1. Fampidirana
This manual provides instructions for the safe and effective use of the Sealey MM19 Digital Multimeter. The MM19 is a general-purpose multimeter designed for measuring various electrical parameters, including AC and DC voltage, DC current, resistance, audible continuity, and diode/transistor verification. Please read this manual thoroughly before operation and retain it for future reference.
2. Information momba ny fiarovana
Always observe basic safety precautions when using electrical test equipment to reduce the risk of fire, electric shock, or personal injury. This device complies with IEC 1010 and CE CAT II safety standards.
- Do not exceed the maximum input limits for any function. Refer to the specifications section for details.
- Aza mihatra mihitsy voltage to the meter when the rotary switch is set to Resistance (Ω), Diode, Continuity, or Current (A) functions.
- Mitandrema rehefa miasa amin'ny voltages above 30V AC RMS, 42V peak, or 60V DC. Ireo voltagmiteraka loza mitatao.
- Ensure the test leads are in good condition, without cracked or broken insulation.
- Always connect the common (COM) test lead first and disconnect it last.
- Disconnect power to the circuit under test before measuring resistance or continuity.
- Soloy avy hatrany ny bateria when the low battery indicator appears to ensure accurate readings.
3. Vokatra mihoatraview
The Sealey MM19 Digital Multimeter features a clear LCD display, a central rotary switch for function selection, and input jacks for test leads.

The Sealey MM19 Digital Multimeter, shown with its yellow casing, large LCD display, rotary function switch, and red and black test leads connected to the input jacks.
singa:
- LCD Display: Large (46 x 25mm) digital display for reading measurements.
- Rotary Switch: Ampiasaina hisafidianana ny fiasa sy ny elanelana fandrefesana tianao.
- VΩmA Input Jack: Ho an'ny voltage, ny fanoherana, ary ny fandrefesana ny courant hatramin'ny 200mA.
- 10ADC Input Jack: For high current measurements up to 10A DC (unfused).
- COM Input Jack: Fidirana iraisana (ratsy) ho an'ny fandrefesana rehetra.
- Sokety hFE: For transistor (NPN/PNP) testing.
- Fitarihana fitsapana: Red (positive) and Black (negative) leads for connecting to circuits.
4. Fametrahana
4.1. Fametrahana bateria
The Sealey MM19 Multimeter requires a 9V battery for operation. If the display does not illuminate or shows a low battery indicator, the battery needs to be installed or replaced.
- Ataovy azo antoka fa maty ny multimeter.
- Tadiavo ny fonon'ny efitrefitra bateria ao ambadiky ny fitaovana.
- Esory ny visy mihazona ny fonony ary esory moramora.
- Connect a new 9V battery to the battery clips, observing correct polarity.
- Place the battery inside the compartment and replace the cover, securing it with the screw(s).
4.2. Fampifandraisana ireo Tariby Fitsapana
The multimeter is supplied with a pair of test leads (red and black).
- Ampidiro ny black test lead ao amin'ny fr Jack fidirana (mahazatra).
- Ho an'ny ankamaroan'ny fandrefesana (voltage, resistance, low current), insert the red test lead ao amin'ny VΩmA fampidirana jack.
- For high DC current measurements (up to 10A), insert the red test lead ao amin'ny 10ADC fampidirana jack.
5. Torolàlana miasa
To operate the multimeter, select the desired function and range using the rotary switch.
5.1. Fandrefesana ny Volan'ny DCtage (DCV)
- Insert the red lead into the VΩmA jack and the black lead into the COM jack.
- Set the rotary switch to the desired DCV range (e.g., 200m, 2000m, 20, 200, 1000). Start with the highest range if the voltage tsy fantatra.
- Ampifandraiso amin'ilay singa na faritra horefesina ireo tariby fitsapana.
- Vakio ny voltage sanda eo amin'ny efijery LCD.
5.2. Fandrefesana AC Voltage (ACV)
- Insert the red lead into the VΩmA jack and the black lead into the COM jack.
- Set the rotary switch to the desired ACV range (e.g., 200, 750). Start with the highest range if the voltage tsy fantatra.
- Ampifandraiso amin'ilay singa na faritra horefesina ireo tariby fitsapana.
- Vakio ny voltage sanda eo amin'ny efijery LCD.
5.3. Measuring DC Current (DCA)
- For currents up to 200mA: Insert the red lead into the VΩmA jack and the black lead into the COM jack.
- For currents up to 10A: Insert the red lead into the 10ADC jack and the black lead into the COM jack.
- Set the rotary switch to the desired DCA range (e.g., 200μ, 2000μ, 20m, 200m, 10A). Start with the highest range if the current is unknown.
- Vonoy ny herinaratra mankany amin'ny circuit. Open the circuit where the current is to be measured.
- Ampifandraiso amin'ny circuit ny multimeter amin'ny alalan'ny "series".
- Ampidiro ny herinaratra amin'ny faritra ary vakio ny sandan'ny herinaratra amin'izao fotoana izao eo amin'ny efijery LCD.
5.4. Fandrefesana ny fanoherana (Ω)
- Insert the red lead into the VΩmA jack and the black lead into the COM jack.
- Set the rotary switch to the desired Resistance (Ω) range (e.g., 200, 2000, 20k, 200k, 2000k).
- Ensure the circuit under test is de-energized.
- Ampifandraiso amin'ilay singa horefesina ireo tariby fitsapana.
- Vakio ny sandan'ny fanoherana eo amin'ny efijery LCD.
5.5. Audible Continuity Test
- Insert the red lead into the VΩmA jack and the black lead into the COM jack.
- Set the rotary switch to the continuity symbol (speaker icon).
- Ensure the circuit under test is de-energized.
- Ampifandraiso amin'ny singa na tariby ireo taribin'ny fitsapana.
- If continuity exists (low resistance), the meter will emit an audible tone. The display will show the resistance value.
5.6. Diode/Transistor Verification Mode (hFE)
- Insert the red lead into the VΩmA jack and the black lead into the COM jack for diode testing.
- Set the rotary switch to the diode symbol.
- Ampifandraiso amin'ny anode ny tariby mena ary amin'ny cathode an'ny diode ny tariby mainty. Hampiseho ny voltase mandroso ny fampisehoana.tage drop. Reverse the leads; the display should show 'OL' (open loop) for a good diode.
- For transistor hFE measurement, insert the transistor leads (Emitter, Base, Collector) into the appropriate sockets (E, B, C) in the hFE test socket, ensuring correct NPN or PNP type selection.
- Read the hFE value on the LCD display.
6. Fikojakojana
6.1. Fanadiovana
Fafao ny metatra casing sy adamp lamba sy savony malefaka. Aza mampiasa akora manimba na ranoka solvent. Ataovy azo antoka fa maina tanteraka ny metatra alohan'ny hampiasana azy.
6.2. Fanoloana bateria
Refer to Section 4.1 for battery installation instructions. Replace the 9V battery when the low battery indicator appears on the display to maintain measurement accuracy.
7. Famahana olana
- Tsy misy fampisehoana: Jereo ny fametrahana ny batterie ary ataovy azo antoka fa ampy ny fiampangana ny batterie.
- 'OL' or '1' on Display: This usually indicates an over-range condition or an open circuit. Select a higher range or check connections.
- Famakiana diso: Ensure the correct function and range are selected. Check test lead connections and battery condition.
- No Continuity Tone: Verify the circuit is de-energized and the leads are making good contact.
8. Famaritana
| fikirana | sarobidy |
|---|---|
| Marika | Sealey |
| Laharana modely | MM19 |
| Loharanon-kery | Batterie (9V) |
| miseho | Digital LCD (46 x 25mm) |
| DC Voltage (DCV) | 200mV, 2000mV, 20V, 200V, 1000V |
| AC Voltage (ACV) | 200V, 750V |
| DC Current (DCA) | 200µA, 2000µA, 20mA, 200mA, 10A |
| Fanoherana (Ω) | 200Ω, 2000Ω, 20kΩ, 200kΩ, 2000kΩ |
| fanohizana | Audible tone below approx. 30Ω |
| Test diode | Mandrosoa voltage drop display |
| Transistor Test | hFE (NPN/PNP) |
| Naoty fiarovana | CE CAT II, IEC 1010 |
| refy (L x W x H) | 1.93 x 4.21 x 6.06 santimetatra |
| Lanja entana | 9.5 ounces (0.27 kilao) |
9. Warranty sy fanohanana