Extech 382252

Extech 382252 Earth Ground Resistance Tester Kit User Manual

1. Fampidirana

The Extech 382252 is a comprehensive Earth Ground Resistance Tester Kit designed for accurate measurement of earth ground resistance. This kit provides three selectable ranges for earth ground resistance: 20 Ohms (Ω), 200 Ohms (Ω), and 2000 Ohms (Ω). Beyond earth ground testing, the device also functions as a multimeter, capable of measuring AC/DC Voltage, Resistance, and Continuity. It features automatic zero adjustment for ease of use. This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your Extech 382252.

2. Information momba ny fiarovana

fampitandremana: Improper use of this meter can cause damage, shock, injury, or death. Read and understand all safety information and operating instructions before using this instrument. Always adhere to local and national safety codes.

  • Aza mihoatra ny fetra ambony indrindra azo ampidirina ho an'ny asa rehetra.
  • Exercise extreme caution when working with live electrical circuits.
  • Ensure the meter is in good working condition and free from damage before use.
  • Ampiasao foana ny fiasa sy ny elanelana mety amin'ny fandrefesana.
  • Soloy ny bateria rehefa miseho ny famantarana ny bateria ambany mba hahazoana antoka fa marina ny famakiana.
  • Keep hands and fingers away from test probe tips when making measurements.
  • Do not operate the meter in explosive atmospheres or in the presence of flammable gases or dust.

3. Ny votoatin'ny fonosana

Hamarino fa misy sy tsy simba ny entana rehetra rehefa novoahana:

  • Extech 382252 Earth Ground Resistance Tester
  • Test Leads (set)
  • Auxiliary Earth Bars (2 pieces)
  • Carrying Case
  • Protective Rubber Holster
  • 1.5V AA Batteries (6 pieces)
Extech 382252 Earth Ground Resistance Tester Kit Contents

Image 1: The Extech 382252 Earth Ground Resistance Tester Kit, showing the main unit, test leads, two auxiliary earth bars, and the carrying case.

4. Toetran'ny vokatra

The Extech 382252 offers the following key features:

  • Earth Ground Resistance measurement in three ranges: 20Ω, 200Ω, and 2000Ω.
  • AC / DC Voltage measurement capabilities.
  • Resistance and Continuity testing functions.
  • Automatic zero adjustment for accurate readings.
  • Fampisehoana LCD lehibe sy mora vakiana.
  • Data Hold function to freeze displayed readings.
  • Backlight for visibility in low-light conditions.
  • Durable protective rubber holster.
Extech 382252 Earth Ground Resistance Tester Front View

Sary 2: Eo anoloana view of the Extech 382252 Earth Ground Resistance Tester, highlighting its display, function dial, and control buttons.

5. Fametrahana

5.1 Fametrahana bateria

  1. Ataovy azo antoka fa maty ny herinaratra ao amin'ny metatra.
  2. Tadiavo ny fonon'ny fitoeran'ny bateria eo amin'ny faran'ny metatra.
  3. Use a screwdriver to remove the screw(s) securing the cover.
  4. Insert six (6) 1.5V AA batteries, observing correct polarity (+/-).
  5. Avereno apetraka ny fonon'ny fitoeran'ny bateria ary hamafiso amin'ny visy.

5.2 Fampifandraisana ireo mpitarika fitsapana

Connect the test leads to the appropriate input jacks on the meter for the desired measurement function. For earth ground resistance testing, specific connections involving the auxiliary earth bars will be detailed in the operating instructions.

6. Torolàlana miasa

6.1 Power On/off

Rotate the function dial from the 'OFF' position to any desired measurement function to power on the meter. To power off, rotate the dial back to the 'OFF' position.

6.2 Automatic Zero Adjustment

The meter features automatic zero adjustment. When selecting a resistance range, the meter will automatically adjust to zero, compensating for lead resistance. Ensure test leads are not shorted or open during this process for accurate zeroing.

6.3 Fihazonana angon-drakitra

Press the 'HOLD' button to freeze the current reading on the display. Press it again to release the hold and resume live readings.

6.4 Asa jiro miverina

Press the backlight button (often indicated by a light bulb icon) to illuminate the display for better visibility in dark environments. Press it again to turn off the backlight.

7. Earth Ground Resistance Measurement

The Extech 382252 uses the 3-wire (or Fall-of-Potential) method for earth ground resistance measurements. This method requires the use of the two auxiliary earth bars provided.

7.1 Measurement Procedure (3-Wire Method)

  1. Fiomanana: Ensure the circuit under test is de-energized and safely isolated.
  2. Placement of Auxiliary Earth Bars:
    • Drive the first auxiliary earth bar (P) into the ground at a suitable distance from the earth electrode (E) being tested.
    • Drive the second auxiliary earth bar (C) into the ground at a further distance from P, ensuring all three points (E, P, C) are in a straight line. Typical distances are 5-10 meters (15-30 feet) between E and P, and P and C, but may vary based on soil conditions and electrode size.
  3. Fampifandraisana ireo Tariby Fitsapana:
    • Connect the 'E' terminal of the meter to the earth electrode under test.
    • Connect the 'P' terminal of the meter to the first auxiliary earth bar (P).
    • Connect the 'C' terminal of the meter to the second auxiliary earth bar (C).
  4. Safidio ny Range: Rotate the function dial to the desired Earth Ground Resistance range (20Ω, 200Ω, or 2000Ω). Start with the highest range if the resistance value is unknown.
  5. Perform Test: Press the 'TEST' button. The meter will inject a current and measure the voltage drop to calculate the earth ground resistance.
  6. Mamaky fandrefesana: The resistance value will be displayed on the LCD.
  7. Hamarino ny fahamarinany: For critical measurements, it is recommended to repeat the test with the auxiliary earth bars placed at slightly different distances to ensure the reading is stable and accurate.

8. Other Measurements

8.1 AC/DC Voltage Fandrefesana

  1. Connect the red test lead to the 'V' input jack and the black test lead to the 'COM' input jack.
  2. Rotate the function dial to the desired ACV (750V AC) or DCV (1000V DC) range.
  3. Ampifandraiso manerana ny faritra na ny singa izay horefesina ireo probe fitsapana.
  4. Vakio ny voltage sanda eo amin'ny efijery.

8.2 Fandrefesana fanoherana

  1. Ataovy azo antoka fa tsy misy herinaratra ao amin'ny faritra na ny singa.
  2. Connect the red test lead to the 'V' input jack and the black test lead to the 'COM' input jack.
  3. Rotate the function dial to the desired Resistance range (e.g., 200Ω, 20kΩ, 200kΩ).
  4. Ampifandraiso manerana ny singa ireo fitaovana fitsapana.
  5. Vakio ny sandan'ny fanoherana eo amin'ny fampisehoana.

8.3 Fitsapana mitohy

  1. Ataovy azo antoka fa tsy misy herinaratra ao amin'ny faritra na ny singa.
  2. Connect the red test lead to the 'V' input jack and the black test lead to the 'COM' input jack.
  3. Rotate the function dial to the Continuity position (often indicated by a speaker icon).
  4. Connect the test probes across the component or wire.
  5. An audible beep indicates continuity (low resistance). The display will show the resistance value.

9. Fikojakojana

9.1 Fanadiovana

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Periodically clean the test leads and probes to ensure good electrical contact.

9.2 Fanoloana bateria

When the low battery indicator appears on the display, replace the batteries promptly to maintain measurement accuracy. Refer to Section 5.1 for battery installation instructions.

9.3 Fitehirizana

If the meter is to be stored for an extended period, remove the batteries to prevent leakage and damage. Store the meter in its carrying case in a cool, dry environment, away from direct sunlight and extreme temperatures.

10. Famahana olana

  • No Display/Meter Not Powering On: Check battery installation and ensure batteries are fresh. Verify the function dial is not in the 'OFF' position.
  • Famakiana tsy marina: Ensure test leads are properly connected and not damaged. Check battery level. For earth ground resistance, verify proper placement and connection of auxiliary earth bars and ensure good contact with the ground.
  • Tsisy fitohizana bip: Check if the circuit is truly continuous. Ensure test leads are making good contact.
  • Display Shows 'OL' (Overload): Mihoatra ny elanelana voafantina ny sanda voarefy. Mifindra amin'ny elanelana ambony kokoa.

If issues persist after following these steps, contact customer support.

11. Famaritana

famaritanasarobidy
MarikaExtech
Laharana modely382252
Earth Ground Resistance Ranges20Ω, 200Ω, 2000Ω
AC Voltage RangeHatramin'ny 750V AC
DC Voltage RangeHatramin'ny 1000V DC
Ranges fanoherana20Ω, 200Ω, 20kΩ, 200kΩ (typical, check device for full ranges)
Fahamarinana fandrefesana+/-0.5% (for certain functions, refer to product manual for specifics)
Loharanon-kery6 x 1.5V AA Batterie
Lanja entana0.69 kilao (1.52 kilao)
Haben'ny vokatra (L x W x H)7.9 x 3.6 x 2 santimetatra
Anisan'ny singaTest leads, 2 earth bars, carrying case, holster, six 1.5V AA batteries
Naoty fiarovanaCAT III 1000V, CE

12. Garantie

The Extech 382252 Earth Ground Resistance Tester Kit typically comes with a Garantie voafetra 1 taona from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, accident, unauthorized repair, or modification. Please retain your proof of purchase for warranty claims.

13. Fanohanana

For technical assistance, calibration services, or further information regarding your Extech 382252, please refer to the official Extech website or contact their customer support department. Contact details can usually be found on the manufacturer's webtranokala na ao amin'ny antontan-taratasy miaraka amin'ny vokatrao.

Documents mifandraika - 382252

Preview Boky Torolàlana ho an'ny Mpampiasa ny Extech ET40 Heavy Duty Continuity Tester
Boky torolalana ho an'ny mpampiasa ny Extech ET40 Heavy Duty Continuity Tester. Mianara ny fomba fitsapana azo antoka sy mahomby ny fitohizan'ny singa tsy misy herinaratra, fuses, switches, relays, tariby ary circuit boards.
Preview Extech CT20 Continuity Tester Pro User Manual - Features, Specifications, and Operation
Comprehensive user manual for the Extech CT20 Continuity Tester Pro. Learn about its features, specifications, safety precautions, local continuity testing, and advanced remote continuity and wire identification capabilities.
Preview Tondro roa sosona Extech ET20 Voltage Boky torolalana ho an'ny mpampiasa mpitsikilo
Boky torolalana ho an'ny mpampiasa ny Extech ET20 Dual Indicator Vol.tage Detector, Volo AC/DC 2-LalanatagMpandrefy e (100-250V). Manome fampahalalana momba ny fampiasana, ny antoka ary ny serivisy.
Preview Torolàlana ho an'ny mpampiasa Extech EX650 Series: 600A True RMS Digital Clamp metatra
Torolàlana feno ho an'ny mpampiasa ny andiany Extech EX650 an'ny fakantsary nomerika 600A True RMSamp metatra, mandrakotra ny modely EX650 sy EX655. Mianara momba ny fampiasana, ny endri-javatra, ny fiarovana ary ny fepetra takiana ho an'ny volta AC/DC marinatage, courant, resistance, ary fandrefesana maro hafa.
Preview Extech DV30 AC Voltage Boky torolalana ho an'ny mpampiasa mpitsikilo
Boky torolalana ho an'ny mpampiasa ny Extech DV30 AC VoltagDetector e, izay manome antsipiriany momba ny fepetra fiarovana, ny fampiasana azy, ny famaritana azy, ny fanoloana bateria, ny fanariana azy, ny antoka ary ny fampahalalana momba ny fifandraisana.
Preview Extech UM200 Micro-Ohmmeter User Manual - Features and Specifications
User manual for the Extech UM200 Micro-Ohmmeter, detailing its features, operation, specifications, and maintenance. Ideal for measuring low resistances in various materials.