mounting plate from the alarm unit by twisting the alarm counter-clockwise.
  2. Marika sy fandavahana: Hold the mounting plate against the ceiling at your desired installation point. Mark the positions for the screw holes. Drill holes and insert wall plugs if necessary.
  3. Attach Mounting Plate: Secure the mounting plate to the ceiling using the provided screws. Ensure it is firmly attached.
  4. Attach Alarm Unit: Align the alarm unit with the mounting plate and twist it clockwise until it clicks securely into place. This action will activate the sealed battery.
  5. Andramo ny fanairana: Press and hold the test button for a few seconds until the alarm sounds. This confirms proper installation and functionality.
Three-step installation diagram for heat alarm

Sary 3: Diagram showing the three-step installation process for the heat alarm: preparing the mounting plate, attaching it to the ceiling, and twisting the alarm onto the plate.

4. Fampandehanana

Fitsapana ny fanairana:

It is crucial to test your heat alarm regularly to ensure it is functioning correctly. Test the alarm weekly or at least monthly.

  • Press and hold the large 'TEST / x' button located on the front of the alarm.
  • The alarm will emit a loud, continuous sound. Release the button when the sound stops.
  • If the alarm does not sound, refer to the 'Troubleshooting' section.

Fanairana famantarana:

  • Loud, Continuous Alarm: Indicates a rapid rise in temperature has been detected, signaling a potential fire. Evacuate the premises immediately.
  • Short Chirp (every 45 seconds): Indicates a low battery warning. Since the battery is sealed, the entire unit must be replaced.
  • Short Chirp (every 30 seconds): Indicates a fault with the alarm. The unit should be replaced.
Infographic explaining Thermistek technology

Sary 4: Infographic explaining Thermistek technology, comparing its rapid heat detection to conventional heat alarms with diagrams of convection currents and radiant energy.

5. Fikojakojana

The FireAngel HT-630 Heat Alarm requires minimal maintenance due to its sealed battery and design.

  • Fitsapana tsy tapaka: As mentioned in the 'Operation' section, test the alarm weekly or monthly.
  • Fanadiovana: Gently vacuum the alarm's exterior with a soft brush attachment once a month to remove dust and debris. Do not use cleaning solvents or spray chemicals directly on the alarm.
  • Batterie: The 10-year sealed battery is designed to last the lifetime of the alarm. If a low battery chirp occurs, the entire unit must be replaced.
  • Faran'ny fiainana: After 10 years from activation, the alarm will indicate its end-of-life. Replace the unit promptly.

6. Famahana olana

  • Alarm does not sound during test:
    Ensure the alarm is correctly twisted onto its mounting plate, activating the battery. If it still doesn't sound, the unit may be faulty and requires replacement.
  • Alarm chirps every 45 seconds:
    This indicates a low battery. The sealed battery cannot be replaced. The entire alarm unit must be replaced.
  • Alarm chirps every 30 seconds:
    This indicates a fault with the alarm unit. The alarm should be replaced immediately.
  • Fanairana diso:
    While less common with heat alarms, ensure the alarm is not installed directly above heat sources (e.g., stove burners, ovens) or in areas with extreme temperature fluctuations. If false alarms persist, review placement and consider if the environment is suitable for a heat alarm.

7. Famaritana

endri-javatraantsipirihany
Laharana modelyHT-630R
Teknolojia DetectionThermistek Heat Sensing
Loharanon-kerySealed 10-Year Lithium Battery
Ambaratonga feo fanairana85 Decibels at 3 meters
Ny refin'ny vokatra5.31 x 5.31 x 2.36 santimetatra
Lanja entana6.3 ounces (180 grama)
KEVITRAplastika
CertificationCE marked, Kitemarked (BS 5446-2:2003 KM 677057)
Fampiasana tontolo iainanaIndoor (Kitchens, Garages, Lofts)
CE and Kitemark certification logos

Sary 5: Image displaying the CE mark and Kitemark certification logos, indicating compliance with European safety standards (BS 5446-2:2003 KM 677057).

8. Warranty sy fanohanana

Manufacturer's Guarantee:

The FireAngel HT-630 Heat Alarm comes with a 10-year manufacturer's guarantee, covering defects in materials and workmanship under normal use and service. This guarantee period begins from the date of purchase.

Azafady, tehirizo ny porofon'ny fividiananao ho an'ny fitakiana fiantohana.

Fanohanana ny mpanjifa:

For technical assistance, warranty claims, or further information regarding your FireAngel HT-630 Heat Alarm, please contact FireAngel customer support through their official webtranonkala na ny antsipirian'ny fifandraisana nomena miaraka amin'ny fonosan'ny vokatrao.

Webtranokala: www.fireangel.co.uk

Documents mifandraika - HT-630R

Preview Torolàlana fametrahana ny FireAngel ZW-MODULE
Torolàlana feno momba ny fametrahana sy ny fanamboarana ny môdioly fifandraisana tsy misy tariby FireAngel ZW-MODULE ho an'ny fanairana setroka sy hafanana mifanaraka amin'ny Z-Wave. Tafiditra ao anatin'izany ny fametrahana, ny fanoloana bateria, ny famahana olana, ary ny fampahalalana momba ny garantie.
Preview FireAngel SM-SN-1 and HM-SN-1 Mains Powered Smoke and Heat Alarm Installation and User Guide
Comprehensive guide for installing and using FireAngel SM-SN-1 (Mains Powered Smoke Alarm) and HM-SN-1 (Mains Powered Heat Alarm). Covers system grades, positioning, hardwire and wireless interlinking, alarm testing, smart silence features, troubleshooting, maintenance, and warranty information.
Preview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Preview FireAngel: Fampahalalana manan-danja ho an'ny mponina ao an-trano momba ny rafitra famantarana afo sy fanairana
Torolalana ho an'ny tompon-trano momba ny fampiasana, fikojakojana ary fahatakarana ny rafitra famantarana sy fanairana afo FireAngel, anisan'izany ny fihetsika atao mandritra ny fanairana, ny fisorohana ny fanairana diso, ary ny fanamarinana mahazatra.
Preview FireAngel W2-MODULE P-LINE Installation Guide
Comprehensive installation guide for the FireAngel W2-MODULE P-LINE wireless module, detailing setup, interlinking Wi-Safe 2 alarms, troubleshooting, and warranty information for enhanced fire safety systems.
Preview FireAngel Smoke & Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
Comprehensive user manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Covers installation, maintenance, troubleshooting, warranty, and disposal.