Dante NG.BVS.CR

Dante Products NG.BVS.CR Universal Log Lighter Combo Kit User Manual

Model: NG.BVS.CR

Sava lalana

This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of the Dante Products NG.BVS.CR Universal Log Lighter Combo Kit. This kit is designed to provide a convenient and clean method for igniting natural gas logs in a fireplace.

Vakio tsara ny torolalana rehetra alohan'ny hametrahana sy hampiasana. Tehirizo ity boky torolalana ity ho fanondroana ho avy.

Vokatra singa

The Dante Universal Log Lighter Combo Kit includes the following components:

Dante Products NG.BVS.CR Universal Log Lighter Combo Kit components: a chrome key, a chrome floor plate, a long gas log lighter tube with a mixer, and a brass T-fitting.

Sary 1: TAPITRAview of the Dante Universal Log Lighter Combo Kit components. This image displays all parts included in the kit: a chrome-plated key for operating the valve, a circular chrome floor plate that covers the valve opening, a long metal tube which is the natural gas log lighter with an attached mixer at one end, and a brass T-fitting for gas line connection.

  • Natural Gas Log Lighter: A 20-inch long tube with an integrated air/gas mixing chamber, designed for efficient gas combustion.
  • Quarter-Turn Ball Valve: A straight 1/2-inch valve for controlling gas flow.
  • Chrome Floor Plate: A decorative zinc die-cast, chrome-plated plate to cover the valve opening.
  • 3-Inch Key: A zinc die-cast, chrome-plated key for operating the quarter-turn ball valve.
  • Brass T-Fitting: For connecting the gas supply line.

Fametrahana sy fametrahana

fampahalalana manan-danja momba ny fiarovana: Installation must be performed by a qualified professional in accordance with all local codes and regulations. Ensure the main gas supply is turned off before beginning installation.

  1. Prepare Fireplace: Ensure the fireplace is clean and free of debris. Identify the location for the gas line connection.
  2. Connect Gas Line: Connect the natural gas supply line to the brass T-fitting. Use appropriate pipe sealant on all threaded connections to prevent leaks.
  3. Install Ball Valve: Attach the quarter-turn ball valve to the T-fitting. Ensure it is securely tightened.
  4. Position Log Lighter: Connect the natural gas log lighter tube to the ball valve. Position the log lighter within the fireplace, ensuring the burner holes face upwards and are clear of any obstructions. The log lighter measures 20 inches from end to end with the mixer attached.
  5. Install Floor Plate: Place the chrome floor plate over the valve stem opening in the hearth or floor, ensuring it sits flush.
  6. Fitsapana ho an'ny leak: After all connections are made, slowly turn on the main gas supply. Apply a leak detection solution (soapy water) to all connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, tighten connections, and re-test. Do not proceed until all leaks are resolved.
  7. Place Gas Logs: Arrange your gas logs over the log lighter, ensuring they do not block the burner holes or the air/gas mixing chamber. Allow adequate air circulation around the log lighter.

Torolàlana miasa

Fiarovana voalohany: Always ensure proper ventilation when operating gas appliances. Never leave an active flame unattended.

  1. Open Damper: Ensure the fireplace damper is fully open before lighting to allow for proper ventilation and prevent smoke from entering the room. The log lighter heats the chimney quickly, causing the fireplace to draw smoke immediately up the chimney.
  2. Ampidiro ny fanalahidy: Insert the 3-inch chrome key into the quarter-turn ball valve stem.
  3. Turn On Gas: Slowly turn the key to the "ON" position (typically a quarter-turn). You should hear the sound of gas flowing.
  4. Ignite Gas: Immediately use a long fireplace lighter or match to ignite the gas flowing from the log lighter. The flame should be visible and consistent.
  5. Ahitsio lelafo: Once the logs are ignited, you can adjust the flame intensity by partially turning the key towards the "OFF" position. For full ignition of logs, allow the log lighter to burn for a few minutes until the logs are sufficiently lit.
  6. Turn Off Log Lighter: Once the gas logs are burning steadily, turn the key to the "OFF" position to extinguish the log lighter flame. Remove the key.

fikarakarana

The Dante Universal Log Lighter Combo Kit requires minimal maintenance. Regular inspection is recommended to ensure safe and efficient operation.

  • Fanaraha-maso isan-taona: Have a qualified professional inspect the gas connections and the log lighter annually for any signs of wear, corrosion, or leaks.
  • Clean Burner Holes: Periodically check the burner holes on the log lighter tube for any obstructions (e.g., soot, debris). Use a small brush or wire to clear them if necessary. Ensure the gas supply is off before cleaning.
  • Ireo singa madio: Wipe down the chrome floor plate and key with a soft, damp cloth to maintain their appearance. Avoid abrasive cleaners.

Fanamboarana

OLANA Antony mety hitranga vahaolana
No gas flow or weak flame.
  • Esory ny famatsiana entona lehibe.
  • Valve not fully open.
  • Gas line obstruction.
  • Check main gas supply valve.
  • Ensure key is fully turned to "ON".
  • Contact a qualified technician to inspect gas lines.
Nahatsikaritra fofona entona.
  • Gas leak at connections.
  • Tsy mihidy tanteraka ny valva.
  • Immediately turn off gas supply. Ventilate area. Apply leak detection solution to all connections. Tighten or repair as needed. If smell persists, evacuate and call gas company.
  • Ensure key is fully turned to "OFF" and removed.
Log lighter does not ignite.
  • No gas flow (see above).
  • Ignition source not applied quickly enough.
  • Burner holes obstructed.
  • Follow steps for "No gas flow".
  • Apply ignition source immediately after turning on gas.
  • Clean burner holes (ensure gas is off).

Raha tsy mamaha ny olana ireo dingana famahana olana dia mifandraisa amin'ny teknisianina matihanina.

fepetra arahana

Laharana modely NG.BVS.CR
Marika Dante Products
Karazana solika Entona voajanahary (NG)
Log Lighter Length 20 inches (end to end with mixer)
BTU Rating 30,000 BTU
Ukana valva 1/2-inch (straight quarter-turn ball valve)
Material (Key & Floor Plate) Zinc Die-Cast, Chrome Plated
Dimensions ankapobeny 24 x 3 x 3 santimetatra
Lanja entana 3 kilao
Ilaina ny fivoriambe ENY
Ilaina ny bateria tsy misy

Warranty Information

The Dante Products NG.BVS.CR Universal Log Lighter Combo Kit comes with a Garantie 1 taona voafetra manomboka amin'ny datin'ny fividianana.

This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repairs. For warranty claims, please retain your proof of purchase and contact Dante Products customer support.

Fanohanana ny mpanjifa

For technical assistance, replacement parts, or warranty inquiries, please contact Dante Products customer support.

Please have your model number (NG.BVS.CR) and proof of purchase available when contacting support.

For additional information and resources, you may visit the official Dante Products website (if available, link would be here).

Mpanamboatra: Dante Products

Documents mifandraika - NG.BVS.CR

Preview Dante Electric Fireplace Heater Boky Torolàlana ho an'ny tompony sy ny fametrahana
Torolàlana feno ho an'ny tompony sy ny fametrahana ho an'ny Dante Flat Panel Electric Fireplace Heater (Model EFW-TJ42A), mirakitra ny fiarovana, ny fandidiana, ny fivoriambe ary ny famahana olana.
Preview Dante famahana olana FAQ: Vahaolana ho an'ny olana amin'ny tambajotra audio mahazatra
Ity torolalana FAQ feno ity dia manome vahaolana sy fanazavana momba ny olana mahazatra atrehana amin'ny tambajotra audio Dante, anisan'izany ny Dante Controller sy Dante Virtual Soundcard. Ianaro ny fomba famahana olana mifandraika amin'ny fahitana ny fitaovana, ny fikorontanan'ny feo, ny fampifanarahana ny famantaranandro, sy ny maro hafa.
Preview Dante 2CH USB Audio Encoder/Decoder with POE: User Manual & Specifications
Comprehensive user manual for the Dante 2CH USB Audio Encoder/Decoder with POE. Learn about features, specifications, operation, and application examples ho an'ny tambajotra audio matihanina.
Preview Dante 2CH Analog Audio Encoder with POE | User Manual & Specifications
User manual for the Dante 2CH Analog Audio Encoder with POE, detailing its features, specifications, operation, and application examples ho an'ny tambajotra audio matihanina.
Preview DANTE DMIC 3 Dante Microphone Specifications and Features
Detailed specifications and features of the DANTE DMIC 3 Dante microphone, including directivity, frequency response, power supply, and dimensions. Learn about its PoE capabilities and Dante network integration for professional audio applications.
Preview Dante AVIO Install: 2-Channel Analog Adapters for Pro AV Integrators
Discover the Dante AVIO Install line of 2-channel analog adapters, designed for seamless integration of analog audio equipment into Dante-enabled Pro AV systems. Learn about features like Euroblock terminals, the ClickGrid mounting system, and superior audio performance.