YASKAWA CIMR-VU4A0011FAA

YASKAWA V1000 Series AC Drive User Manual

Model: CIMR-VU4A0011FAA

Sava lalana

This manual provides essential information for the safe and effective use of the YASKAWA V1000 Series AC Drive, model CIMR-VU4A0011FAA. The V1000 is a compact, high-performance variable frequency drive designed for a wide range of industrial applications, offering precise motor control and energy efficiency. Please read this manual thoroughly before installation, operation, or maintenance.

Yaskawa V1000 AC Drive, main view

Figure 1: Yaskawa V1000 AC Drive, showing the main unit with its grey casing and heat sink fins.

Information momba ny fiarovana

Always observe the following safety precautions to prevent injury, damage to equipment, or property loss. This drive contains high voltage components and should only be handled by qualified personnel.

Hametraka

1. Famoahana sy fisafoana

Carefully remove the drive from its packaging. Inspect the unit for any signs of damage that may have occurred during shipping. Verify that all components listed in the packing list are present.

Yaskawa V1000 AC Drive with instruction manual

Figure 2: The Yaskawa V1000 AC Drive unit shown alongside its accompanying instruction manual, still in its plastic packaging.

2. fitomboan'ny

Mount the drive vertically on a flat, stable surface. Ensure adequate clearance for ventilation around the unit. Refer to the dimensions provided in the specifications section for proper spacing. Avoid mounting in direct sunlight or near heat sources.

3. Tariby

All wiring must comply with national and local electrical codes. Use appropriate wire gauges for power, motor, and control circuits. Ensure proper grounding of the drive chassis and motor frame.

ambany view of Yaskawa V1000 AC Drive

Sary 3: Ambany ambany view of the Yaskawa V1000 AC Drive, showing the heat sink fins and mounting points, crucial for proper ventilation and installation.

4. Power-Up voalohany

Before applying power, double-check all wiring connections. Ensure no loose wires or foreign objects are present. Apply power and observe the drive's display. The drive should power on and display its default status or a ready message.

fandidiana

1. Fampandehanana fototra

The V1000 drive can be operated via its built-in keypad, external control terminals, or serial communication. For basic operation using the keypad:

  1. Tsindrio ny RUN button to start the motor.
  2. Tsindrio ny MIJANÒNA bokotra hampijanonana ny motera.
  3. Ampiasao ny AVY AVY arrow keys to adjust the output frequency (motor speed) if in frequency reference mode.

2. Famaritana parameter

The drive's behavior is configured through various parameters. Access the parameter menu via the keypad. Key parameters include:

Refer to the comprehensive parameter list in the full YASKAWA V1000 technical manual for detailed descriptions and settings.

fikarakarana

Regular maintenance ensures optimal performance and extends the lifespan of your V1000 AC Drive. Always disconnect power before performing any maintenance.

Fanamboarana

This section provides guidance for common issues. For detailed fault codes and advanced troubleshooting, consult the full YASKAWA V1000 technical manual.

SymptomAntony mety hitrangaHetsika fanitsiana
Tsy mandeha ny kapila mafyTsy misy herinaratra miditra; Fiarovana mipoaka; Fahasimbana anatinyCheck power supply; Inspect fuses; Contact support if internal fault suspected.
Tsy mandeha ny moteraIncorrect wiring; Parameter settings; External stop signal activeVerify wiring (motor/control); Check parameter settings (e.g., frequency reference, run command source); Ensure no active stop signals.
Overcurrent fault (OC)Motor overload; Short circuit in motor/cables; Rapid acceleration/decelerationCheck motor load; Inspect motor and cables for damage; Increase acceleration/deceleration times.
Overvoltage fault (OV)Regenerative energy from motor; High input voltageIncrease deceleration time; Install braking resistor if necessary; Verify input voltage.

fepetra arahana

Key technical specifications for the YASKAWA V1000 AC Drive, model CIMR-VU4A0011FAA:

fikiranasarobidy
Laharana modelyCIMR-VU4A0011FAA
Fampidirana VoltageAC 3-Phase 380-480V
Fampidirana matetika50/60 Hz
Herinaratra fidirana (Nomeraina)14.0A (380V) / 10.4A (480V)
Output VoltageAC 3-Phase 0-480V
Habetsahan'ny Output Frequency0-400 Hz
Output Current (Rated)11.1A (380V) / 9.2A (480V)
Mass / Weight2.6 kg (5.73 lbs eo ho eo)
Naoty enclosureIP20
mpanamboatraYASKAWA
Firenena nihavianaJapana
ASINB008HQ5TP0
Product label of Yaskawa V1000 AC Drive showing model and electrical specifications

Figure 4: Detailed product label of the Yaskawa V1000 AC Drive, displaying the model number, input/output electrical ratings, and manufacturing information.

Warranty sy fanohanana

YASKAWA products are manufactured to high standards and typically come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty documentation included with your purchase or visit the official YASKAWA website.

For technical support, service, or to inquire about replacement parts, please contact YASKAWA customer service or an authorized YASKAWA distributor. Provide your product model number (CIMR-VU4A0011FAA) and serial number when seeking assistance.

You can find more information and contact details on the official YASKAWA webtranokala: www.yaskawa.com

Documents mifandraika - CIMR-VU4A0011FAA

Preview YASKAWA AC Drive L1000A: Torolàlana fanombohana haingana ho an'ny fampiharana ascenseur
Ity Torolàlana Fanombohana Haingana ho an'ny Yaskawa AC Drive L1000A ity dia manome fampahalalana ilaina amin'ny fametrahana, tariby ary fametrahana voalohany ny AC drives ho an'ny fampiasana ascenseur. Izy io dia mirakitra fepetra fiarovana tena ilaina, fametrahana mekanika sy elektrika, fampiasana ny keypad ary fomba fanombohana.
Preview YASKAWA AC Drive A1000 Quick Start Guide
Quick Start Guide for the YASKAWA AC Drive A1000 series, a high-performance vector control drive. This manual provides essential information for safe installation, wiring, initial setup, operation, and troubleshooting of industrial AC drives.
Preview Boky Torolàlana momba ny Fifandraisana Modbus ho an'ny Yaskawa V7 sy V74X
Torolàlana ho an'ny fifandraisana Modbus ho an'ny kapila AC Yaskawa V7 sy V74X, izay mandrakotra ny fametrahana tambajotra (RS-232, RS-422, RS-485), ny fidirana amin'ny masontsivana, ny endriky ny hafatra, ary ny famahana olana ho an'ny automation indostrialy.
Preview Yaskawa AC Drive - Fanampiny rindrambaiko namboarina manokana A1000 High Frequency
Ity antontan-taratasy ity dia manampy ny Torolàlana Fanombohana Haingana sy ny Boky Torolàlana Teknika Yaskawa A1000, izay manazava amin'ny antsipiriany ny fanovana sy ny fiasa vaovao ho an'ny Rindrambaiko Ambony Matetika. Izy io dia mandrakotra ny fanovana ny masontsivana, ny fiasa ary ny fanamarihana fampiharana ho an'ny fampiharana motera haingam-pandeha.
Preview Yaskawa Z1000 AC Drive User Manual for HVAC Fan and Pump Applications
This comprehensive user manual provides detailed instructions for the Yaskawa Z1000 AC Drive, covering installation, setup, programming, operation, and troubleshooting for HVAC fan and pump applications. It includes specifications for 200V and 400V classes.
Preview Yaskawa V1000 mankany GA500 AC Drive Transition Guide
Torolàlana feno ho an'ny OEMs, integrators ary mpampiasa farany mamindra avy amin'ny Yaskawa V1000 series AC drives amin'ny Yaskawa GA500 AC drive. Ity antontan-taratasy ity dia mirakitra ny famantarana ny maodely, ny fisafidianana fiara, ny refy, ny tariby, ary ny fiarovana ny faritra sampana.