Knightsbridge JB003

Knightsbridge JB003 IP68 16A 3-Way Cable Connector Instruction Manual

Model: JB003 | Brand: Knightsbridge

1. Fampidirana

Thank you for choosing the Knightsbridge JB003 IP68 16A 3-Way Cable Connector. This manual provides essential information for the safe and effective installation, operation, and maintenance of your connector. Please read these instructions carefully before use and retain them for future reference.

The JB003 is designed to provide a robust, waterproof, and dustproof electrical connection for outdoor and demanding environments, ensuring reliable power distribution for various applications.

2. Information momba ny fiarovana

FAMPITANDREMANA: Electrical installations should only be carried out by a qualified electrician or competent person. Always disconnect the power supply before commencing any electrical work.

3. Vokatra mihoatraview

The Knightsbridge JB003 is a high-quality, durable 3-way, 3-pole inline T-connector designed for outdoor electrical connections. Its robust construction and IP68 rating make it ideal for harsh environments.

Knightsbridge JB003 IP68 3-Way Cable Connector

Figure 1: Knightsbridge JB003 IP68 3-Way Cable Connector. This image shows the black T-shaped connector with yellow sealing rings, designed for robust outdoor electrical connections.

Fampiasana natao:

This connector is suitable for various outdoor electrical applications, including:

4. Famaritana

MarikaKnightsbridge
Laharana modelyJB003 (Item Model Number: JBAV003)
Rating amin'izao fotoana izao16 Amps
BOKYtage Naoty450 Volts
IP RatingIP68 (2 bar)
Isan'ny Circuit3 (3-pole connection)
Savaivony taribyMin 5mm, Max 14mm
Compatible Cable TypeH07RNF 3G 0.75mm² - 4.0mm²
KEVITRAPA99, UL94-V0 (Plastic) with Silicon Sealing Gasket
ny terminalScrew Fix, Copper Nickel Plated
refy (L x W x H)Approx. 3.23 x 3.7 x 1.26 santimetatra (82 x 94 x 32 mm)
lanjaEo amin'ny 1.76 ounces (50g) eo ho eo
CertificationsCE, EN50262
Knightsbridge JB003 Dimensional Drawing

Figure 2: Dimensional drawing of the Knightsbridge JB003 connector, showing key measurements in millimeters.

5. Ny votoatin'ny fonosana

Ny fonosana dia tokony ahitana ireto singa manaraka ireto:

6. Fametrahana sy fametrahana

Follow these steps carefully to ensure a safe and watertight connection. Refer to the installation diagram (Figure 3) for visual guidance.

  1. Omano tariby: Ensure the power supply is disconnected. For each cable, strip the outer insulation to expose the inner conductors (Live, Neutral, Earth). Strip approximately 8-10mm of insulation from the ends of the individual conductors.
  2. Disassemble Connector: Unscrew the glands and locking nuts from each of the three entry points of the connector. Remove the internal seals and set them aside.
  3. Ampidiro ny tariby: Thread each cable through the gland, locking nut, and then through the corresponding entry point of the connector body. Ensure the cable passes through the internal seals correctly.
  4. Connect Wires: Insert the stripped ends of the Live, Neutral, and Earth wires into their respective screw terminals within the connector body. Ensure no stray strands are present and that the insulation reaches the terminal block. Tighten the terminal screws securely.
  5. Reassemble and Seal: Push the internal seals firmly into place around the cables at each entry point. Screw the locking nuts back onto the connector body, ensuring they are tight. Finally, screw the glands onto the locking nuts.
  6. Tighten Glands: Using an appropriate tool, tighten the glands to a torque of 2.5 Nm. This is crucial for maintaining the IP68 waterproof rating. Do not overtighten.
Knightsbridge JB003 Installation Diagram

Figure 3: Step-by-step installation diagram for the Knightsbridge JB003 connector, illustrating cable preparation, wire connection, and sealing procedures.

Knightsbridge JB003 in outdoor garden application

Figure 4: The Knightsbridge JB003 connector installed in an outdoor garden setting, demonstrating its use for connecting multiple cables in a T-configuration.

7. Fampandehanana

Once correctly installed and sealed, the Knightsbridge JB003 connector operates passively by providing a secure and waterproof junction for your electrical cables. There are no user-operable controls or settings on the connector itself. Ensure the connected electrical system is functioning as intended after installation.

8. Fikojakojana

To ensure the longevity and continued performance of your Knightsbridge JB003 connector, consider the following maintenance guidelines:

9. Famahana olana

If you encounter issues with your Knightsbridge JB003 connector, consider the following:

If problems persist, consult a qualified electrician or contact Knightsbridge customer support.

10. Warranty sy fanohanana

Specific warranty details for the Knightsbridge JB003 connector may vary by region and retailer. Please refer to your purchase documentation or the Knightsbridge official webtranokala hahazoana fampahalalana momba ny fiantohana farany indrindra.

For technical support, product inquiries, or warranty claims, please contact your retailer or Knightsbridge customer service directly. Contact information can typically be found on the manufacturer's webtoerana na fonosana vokatra.

Documents mifandraika - JB003

Preview Knightsbridge SK006 IP54 3-Gang Pop-Up Socket: Boky Fametrahana & Fikojakojana
Ity boky ity dia manome torolàlana feno momba ny fametrahana, fampandehanana ary fikojakojana ny Knightsbridge SK006 IP54 3-Gang Pop-Up Socket. Izy io dia mirakitra ny fepetra fiarovana, ny dingana fametrahana, ny torolalana amin'ny fampiasana, ny fampitandremana ary ny fampahalalana momba ny fiantohana.
Preview Knightsbridge SKR008 / SKR009A Installation and Maintenance Manual
Detailed installation and maintenance guide for Knightsbridge SKR008 and SKR009A electrical sockets. Includes safety precautions, step-by-step installation instructions, wiring diagrams, and warranty information.
Preview Knightsbridge Electrical Accessories Installation and Safety Guide
Comprehensive guide to the safe installation and operation of Knightsbridge electrical accessories, including sockets, USB chargers, dimmers, and switches. Covers wiring, safety precautions, and product specifications.
Preview Knightsbridge 8300XX Electrical Switch Installation and Maintenance Manual
This document provides installation and maintenance instructions for the Knightsbridge 8300XX electrical switch. It covers safety precautions, installation steps, general care, and warranty information.
Preview Knightsbridge XT468 Network Cable Tester Boky Fametrahana sy Fikojakojana
Torolàlana fametrahana sy fikojakojana ho an'ny Knightsbridge XT468 Network Cable Tester. Ity torolalana ity dia manome torolalana amin'ny fampiasana ny tester ho an'ny fifandraisana RJ45, RJ11, ary RJ12, ao anatin'izany ny diagrama tariby sy ny famahana olana.
Preview Knightsbridge EX00xx Extractor Fan Installation & Maintenance Manual
Fametrahana sy fikojakojana feno ho an'ny mpankafy mpanangona andiany Knightsbridge EX00xx (EX003T, EX004T, EX005T, EX006T). Ahitana torolàlana momba ny fiarovana, torolalana amin'ny tariby, fanitsiana famerana ary fampahalalana momba ny fiantohana ho an'ny fanamboarana sy fikarakarana mety.