1. Fampidirana
The Fieldpiece SPK3 is a versatile dual-temperature thermometer designed for HVACR professionals. It combines a folding rod temperature probe for in-duct measurements with an 8:1 infrared (IR) gun for non-contact surface temperature readings. This device features a convenient flip display, Max/Min, Hold, and T1-T2 functions, and a robust design for field use.

Image 1.1: The Fieldpiece SPK3 thermometer, showing its folding rod probe extended and the infrared sensor. The display shows temperature readings.
2. Fametrahana
2.1 Fametrahana bateria
- Tadiavo ny fonon'ny efitrefitra bateria ao ambadiky ny fitaovana.
- Use a small screwdriver or coin to open the battery compartment.
- Insert two (2) AAA batteries, ensuring correct polarity (+/-). The batteries are included with the device.
- Soloy ny fonon'ny efitry ny bateria ary arovy izany.
2.2 Herin'ny voalohany
Tsindrio ny ON/OFF button to power on the device. The display will illuminate, and the thermometer will be ready for use.
3. Torolàlana miasa
3.1 Fampandehanana ankapobeny
- Herim-batana / maty: Tsindrio ny ON/OFF bokotra hamelomana na hamonoana ilay fitaovana.
- Fifantenana vondrona: Tsindrio ny ° C / ° F button to switch between Celsius and Fahrenheit temperature units.
- Jiro lamosina: The display is backlit for visibility in low-light conditions.
3.2 Folding Rod (ROD) Mode
The folding rod probe is designed for accurate in-duct temperature measurements.
- Deploying the Probe: Gently unfold the rod probe from the main body of the thermometer. Detents will lock the probe into various open positions, allowing for partial or full extension.
- In-Duct Measurement: Insert the piercing tip of the rod into the ductwork. The rod hook allows the SPK3 to hang hands-free from registers or ductwork, providing stable readings.
- Fampisehoana orientation: The backlit display automatically flips its orientation when the unit is hung or positioned in ROD mode, ensuring readings are always upright.
3.3 Infrared (IR) Mode
The 8:1 infrared gun provides quick, non-contact surface temperature measurements.
- Activating IR: Point the infrared sensor (located at the top of the unit) towards the target surface.
- fandrefesana: Tsindrio ary hazòny ny IR button to take a reading. The temperature will be displayed on the screen. Release the button to hold the reading.
- Laza-lavitra amin'ny toerana: The 8:1 ratio means that at a distance of 8 inches, the measurement spot size is 1 inch. Ensure you are close enough to the target for accurate readings.
3.4 Fampiasa mandroso
- MAX / MIN: Tsindrio ny MAX/MIN bokotra to view the maximum or minimum temperature recorded during a measurement session.
- HATAO: Tsindrio ny MANOHANA button to freeze the current temperature reading on the display. Press again to release.
- T1-T2: The SPK3 can quickly calculate the temperature difference between two readings (T1-T2) using either IR or ROD mode. Refer to the on-screen prompts for specific instructions on using this function.
4. Fikojakojana
4.1 Fanadiovana
To clean the SPK3, wipe the exterior with a damp cloth. Do not use abrasive cleaners or immerse the unit in water. Ensure the infrared lens and probe tip are kept clean for accurate measurements.
4.2 Fanoloana bateria
When the battery indicator appears on the display, replace the AAA batteries as described in Section 2.1.
4.3 Fitehirizana
When not in use, fold the rod probe back into the body of the thermometer for protection. Store the unit in a dry environment, away from extreme temperatures and direct sunlight.
5. Famahana olana
- Tsy misy efijery/fitaovana tsy mirehitra:
- Check battery installation and ensure correct polarity.
- Soloy ny bateria vaovao.
- Inaccurate Readings (ROD Probe):
- Hamarino tsara fa madio ny tendron'ny fitaovana ary tsy misy loto.
- Allow sufficient time for the probe to stabilize to the measured temperature.
- Verify the probe is fully inserted into the measurement area.
- Inaccurate Readings (IR Gun):
- Ensure the IR lens is clean.
- Maintain the correct distance-to-spot ratio (8:1).
- Avoid measuring highly reflective surfaces, as IR thermometers may provide inaccurate readings on such materials.
- Display Not Flipping:
- Ensure the unit is in ROD mode and positioned appropriately for the automatic flip feature to engage.
6. Famaritana
| endri-javatra | famaritana |
|---|---|
| Anarana modely | SPK3 |
| Endri-javatra manokana | Dual Probe, Non-Contact |
| Karazana fampisehoana | Hafanàm-po |
| Teknolojia fifandraisana | Infrared |
| Loharanon-kery | Battery Powered (2 AAA batteries, included) |
| Lanja entana | 5.3 oz |
| Halavan'ny entana | 5 santimetatra |
| Famaritana ny maripana ambony | 932 degre Fahrenheit |
| Naoty maripana ambany kokoa | 32 degre Fahrenheit |
| Fotoam-pamaliana | 500 Miliseconds |
| Immersion Depth (Rod) | 3.75 santimetatra |
| Fitaovana ivelany | Stainless Steel, Aluminum, Polypropylene |
| Met | CE, FCC, NIST |
| Salanisan'ny fiainana bateria | 3 ora |
7. Warranty & Fanohanana
7.1 Fampahalalana momba ny fiantohana
The Fieldpiece SPK3 comes with a Garantie mpanamboatra 1 taona manomboka amin'ny datin'ny fividianana. Ity fiantohana ity dia manarona ny lesoka amin'ny fitaovana sy ny asa amin'ny fampiasana mahazatra. Azafady, tehirizo ny porofon'ny fividiananao ho an'ny fitakiana fiantohana.
7.2 Fanohanana ny mpanjifa
For technical assistance, troubleshooting, or warranty inquiries, please contact Fieldpiece customer support. Visit the official Fieldpiece webtranokala ho an'ny antsipiriany momba ny fifandraisana sy loharano fanampiny.
Loharano an-tserasera: www.fieldpiece.com