1. Fampidirana
This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of your Fluke 362 200A AC/DC Clamp Meter. Please read this manual thoroughly before using the device to ensure proper functionality and safety.
The Fluke 362 is a compact and versatile clamp meter designed for measuring AC and DC current up to 200A, AC and DC voltage up to 600V, resistance up to 3000 Ω, and continuity. Its ergonomic design and robust construction make it suitable for various electrical measurement tasks.
2. Information momba ny fiarovana
WARNING: To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the product.
- Araho hatrany ny fepetra fiarovana eo an-toerana sy nasionaly.
- Do not use the meter if it is damaged or operating abnormally.
- Hamarino tsara fa eo amin'ny toerana marina ny switch function rehefa mandrefy.
- Aza mihatra mihoatra ny naoty voltage, araka ny marika eo amin'ny metatra, eo anelanelan'ny terminal na eo anelanelan'ny terminal sy ny tany.
- The Fluke 362 is rated for CAT III 600 V. This rating indicates suitability for measurements in distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, and socket outlets in the fixed installation, and industrial use equipment.
- Mitandrema rehefa miasa amin'ny voltagmihoatra ny 30 V AC RMS, 42 V peak, na 60 V DC. Ireo voltagmiteraka loza mitatao.
- Remove test leads from the circuit before opening the battery cover.
- Soloy ny bateria rehefa miseho ny famantarana ny bateria ambany mba hahazoana antoka fa marina ny famakiana.
3. Vokatra mihoatraview
The Fluke 362 clamp meter features a robust design for reliable performance in various environments. Familiarize yourself with its components:

Sary 1: Eo anoloana view of the Fluke 362 Clamp Meter, showing the display, function dial, jaw, and buttons.

Figure 2: The Fluke 362 Clamp Meter held in a gloved hand, illustrating its compact size and ergonomic design for single-hand operation.
singa fototra:
- Cl ankehitrinyamp valanorano: For non-contact AC/DC current measurements. Features an 18 mm triangular jaw for access in tight spaces.
- Dial miasa: Rotary switch to select measurement functions (AC/DC current, AC/DC voltage, fanoherana, fitohizana).
- LCD Display: Large, easy-to-read digital display for measurement results.
- Bokotra HOLD: Mampijanona ny famakiana ankehitriny eo amin'ny efijery.
- Bokotra ZERO: Used to clear the display for DC current measurements, compensating for any offset.
- Toerana fidirana: For connecting test leads for voltage, fandrefesana fanoherana ary fitohizana.
Lafin-javatra fototra:
- 200 A AC/DC current measurement capability.
- 600 V AC/DC voltage measurement capability.
- 3000 Ω resistance range.
- Continuity detection with audible indicator.
- Zero function for accurate DC measurements.
- Data hold function to capture readings.
- Large, clear display for easy viewing.
- Compact and lightweight design for one-hand operation.
- CAT III 600 V safety rating.
4. Fametrahana
4.1 Fametrahana bateria
The Fluke 362 is battery-powered. Although batteries are not included with all packages, they are required for operation. To install or replace batteries:
- Ensure the meter is turned OFF and no test leads are connected.
- Tadiavo ao ambadiky ny metatra ny fonon'ny fitoeran'ny bateria.
- Ampiasao ny tournevis mba hamahana ny visy mihazona ny fonony.
- Remove the cover and insert the required batteries, observing correct polarity (+/-).
- Replace the battery cover and tighten the screw(s).
4.2 Test Lead Connection
Ho an'ny voltage, resistance, and continuity measurements, connect the test leads to the input terminals:
- Insert the black test lead into the “COM” (common) terminal.
- Insert the red test lead into the “VΩ” (voltage/resistance) terminal.
5. Torolàlana miasa
5.1 Mamelona/Mamono
Rotate the function dial from the “OFF” position to any desired measurement function to power on the meter. To power off, rotate the dial back to the “OFF” position.
5.2 Fifidianana asa
Use the rotary function dial to select the desired measurement mode (e.g., A∼ for AC current, A— for DC current, V∼ for AC voltage, V— for DC voltage, Ω for resistance, or continuity).
5.3 Fandrefesana ny herin'aratra AC/DC (Clamp)
To measure current using the clamp valanorano:
- Rotate the function dial to A∼ (AC current) or A— (DC current).
- For DC current measurements, press the “ZERO” button to clear any offset before clamping.
- Sokafy ny clamp valanorano amin'ny fanindriana ny trigger.
- Enclose only one conductor within the jaw. Ensure the jaw is fully closed.
- Vakio ny sanda ankehitriny eo amin'ny efijery.
5.4 AC/DC Voltage Fandrefesana
Mandrefy voltage:
- Ampifandraiso ireo tariby fitsapana araka ny voalaza ao amin'ny Fizarana 4.2.
- Rotate the function dial to V∼ (AC voltage) or V— (DC voltagary).
- Ampifandraiso mifanitsy amin'ny faritra na singa tianao horefesina ireo fitaovana fitsapana.
- Vakio ny voltage sanda eo amin'ny efijery.
5.5 Fandrefesana fanoherana
Mba handrefesana ny fanoherana:
- Hamarino tsara fa tsy misy herinaratra intsony ny faritra na ny singa alohan'ny handrefesana ny fanoherana.
- Ampifandraiso ireo tariby fitsapana araka ny voalaza ao amin'ny Fizarana 4.2.
- Rotate the function dial to Ω (resistance).
- Ampifandraiso manerana ny singa ireo fitaovana fitsapana.
- Vakio ny sandan'ny fanoherana eo amin'ny fampisehoana.
5.6 Fitsapana mitohy
To perform a continuity test:
- Ataovy azo antoka fa tsy misy herinaratra ao amin'ny faritra na ny singa.
- Ampifandraiso ireo tariby fitsapana araka ny voalaza ao amin'ny Fizarana 4.2.
- Rotate the function dial to the continuity position (often shared with resistance, indicated by a speaker icon).
- Connect the test probes across the component or wire.
- The meter will emit an audible tone if continuity is detected (resistance below a certain threshold).
5.7 Zero Function (DC Measurements)
The “ZERO” button is primarily used for DC current measurements. Before taking a DC current reading, with the clamp jaw open and no conductor inside, press the “ZERO” button to eliminate any residual offset and ensure accurate readings.
5.8 Fihazonana angon-drakitra
Press the “HOLD” button to freeze the current reading on the display. This is useful for taking readings in hard-to-see locations. Press “HOLD” again to release the reading and return to live measurement.
6. Fikojakojana
6.1 Fanadiovana
To clean the meter, wipe it with a damp lamba sy savony malefaka. Aza mampiasa akora manimba na ranoka solvent. Ataovy azo antoka fa maina tanteraka ny metatra alohan'ny hampiasana azy.
6.2 Fanoloana bateria
When the low battery indicator appears on the display, replace the batteries promptly to maintain measurement accuracy. Refer to Section 4.1 for battery installation instructions.
6.3 Fitehirizana
If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in a dry, cool environment, away from direct sunlight and extreme temperatures.
7. Famahana olana
If you encounter issues with your Fluke 362, refer to the table below for common problems and solutions:
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Meter does not power on or display is blank. | Batterie maty na diso napetraka. | Jereo ny polarity bateria na soloy ny bateria. |
| Vakiteny tsy marina. | Low battery, incorrect function selected, external interference, or un-zeroed DC current. | Replace batteries, select correct function, move away from strong electromagnetic fields, or use the ZERO function for DC current. |
| Continuity tone is too low or inaudible. | Noisy work environment. | Relocate to a quieter area or rely on the visual display for continuity indication. |
| “OL” (Overload) displayed. | Measurement exceeds the meter’s range. | Ensure the measurement is within the specified range for the selected function. |
If the problem persists after attempting these solutions, contact Fluke customer support.
8. Famaritana
| fikirana | famaritana |
|---|---|
| Marika | Fluke |
| MODELY | 362 |
| Range ankehitriny | 200 A |
| DC Range ankehitriny | 200 A |
| AC Voltage Range | 600 V |
| DC Voltage Range | 600 V |
| Range fanoherana | 3000 Ω |
| Naoty fiarovana | CAT III 600 V |
| Fanokafana valanorano | 18 mm |
| Loharanon-kery | Battery Powered |
| refy (L x W x H) | 7.87 x 1.57 x 3.94 santimetatra |
| Lanja entana | 14.1 ounces (400 grama) |
| UPC | 095969672191 |
| Laharana modely | 4345498 |
9. Warranty sy fanohanana
Fluke products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Fluke website. Tehirizo ny tapakila fividiananao ho porofon'ny fividianana.
For technical support, service, or calibration, please contact Fluke customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your model number (Fluke 362) and serial number (if applicable) ready.