Field Controls 6MG1

Field Controls 6-inch MG-1 Gas Draft Control/Regulator

Model: 6MG1

Field Controls MG-1 Gas Draft Control Regulator

An image showing the Field Controls MG-1 Gas Draft Control Regulator, a circular metal device with a clear cover and a chain for adjustment.

Sava lalana

This manual provides essential information for the safe and effective use of your Field Controls 6-inch MG-1 Gas Draft Control/Regulator. This device is designed to provide precise and accurate control of drafts in gas-fired heating systems, particularly in applications where higher draft levels are required than those managed by standard draft diverters.

Fametrahana sy fametrahana

Fiarovana voalohany: Installation of gas appliances and their components should only be performed by qualified and licensed professionals. Improper installation can lead to serious injury, property damage, or death. Always consult local codes and regulations.

The Field Controls MG-1 is designed for installation on the flue pipe of a gas appliance. Key dimensions for this model include:

Ensure the installation location provides adequate clearance for the regulator's operation and future maintenance. The device should be securely mounted to prevent movement or vibration.

Fitsipika miasa

The MG-1 Gas Draft Control/Regulator automatically adjusts to maintain a consistent draft in the flue, optimizing combustion efficiency and safety. It operates by opening or closing a damper to regulate the flow of combustion gases. This precise control is crucial for gas appliances that require specific draft conditions for optimal performance and to prevent issues such as incomplete combustion or excessive heat loss.

The regulator's design allows for fine-tuning of the draft, ensuring that the appliance operates within its specified parameters, even when external conditions (like wind or atmospheric pressure) fluctuate.

fikarakarana

Regular inspection and maintenance are essential to ensure the continued safe and efficient operation of your Field Controls MG-1 Gas Draft Control/Regulator. It is recommended that a qualified technician perform annual inspections as part of your heating system's routine maintenance.

Do not attempt to lubricate or modify the internal components of the regulator unless specifically instructed by the manufacturer.

Fanamboarana

If you suspect an issue with your gas draft control, it is crucial to contact a qualified HVAC technician immediately. Attempting to diagnose or repair gas appliance components without proper training and tools can be dangerous.

Common indicators of a potential issue might include:

A technician can assess the draft conditions, inspect the regulator, and perform any necessary adjustments or replacements.

fepetra arahana

famaritanaantsipirihany
mpanamboatraFanaraha-maso ny saha
Laharan'ny ampahany02724001
Laharana modely6MG1
Lanja entana2.2 kg
Ny refin'ny vokatra6 x 3 x 6 santimetatra
Anisan'ny singaGas Draft Control
ASINB00ICS1GUA
Daty misy voalohanyFebroary 10, 2014

Warranty Information

Specific warranty details for the Field Controls 6-inch MG-1 Gas Draft Control/Regulator are not provided in this document. Please refer to the product packaging or the official Field Controls webtranonkala hahazoana ny fampahalalana farany momba ny garantie.

Fanohanana sy Fifandraisana

For technical assistance, installation questions, or service inquiries, please contact Field Controls directly or consult a qualified HVAC professional.

You can find more information about Field Controls products and support on their official website or by visiting their Fivarotana marika Amazon.

Documents mifandraika - 6MG1

Preview Field Controls CK-61, 62, 63 Oil Fired System Wiring Diagrams
Detailed wiring diagrams for Field Controls CK-61, 62, and 63 oil-fired single unit systems, including power venter, draft inducer, primary control, and ignition transformer connections.
Preview Field Controls Power Venter PVG-100, PVG-300, PVG-600 Installation Manual
This installation manual provides detailed instructions for the Field Controls Power Venter models PVG-100, PVG-300, and PVG-600. It covers unit specifications, sizing calculations, safety precautions, installation procedures, wiring diagrams, system checks, maintenance, and troubleshooting for HVAC applications.
Preview Fanaraha-maso ny saha SWG/CV Power Venter: Fametrahana, Famaritana ary famaritana
Torolàlana feno ho an'ny Field Controls SWG sy ComboVent (CV) Power Venters, mirakitra ny endri-javatra vokatra, ny habeny, ny fametrahana, ny fandrindrana ny rafitra, ny fivoahana, ny fitaovana fanaraha-maso, ny fananganana rafitra ary ny fikojakojana. Ahitana famaritana amin'ny antsipiriany sy torohevitra momba ny famahana olana.
Preview Flue Sentinel Millivolt Fireplace Damper Installation Manual | Field Controls
Installation guide for the Flue Sentinel Millivolt Fireplace Damper (FSM Series) by Field Controls. Covers specifications, dimensions, installation procedures, wiring diagrams, sequence of operation, troubleshooting, and maintenance for gas fireplaces.
Preview Field Controls Trio Plus Air Purifier User Manual
Comprehensive user manual for the Field Controls Trio Plus air purifier, detailing safety precautions, product overview, operation instructions, maintenance, filter and UVC lamp replacement, troubleshooting, and transportation/storage conditions.
Preview Field Controls S2000 & S2020 Power Humidifier: Installation & Owner Manual
Comprehensive installation instructions and owner's manual for Field Controls S2000 (120VAC) and S2020 (240VAC) electronic steam power humidifiers. Learn how to install, operate, and maintain your unit for optimal performance in forced air systems.