Altronix OLS120

Boky Torolàlana ho an'ny Mpampiasa ny Famatsiana Herinaratra/Famandrihana Altronix OLS120

Model: OLS120

Sava lalana

This manual provides instructions for the installation, operation, and maintenance of the Altronix OLS120 Power Supply/Charger. The OLS120 is designed to provide regulated 12VDC or 24VDC power at 4 amps, with integrated AC and battery monitoring capabilities, utilizing a 115VAC input.

Torolàlana manan-danja momba ny fiarovana

  • Installation and servicing should only be performed by qualified service personnel.
  • To reduce the risk of electric shock, disconnect AC power before servicing.
  • Hamarino tsara ny rivotra mba hisorohana ny hafanana be loatra.
  • Aza atao amin'ny orana na hamandoana ilay fitaovana.
  • Use only recommended battery types for backup power.

Vita ny vokatraview

The Altronix OLS120 is a robust power supply/charger unit engineered for reliable performance in various applications requiring stable DC power and battery backup.

Endri-javatra fototra

  • Selectable 12VDC or 24VDC output.
  • 4 amp continuous supply current.
  • Integrated AC and battery monitoring.
  • 115VAC input for power.

Famantarana singa

Altronix OLS120 Power Supply/Charger circuit board

This image displays the Altronix OLS120 circuit board, highlighting various components essential for its operation. Familiarize yourself with these components before installation.

singa fototra:

  • BOKYtage Fifantenana Selector: Located at the top right, labeled "OFF 24VDC ON 12VDC". This switch allows selection between 12VDC and 24VDC output.
  • AC Input Terminals: Positioned at the bottom left, marked for 115VAC input connections.
  • DC Output Terminals: Located at the bottom right, these terminals are for connecting devices that require 12VDC or 24VDC power.
  • Toerana bateria: Found at the bottom right, near the PTCs, for connecting backup batteries.
  • AC Fail Indicator (LED): An LED near the "AC FAL" label, which illuminates upon loss of AC power.
  • Low Battery Indicator (LED): An LED near the "LOW BAT" label, indicating a low battery condition.
  • mpanova: A central component, often labeled with part numbers like "P POL-30030", responsible for stepping down the AC voltage.
  • Capacitors: Large cylindrical components (e.g., "C2", "C29A") used for filtering and energy storage.
  • Fuses/PTCs: Overcurrent protection devices (e.g., "PTC1", "PTC2") to safeguard the circuit.

Fametrahana sy fametrahana

Dingana 1: Fametrahana

Securely mount the OLS120 in a suitable enclosure or location, ensuring adequate ventilation to prevent heat buildup.

Dingana 2: Voltage Fifidianana

Tadiavo ny voltage selector switch (labeled "OFF 24VDC ON 12VDC") on the circuit board. Set the switch to the desired output voltage (12VDC or 24VDC) before connecting any power.

Step 3: AC Power Connection

Connect the 115VAC input power to the designated AC input terminals. Ensure proper polarity and secure connections. Refer to local electrical codes for wiring practices.

Step 4: DC Output Connection

Connect your devices requiring DC power to the DC output terminals. Observe correct polarity to prevent damage to the connected equipment.

Step 5: Battery Connection (Optional)

For battery backup functionality, connect a suitable rechargeable battery to the battery terminals. Ensure correct polarity. The OLS120 will charge the battery and automatically switch to battery power upon AC failure.

hetsika

Powering On

Once all connections are secure and verified, apply 115VAC power to the unit. The unit will power on and begin providing regulated DC output.

Toetra famantarana

  • AC Fail (LED): This indicator illuminates when the AC input power is lost, signaling that the unit is operating on battery backup (if connected).
  • Low Bat (LED): This indicator illuminates when the connected battery voltage drops below a pre-set threshold, indicating that the battery requires charging or replacement.

fikarakarana

Fikarakarana ankapobeny

Keep the unit clean and free from dust accumulation. Ensure that all ventilation openings are not obstructed to maintain optimal operating temperature.

Fikojakojana ny bateria

If a backup battery is used, periodically check its condition and charge level. Replace the battery as recommended by the battery manufacturer or when its performance degrades.

Fanamboarana

OLANAAntony mety hitrangavahaolana
Tsy misy Output DCTsy misy herinaratra miditra ACCheck AC power source and connections.
Tsy misy Output DCDiso voltage fifantenanaHamarino voltage selector switch is set correctly (12VDC or 24VDC).
AC Fail LED OnLoss of AC powerRestore AC power.
Low Bat LED OnBatterie nesorina na disoCheck battery charge and condition; replace if necessary.
Output miatoFifandraisana malalakaSecure all wiring connections.

For issues not listed above, or if troubleshooting steps do not resolve the problem, please contact Altronix technical support for further assistance.

fepetra arahana

  • Haben'ny vokatra: 8.4 x 5.7 x 2.9 santimetatra
  • Lanja entana: 1.2 kg
  • Output Voltage: 12VDC or 24VDC (selectable)
  • Output ankehitriny: 4 amp
  • Fampidirana Voltage: 115VAC
  • Mpanamboatra: ALTRONIX
  • Laharana modely: Sary OLS120D2X
  • Daty misy voalohany: 31 Jolay 2010

Warranty sy fanohanana ara-teknika

Altronix products are backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the official Altronix webtranonkala na ny antontan-taratasy miaraka amin'ny fividiananao.

For technical assistance, product inquiries, or support, please contact Altronix customer service directly. Contact information can typically be found on the manufacturer's website.

Manufacturer: Altronix Corp.

Documents mifandraika - OLS120

Preview Altronix OLS120 Torolàlana Fametrahana Charger Famatsiana herinaratra | Famaritana ara-teknika
Torolàlana fametrahana amin'ny antsipiriany sy ny fepetra ara-teknika ho an'ny Altronix OLS120 Off-Line Power Supply / Charger, mandrakotra nyview, fampidirana/famoahana, backup bateria, fanaraha-maso, ary famantarana ny terminal.
Preview Altronix R1224DC16CBV Rack Mount Torolàlana fametrahana famatsiana herinaratra
Torolàlana fametrahana ny famatsiana herinaratra Altronix R1224DC16CBV Rack Mount, izay manazava amin'ny antsipiriany ny mombamomba azy, ny endri-javatra ary ny dingana fametrahana tsikelikely ho an'ny fametrahana ny rack na talantalana. Manome output 12VDC na 24VDC miaraka amin'ny output voaaro PTC 16.
Preview Altronix OLS75 Off-Line Famatsiana herinaratra/Fametrahana Charger Guide
Torolàlana fametrahana ny Altronix OLS75 Off-Line Power Supply/Charger, izay manome antsipiriany momba ny famaritana, ny endri-javatra ary ny torolàlana fametrahana ho an'ny output azo safidiana 12VDC/24VDC miaraka amin'ny courant mitohy 2.5A.
Preview Altronix DPS5: Torolàlana fametrahana famatsiana herinaratra sy charger 6/12/24VDC azo ampiasaina amin'ny zavatra maro
Ity torolàlana ity dia manome torolàlana momba ny fametrahana sy ny famaritana ny Altronix DPS5, izay famatsiana herinaratra sy famandrihana azo ampiasaina amin'ny fomba maro samihafa, izay manolotra output 6VDC, 12VDC, na 24VDC azo safidiana amin'ny 4A. Mety tsara amin'ny fanaraha-maso ny fidirana, ny fiarovana ary ny rafitra CCTV.
Preview Altronix AL125ULB Two Output Switching Power Supply/Charger Datasheet
Famaritana ara-teknika sy mihoatraview for the Altronix AL125ULB, a two-output switching power supply and charger with PTC protected 12VDC/24VDC outputs, battery backup, and supervision features.
Preview Altronix AL400ULB UL Recognized Power Supply/Charger - Specifications and Installation
Detailed specifications, installation guide, and maintenance information for the Altronix AL400ULB UL Recognized power supply and charger, featuring 12VDC/24VDC selectable output and battery backup.