Dwyer A3000 Series

Boky Torolalana ho an'ny Dwyer Photohelic Series A3000 momba ny Famantaran-tsindry/Fitaovana fandrefesana tsindry

Model: A3000 Series

1. Fampidirana

The Dwyer Photohelic Series A3000 Pressure Switch/Gauge is a versatile instrument that combines the functions of a precise pressure gauge with highly repeatable pressure switches. Utilizing the proven Magnehelic gauge design, this device accurately measures and controls positive, negative, or differential pressures of air and compatible gases.

It features two phototransistor-actuated, DPDT relays for low/high limit control, allowing for precise system management. Set points are easily adjustable via knobs located on the gauge face. The continuous gauge reading remains unaffected by switch operation, even during power loss, ensuring reliable monitoring.

2. endri-javatra

  • Combined Functionality: Operates as both a pressure gauge and a pressure switch.
  • Precise Measurement: Employs the Magnehelic gauge design for accurate pressure readings.
  • Dual Control Relays: Includes two phototransistor-actuated DPDT relays for low/high limit control.
  • Adjustable Set Points: Easy-to-adjust set point indicators via front-mounted knobs.
  • Continuous Reading: Gauge reading is continuous and independent of switch operation or power status.
  • Optical Limit Switches: Utilizes optical limit switches for enhanced reliability and extended service life.
  • Variable Deadband: Set points can be interlocked to provide a variable deadband, suitable for fan or damper control.
  • Fanorenana matanjaka: Features a clear polycarbonate plastic cover and a light shield to protect internal components and ensure clear visibility.

3. Fametrahana sy fametrahana

Proper installation is crucial for the accurate and reliable operation of your Photohelic Switch/Gauge. Refer to the detailed wiring diagrams and mounting instructions provided with your specific model for complete guidance.

3.1 Fametrahana

The unit is designed for vertical position calibration. Ensure the mounting surface is stable and free from excessive vibration. Secure the gauge using appropriate fasteners through the designated mounting holes.

3.2 Fifandraisana fanerena

Connect pressure lines to the appropriate ports on the gauge. Ensure all connections are sealed properly to prevent leaks, which can affect measurement accuracy. The gauge is suitable for air and compatible gases.

3.3 Fifandraisana elektrika

Connect the power supply and control circuits to the DPDT relays as per the electrical schematic. Ensure all wiring complies with local electrical codes and safety standards. The optical limit switches are designed for reliability and precise switching accuracy.

Dwyer Photohelic Series A3000 Pressure Switch/Gauge with clear cover, showing internal components, gauge face, and control knobs.

Sary 1: Dwyer Photohelic Series A3000 Pressure Switch/Gauge. This image displays the device with its clear polycarbonate cover, revealing the internal circuitry, the pressure gauge face calibrated for vertical position, and the two set point adjustment knobs labeled "ZERO". The gauge face indicates a maximum pressure of 25 PSIG.

4. Fampandehanana

4.1 Herinaratra

Once installed and wired, apply power to the unit. The gauge pointer will indicate the current pressure.

4.2 Fanitsiana aotra

Before operation, ensure the gauge reads zero when no pressure is applied. Use the "ZERO" adjustment screw (typically located on the front cover or near the bottom of the gauge face) to calibrate the pointer to zero.

4.3 Setting Control Points

  1. Identify the two set point knobs on the front of the gauge. These control the low and high limit switches.
  2. Rotate the desired knob to move its corresponding red set point indicator to the required pressure value on the gauge face.
  3. When the actual pressure (indicated by the main pointer) crosses a set point indicator, the associated DPDT relay will actuate, triggering the connected control circuit.
  4. The individual set point deadband is approximately one pointer width, which is less than 1% of the full scale.
  5. For applications requiring a variable deadband, the set points can be interlocked according to specific wiring diagrams.

4.4 Reading the Gauge

The gauge provides a continuous visual indication of the measured pressure. The scale is typically in inches of water column (WC) or pounds per square inch (PSIG), depending on the model. For example, the gauge face shown in Figure 1 indicates a range up to 0.50 inches of water, with markings at .20, .30, .40, and .50.

5. Fikojakojana

The Dwyer Photohelic Switch/Gauge is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

  • Fanadiovana: Keep the exterior of the gauge clean. Use a soft, damp cloth to wipe the clear cover. Avoid abrasive cleaners or solvents.
  • Fanamarinana calibration: Periodically verify the zero point and accuracy of the gauge using a known pressure source. Recalibrate if necessary.
  • Fifandraisana Integrity: Inspect all pressure and electrical connections for tightness and signs of wear or corrosion.
  • Fepetra ara-tontolo iainana: Ataovy izay hahazoana antoka fa ao anatin'ny mari-pana sy ny hamandoana voafaritra ny tontolo iainana ampiasaina mba hisorohana ny fahasimban'ny singa anatiny.

6. Famahana olana

If you encounter issues with your Photohelic Switch/Gauge, consider the following common troubleshooting steps:

  • No Gauge Reading:
    • Check pressure connections for leaks or blockages.
    • Verify that pressure is being applied to the correct ports.
  • Incorrect Gauge Reading:
    • Perform a zero adjustment.
    • Check for proper calibration against a known standard.
    • Ensure the gauge is mounted in a vertical position as calibrated.
  • Switches Not Actuating:
    • Verify electrical power to the unit.
    • Check wiring to the DPDT relays.
    • Ensure set points are correctly positioned relative to the current pressure.
    • Inspect optical limit switches for any obstructions or damage.
  • Fihetseham-po miato:
    • Hamarino raha misy fifandraisana elektrika simba.
    • Miantoka famatsiana herinaratra azo antoka.
    • Verify environmental conditions are stable and within operating limits.

If problems persist, contact Dwyer technical support for assistance.

7. Famaritana

fikiranasarobidy
Laharana modelyA3001AV (Specific model example)
FanerenaVarious, from 0-.25" WC up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar)
Max. Fanerena miasaStandard models: 25 psig (1.7 bar); Options: 35 (2.4) or 80 (5.5 bar) psig; 36000S models: 6000 psig (413 bar)
Karazana SwitchTwo phototransistor actuated, DPDT relays
Set Point DeadbandLess than 1% of full scale (one pointer width)
Media CompatibilityRivotra sy entona mifanentana
KEVITRAPlastic (cover)
Lanja entana4.7 kilao (eo ho eo)
mpanamboatraDwyer Instruments

8. Warranty sy fanohanana

For warranty information, technical support, or service inquiries, please contact Dwyer Instruments directly. Refer to the official Dwyer website or your purchase documentation for the most current contact details and warranty terms.

Ny sandan'ny anjara Dwyer Instruments, Inc.
www.dwyer-inst.com

Documents mifandraika - Série A3000

Preview Dwyer Series A3000 Photohelic Differential Pressure Switch/Gage User Guide
User's guide for the Dwyer Series A3000 Photohelic Differential Pressure Switch/Gage, detailing its specifications, installation, electrical connections, and maintenance.
Preview Dwyer Magnehelic® Differential Pressure Gage (HP/MP) - Specifications & Instructions
Technical specifications, installation, and operating instructions for Dwyer's Magnehelic® High and Medium Pressure Differential Pressure Gages (Bulletin A-27-HP-MP). Includes model details, accuracy, temperature range, mounting, connections, and accessories.
Preview Manometra Tsindry Diferensiala Hidrônika Tsy Misy Tambajotra Dwyer Series 490W: Torolàlana Fametrahana sy Fampiasana
Torolàlana feno ho an'ny Manometra Tsindry Diferensiala Hidrônika Tsy Misy Tariby Dwyer Series 490W, mandrakotra ny famaritana, ny fametrahana, ny fampiasana, ny famahana olana ary ny fikojakojana. Ahitana transducers tsy misy tariby ho an'ny fandanjalanjana marina ny rafitra hidrônika.
Preview Dwyer Series 616KX Differential Pressure Transmitter - Torolalana fanombohana haingana
Torolàlana fanombohana haingana ho an'ny Dwyer Series 616KX Differential Pressure Transmitter, mandrakotra ny fametrahana, ny tariby ary ny calibration aotra. Ahitana diagrama wiring ho an'ny fanamafisana tariby 2 sy 3 tariby.
Preview Dwyer Series 616KX Differential Pressure Transmitter Torolàlana ho an'ny mpampiasa
Torolàlana ho an'ny mpampiasa ho an'ny Dwyer Series 616KX Differential Pressure Transmitter, amin'ny antsipiriany ny fametrahana, ny famaritana, ny fifandraisana elektrônika, ny fampandehanana, ny fanitsiana aotra, ny fanamafisam-peo mivoaka, ny fitandremana, ny fikojakojana ary ny fampahalalana momba ny fiantohana.
Preview Dwyer Series 616KX Differential Pressure Transmitter Torolàlana ho an'ny mpampiasa
User's guide for the Dwyer Series 616KX Differential Pressure Transmitter, covering installation, specifications, electrical connections, zero adjustment, output signal changes, precautions, and warranty information.