Sava lalana
This manual provides instructions for the installation, operation, and maintenance of the Altronix OLS120 Power Supply/Charger. The OLS120 is designed to provide regulated 12VDC or 24VDC power at 4 amps, with integrated AC and battery monitoring capabilities, utilizing a 115VAC input.
Torolàlana manan-danja momba ny fiarovana
- Installation and servicing should only be performed by qualified service personnel.
- To reduce the risk of electric shock, disconnect AC power before servicing.
- Hamarino tsara ny rivotra mba hisorohana ny hafanana be loatra.
- Aza atao amin'ny orana na hamandoana ilay fitaovana.
- Use only recommended battery types for backup power.
Vita ny vokatraview
The Altronix OLS120 is a robust power supply/charger unit engineered for reliable performance in various applications requiring stable DC power and battery backup.
Endri-javatra fototra
- Selectable 12VDC or 24VDC output.
- 4 amp continuous supply current.
- Integrated AC and battery monitoring.
- 115VAC input for power.
Famantarana singa

This image displays the Altronix OLS120 circuit board, highlighting various components essential for its operation. Familiarize yourself with these components before installation.
singa fototra:
- BOKYtage Fifantenana Selector: Located at the top right, labeled "OFF 24VDC ON 12VDC". This switch allows selection between 12VDC and 24VDC output.
- AC Input Terminals: Positioned at the bottom left, marked for 115VAC input connections.
- DC Output Terminals: Located at the bottom right, these terminals are for connecting devices that require 12VDC or 24VDC power.
- Toerana bateria: Found at the bottom right, near the PTCs, for connecting backup batteries.
- AC Fail Indicator (LED): An LED near the "AC FAL" label, which illuminates upon loss of AC power.
- Low Battery Indicator (LED): An LED near the "LOW BAT" label, indicating a low battery condition.
- mpanova: A central component, often labeled with part numbers like "P POL-30030", responsible for stepping down the AC voltage.
- Capacitors: Large cylindrical components (e.g., "C2", "C29A") used for filtering and energy storage.
- Fuses/PTCs: Overcurrent protection devices (e.g., "PTC1", "PTC2") to safeguard the circuit.
Fametrahana sy fametrahana
Dingana 1: Fametrahana
Securely mount the OLS120 in a suitable enclosure or location, ensuring adequate ventilation to prevent heat buildup.
Dingana 2: Voltage Fifidianana
Tadiavo ny voltage selector switch (labeled "OFF 24VDC ON 12VDC") on the circuit board. Set the switch to the desired output voltage (12VDC or 24VDC) before connecting any power.
Step 3: AC Power Connection
Connect the 115VAC input power to the designated AC input terminals. Ensure proper polarity and secure connections. Refer to local electrical codes for wiring practices.
Step 4: DC Output Connection
Connect your devices requiring DC power to the DC output terminals. Observe correct polarity to prevent damage to the connected equipment.
Step 5: Battery Connection (Optional)
For battery backup functionality, connect a suitable rechargeable battery to the battery terminals. Ensure correct polarity. The OLS120 will charge the battery and automatically switch to battery power upon AC failure.
hetsika
Powering On
Once all connections are secure and verified, apply 115VAC power to the unit. The unit will power on and begin providing regulated DC output.
Toetra famantarana
- AC Fail (LED): This indicator illuminates when the AC input power is lost, signaling that the unit is operating on battery backup (if connected).
- Low Bat (LED): This indicator illuminates when the connected battery voltage drops below a pre-set threshold, indicating that the battery requires charging or replacement.
fikarakarana
Fikarakarana ankapobeny
Keep the unit clean and free from dust accumulation. Ensure that all ventilation openings are not obstructed to maintain optimal operating temperature.
Fikojakojana ny bateria
If a backup battery is used, periodically check its condition and charge level. Replace the battery as recommended by the battery manufacturer or when its performance degrades.
Fanamboarana
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy misy Output DC | Tsy misy herinaratra miditra AC | Check AC power source and connections. |
| Tsy misy Output DC | Diso voltage fifantenana | Hamarino voltage selector switch is set correctly (12VDC or 24VDC). |
| AC Fail LED On | Loss of AC power | Restore AC power. |
| Low Bat LED On | Batterie nesorina na diso | Check battery charge and condition; replace if necessary. |
| Output miato | Fifandraisana malalaka | Secure all wiring connections. |
For issues not listed above, or if troubleshooting steps do not resolve the problem, please contact Altronix technical support for further assistance.
fepetra arahana
- Haben'ny vokatra: 8.4 x 5.7 x 2.9 santimetatra
- Lanja entana: 1.2 kg
- Output Voltage: 12VDC or 24VDC (selectable)
- Output ankehitriny: 4 amp
- Fampidirana Voltage: 115VAC
- Mpanamboatra: ALTRONIX
- Laharana modely: Sary OLS120D2X
- Daty misy voalohany: 31 Jolay 2010
Warranty sy fanohanana ara-teknika
Altronix products are backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the official Altronix webtranonkala na ny antontan-taratasy miaraka amin'ny fividiananao.
For technical assistance, product inquiries, or support, please contact Altronix customer service directly. Contact information can typically be found on the manufacturer's website.
Manufacturer: Altronix Corp.