Johnson Controls T-3300-1

Boky Torolalana ho an'ny Thermostat Pneumatic Johnson Controls T-3300-1

Model: T-3300-1

1. Fampidirana

This manual provides essential information for the installation, setup, operation, and maintenance of the Johnson Controls T-3300-1 Pneumatic Thermostat. This device is designed to maintain space comfort by controlling the temperature of air returning to a terminal air conditioning unit. It supports both Direct Acting (DA) and Reverse Acting (RA) configurations, operating within a temperature range of 60 to 150 degrees Fahrenheit.

Azafady vakio tsara ity boky torolalana ity alohan'ny hametrahana sy hampiasana azy mba hahazoana antoka fa miasa tsara sy azo antoka tsara.

2. Information momba ny fiarovana

FAMPITANDREMANA: Installation and servicing must be performed by qualified personnel only. Failure to follow these instructions could result in personal injury or equipment damage.

3. Vokatra singa

The Johnson Controls T-3300-1 Pneumatic Thermostat consists of the main control unit, a temperature sensing bulb with capillary tubing, and mounting hardware.

Johnson Controls T-3300-1 Pneumatic Thermostat with sensing bulb and mounting bracket

Sary 1: TAPITRAview of the Johnson Controls T-3300-1 Pneumatic Thermostat. The image displays the olive-green main control unit with a silver adjustment dial labeled 'COOL' to 'WARM'. Two brass pneumatic connections are visible on the top and left side. A coiled copper capillary tube extends from the unit, terminating in a copper temperature sensing bulb. Below the main unit is a silver mounting bracket and a separate silver lever with a black rubber grommet, likely for calibration or linkage.

4. Fametrahana

4.1 Fametrahana ny Thermostat

  1. Select a suitable mounting location that accurately reflects the space temperature and is free from drafts, direct sunlight, or heat sources.
  2. Secure the mounting bracket to the wall or panel using appropriate fasteners.
  3. Attach the main control unit to the mounting bracket.

4.2 Connecting Pneumatic Lines

  1. Connect the main air supply line (typically 15 PSIG for Direct Acting or 20 PSIG for Reverse Acting) to the designated supply port.
  2. Connect the control line to the appropriate output port, leading to the controlled device (e.g., damper actuator, valve).
  3. Ensure all pneumatic connections are tight to prevent air leaks.

4.3 Positioning the Sensing Bulb

Position the temperature sensing bulb in the return air stream or the area where temperature control is desired. Ensure the bulb is not obstructed and can accurately sense the air temperature.

5. Fametrahana sy calibration

5.1 Fampivoarana voalohany

Once installation is complete, restore the pneumatic air supply. The thermostat will begin to respond to temperature changes.

5.2 Fametrahana ny mari-pana irina

Rotate the adjustment dial on the front of the thermostat to set the desired temperature. Turn towards 'COOL' for lower temperatures or 'WARM' for higher temperatures. The specific temperature scale may vary based on calibration.

5.3 Calibration (If Required)

If precise temperature control is critical, or if the thermostat's reading appears inaccurate, professional calibration may be necessary. Refer to the detailed service manual or contact a qualified HVAC technician for calibration procedures. This typically involves adjusting internal mechanisms to match a known reference temperature.

6. Fampandehanana

The T-3300-1 thermostat operates by sensing the air temperature via its capillary tube and bulb. Based on the setpoint and the sensed temperature, it modulates the pneumatic output pressure to control a connected device, thereby maintaining the desired space comfort.

The thermostat continuously adjusts its output to counteract temperature deviations from the setpoint.

7. Fikojakojana

The Johnson Controls T-3300-1 is designed for reliable operation with minimal maintenance. However, periodic checks can ensure optimal performance.

8. Famahana olana

This section addresses common issues you might encounter with your T-3300-1 thermostat.

OLANAAntony mety hitrangavahaolana
Thermostat tsy mamaly ny fiovan'ny mari-pana.No pneumatic air supply; Leaking connections; Damaged sensing bulb/capillary.Verify air supply; Check and tighten connections; Inspect sensing bulb for damage (replace if necessary).
Fifehezana ny mari-pana tsy marina.Improper calibration; Sensing bulb improperly located; Drafts or heat sources affecting bulb.Recalibrate by qualified personnel; Relocate sensing bulb; Shield bulb from external influences.
Constant air leak from thermostat.Loose pneumatic fittings; Internal diaphragm or valve issue.Tighten fittings; Contact qualified technician for internal repair or replacement.

For issues not listed here or if troubleshooting steps do not resolve the problem, contact Johnson Controls technical support or a certified HVAC professional.

9. Famaritana

endri-javatraantsipirihany
Laharana modelyT-3300-1
Karazana vokatraPneumatic Thermostat
Laharana miasa60 hatramin'ny 150 degre Fahrenheit
ActionDirect Acting (DA) / Reverse Acting (RA)
Direct Acting Supply Pressure15 PSI
Reverse Acting Supply Pressure20 PSI
refy (L x W x H)7.0" x 7.0" x 5.0" (Approximate package dimensions, actual unit may vary slightly)
lanja3 kilao (eo ho eo)
lokoMaitso
Karazana ControllerPush Button (Refers to adjustment dial)
Endri-javatra manokanaAuto Changeover (Functionality)

10. Warranty sy fanohanana

For warranty information, technical support, or service inquiries, please refer to the official Johnson Controls website or contact their customer service department. Keep your purchase receipt and model number (T-3300-1) handy when contacting support.

Johnson Controls is committed to providing high-quality products and support.

Documents mifandraika - T-3300-1

Preview Hx 3 Touch Screen Thermostat User Information Manual
Ity boky torolalana momba ny mpampiasa ity dia manome torolalana sy torolalana amin'ny antsipiriany momba ny Thermostat Screen Touch Johnson Controls Hx 3 (Modely: S1-THXU430W), mirakitra ny fametrahana, ny endri-javatra, ny fampandehanana, ny fampifandraisana ny fampiharana ary ny fandrindrana.
Preview Torolalana fanombohana haingana ho an'ny Thermostats amin'ny Fan Coil On/Off na Floating Series TEC3000
This Quick Start Guide provides essential information for installing, configuring, and troubleshooting the Johnson Controls TEC3000 Series On/Off or Floating Fan Coil Thermostats. It covers emissions compliance, installation steps, wiring diagrams, setup procedures, and technical specifications.
Preview Johnson Controls FCP Largo Thermostat User Guide: FCP-NA-701-L & FCP-PA-701-L
Comprehensive user guide for Johnson Controls FCP-NA-701-L and FCP-PA-701-L Largo thermostats. Covers features, installation, configuration, operation, advanced settings, troubleshooting, and technical specifications for fan coil and PTAC systems.
Preview Smart Equipment Controls (SEC) Torolàlana fanombohana haingana ho an'ny mpanara-maso ny tarika
Ity torolàlana fanombohana haingana ity dia manome torolalana tena ilaina amin'ny fanamafisana ny fanaraha-maso ny tarika Johnson Controls Smart Equipment Controls (SEC), mandrakotra ny fananganana voalohany, ny fitetezana LCD, ny menus fampandehanana, ary ny fomba fiasa backup ny rafitra ho an'ny modely toa ny SE-SPU1001-1 sy SE-ECO1001-1.
Preview TEC3000 Series Wireless Economizer Thermostat Controllers: Installation Guide
Comprehensive installation instructions for the Johnson Controls TEC3000 Series Wireless Single- or Two-Stage Economizer Thermostat Controllers, covering applications, location, wiring, setup, adjustments, and troubleshooting.
Preview Johnson Controls EP-8000 Series Electro-Pneumatic Transducers: Technical Specifications, Installation, and Operation
Detailed technical bulletin for Johnson Controls EP-8000 Series Electro-Pneumatic Transducers. Covers product overview, operation, dimensions, installation, wiring, calibration, and technical specifications for industrial control applications.