1. Fampidirana
This manual provides essential information for the safe and efficient operation of your Mastervolt ChargeMaster Plus 12/35-3 Battery Charger. Please read this manual thoroughly before installation and use to ensure proper functionality and to prevent damage to the unit or connected systems.
The Mastervolt ChargeMaster Plus 12/35-3 is an advanced automatic battery charger designed for marine and automotive applications, providing optimal charging for various battery types.
2. Information momba ny fiarovana
FAMPITANDREMANA: Ny tsy fanarahana ireto toromarika fiarovana ireto dia mety hiteraka fahatairana herinaratra, afo, na ratra mafy.
- Always disconnect power before installing or servicing the charger.
- Hamarino tsara ny rivotra manodidina ny charger mba hisorohana ny hafanana be loatra.
- Do not expose the charger to rain, spray, or excessive moisture.
- This device is designed for indoor use in a protected environment.
- Ny mpiasa mahay ihany no tokony hanao fametrahana sy fikojakojana.
- Aza miasa ny charger raha toa ka simba amin'ny fomba rehetra.
- Keep flammable materials away from the charger.
For detailed safety guidelines, refer to local electrical codes and marine standards.
3. Ny votoatin'ny fonosana
Hamarino fa misy ny entana rehetra ao anaty fonosana:
- Mastervolt ChargeMaster Plus 12/35-3 Battery Charger Unit
- Fitaovana fametrahana (visy, milina fanasana)
- User Manual (ity antontan-taratasy ity)
- Karatra fiantohana
4. Fametrahana sy fametrahana
4.1 Fametrahana ny Charger
The ChargeMaster Plus 12/35-3 should be mounted in a dry, well-ventilated area, away from direct sunlight and heat sources. Ensure sufficient clearance around the unit for airflow.
- Select a suitable mounting location that can support the weight of the charger.
- Use the provided mounting template (if applicable) or measure the mounting holes on the back of the unit.
- Secure the charger firmly to a solid surface using appropriate screws and fasteners.
Sary 1: aoriana view of the Mastervolt ChargeMaster Plus 12/35-3, illustrating the integrated mounting brackets for secure installation.
4.2 Fifandraisana elektrika
All electrical connections must comply with local regulations and standards. Consult a qualified electrician if unsure.
- Connect the AC input cable to a grounded power source.
- Connect the DC output cables to your battery bank(s). Ensure correct polarity (positive to positive, negative to negative). The ChargeMaster Plus 12/35-3 supports multiple battery banks.
- Verify all connections are secure and free from corrosion.
Sary 2: Eo anoloana view of the Mastervolt ChargeMaster Plus 12/35-3, showing the control panel and connection points.
Figure 3: Angled top view of the Mastervolt ChargeMaster Plus 12/35-3, highlighting the ventilation grilles and overall compact design.
5. Torolàlana miasa
5.1 Mamelona/Mamono
Once all connections are made, connect the charger to the AC power source. The charger will automatically initiate its startup sequence.
- To power on: Ensure AC power is supplied. The power indicator light will illuminate.
- To power off: Disconnect the AC power source.
5.2 Fomba fiampangana
The ChargeMaster Plus 12/35-3 features an intelligent 3-stage+ charging process to optimize battery life and performance:
- Bulk Stage: Delivers maximum current to rapidly charge the battery to approximately 80%.
- Sitrohana Stage: Charges the battery to 100% at a constant voltage, gradually reducing current.
- Mitsingevana Stage: Maintains the battery at full charge with a low, constant voltage, preventing overcharging.
- Maintenance Stage: Periodically checks battery voltage and initiates a new charging cycle if needed.
The charger automatically detects the battery type and condition to apply the most suitable charging profile. Refer to the display indicators for charging status.
6. Fikojakojana
Regular maintenance ensures the longevity and optimal performance of your Mastervolt ChargeMaster Plus 12/35-3.
- Fanadiovana: Periodically wipe the exterior of the charger with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- rivotra: Ensure that the ventilation openings are clear of dust and debris. Blocked vents can lead to overheating.
- Fifandraisana: Annually inspect all electrical connections for tightness and signs of corrosion. Tighten any loose connections and clean corroded terminals.
- Tontolo iainana: Confirm the charger remains in a dry, protected environment.
CAUTION: Do not open the charger casing. Tsy misy piesy azo amboarina ao anatiny.
7. Famahana olana
This section addresses common issues you might encounter with your charger. For problems not listed here, contact Mastervolt support.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy mandeha ny charger | No AC input power; Blown fuse; Faulty connection. | Check AC power source and circuit breaker. Inspect input cable and connections. |
| Batterie tsy mi-charge | Incorrect battery connection; Battery deeply discharged; Faulty battery. | Verify DC output connections and polarity. Allow time for deeply discharged batteries to recover. Test battery condition. |
| Overheating / Shutdown | Insufficient ventilation; Overload. | Ensure clear airflow around the unit. Reduce load if possible. Allow unit to cool down. |
8. Famaritana
| endri-javatra | antsipirihany |
|---|---|
| Marika | Mastervolt |
| Anarana modely | ChargeMaster Plus 12/35-3 (Model Number: 44010250) |
| Nomput Output Voltage | 12 Volts DC (Requires AC input power, not specified in data) |
| Max Output Current | 25 Amps |
| Lanja entana | 5.5 kilao (eo ho eo. 2.5 kg) |
| Haben'ny entana (LxWxH) | 5.2 x 2.36 x 9.21 santimetatra (tokony ho 13.2 x 6 x 23.4 cm) |
| KEVITRA | plastika |
| loko | No Color (referring to the product's primary color, which is teal/green) |
| Daty azo alaina voalohany | Febroary 14, 2015 |
9. Warranty sy fanohanana
The Mastervolt ChargeMaster Plus 12/35-3 comes with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Mastervolt website.
For technical support, service, or spare parts, please contact Mastervolt customer service or your authorized dealer. Have your product model number (44010250) and serial number ready when contacting support.
Mastervolt Support: www.mastervolt.com/support