1. Fampidirana
The AT1-4000X Variable Frequency Drive (VFD) is designed to provide precise speed control for 3-phase 4kW AC motors, operating from a single-phase 220V AC input. This VFD utilizes a unique control method to achieve high torque, high accuracy, and a wide speed regulating range, ensuring high performance in various applications.
Ny endri-javatra fototra dia ahitana:
- Excellent anti-trip performance and adaptability to challenging power conditions, temperature fluctuations, humidity, and dust interference, significantly enhancing stability.
- Optimized PWM control technology and electromagnetic compatibility for low noise and reduced electromagnetic interference.
- User-friendly design for easy operation and wiring.
- Fast start and stop response with substantial torque at low speeds.
2. Fiarovana fiarovana
Failure to follow these instructions may result in death, serious injury, or significant property loss.
- Always ensure the power supply is disconnected before performing any wiring or maintenance.
- Never connect the U/V/W output terminals to the AC power supply. Doing so will cause severe damage to the inverter.
- Do not install the inverter in environments with flammable or explosive gases, as this poses a risk of explosion.
- The ground terminal (GND) of the inverter must be properly and securely grounded.
- Only qualified professionals should perform internal wiring or open the inverter's casing due to the presence of high voltage.

3. Vokatra mihoatraview
The AT1-4000X VFD features a clear digital display and an intuitive control panel for easy monitoring and adjustment of motor parameters. The unit is designed for efficient heat dissipation with integrated cooling fins and fans.
3.1 Panel fanaraha-maso
Ny tontonana anoloana dia ahitana:
- Fampisehoana nomerika: Shows operational parameters such as frequency (Hz), forward/reverse status (FWD/REV), and revolutions per minute (r/min).
- famantarana: Power, Hz, FWD, REV, r/min.
- bokotra:
DISP: Display mode selection.PROG: Program mode entry/exit.FUNC/DATA: Function/Data entry.FWD/REV: Forward/Reverse direction control.▲(Up Arrow): Increase value or navigate menus.▼(Down Arrow): Decrease value or navigate menus.RUN: Start motor operation.STOP/RESET: Stop motor operation or reset errors.
- Rotary Knob: For fine adjustment of frequency or parameter values.
3.2 Terminals
The VFD is equipped with clearly labeled terminals for power input and motor output.

4. Famaritana
| endri-javatra | famaritana |
|---|---|
| MODELY | AT1-4000X |
| Naoty Voltage (fampidirana) | AC 220V (Single Phase) |
| Suitable Motor Power | 4kW |
| Fomba fanaraha-maso | V/F Open Loop |
| Output Voltage Adjustable Method | Fanaraha-maso PWM |
| Naoty Output amin'izao fotoana izao | 20A |
| Maximum Output Frequency Range | 0 - 400Hz |
| Type | Inverter Motor Drive |
| LASA | Shina Tanibe |
| Ny haben'ny fonosana (L x W x H) | 23 sm x 23 sm x 16 sm |
| Lanja fonosana | 1.498 kg |
5. Fametrahana
Before proceeding with installation and wiring, ensure all safety precautions are understood and followed. Installation should be performed by qualified personnel.
5.1 Fametrahana tontolo iainana
- Install the VFD in a clean, dry, and well-ventilated area.
- Avoid direct sunlight, high temperatures, excessive humidity, and dusty environments.
- Ensure there is sufficient space around the unit for proper heat dissipation.
- Aza apetraka eo akaikin'ny fitaovana mora mirehitra na mipoaka.
5.2 Torolàlana tariby
The VFD is designed for simple wiring. Always ensure the power supply is OFF before connecting any wires. Connect wires after removing the terminal screws.

| Terminus | asa | Description |
|---|---|---|
| L, N | AC 220V Input | Connect to single-phase AC 220V power supply. |
| U, V, W | 3-Phase AC Motor Output | Connect to the three-phase AC motor terminals. |
| GND | tany | Connect to a reliable earth ground. |
6. Torolàlana miasa
Once the VFD is correctly installed and wired, you can begin operation. Familiarize yourself with the control panel functions.
6.1 Fampandehanana fototra
- Herim-batana: Ensure all connections are secure, then apply single-phase 220V AC power to the L and N terminals. The VFD display should illuminate.
- Start Motor: Tsindrio ny
RUNbutton to start the motor. The FWD or REV indicator will light up depending on the current direction setting. - Adjust Frequency/Speed: Use the rotary knob to adjust the output frequency, which in turn controls the motor speed. The display will show the current frequency (Hz) or RPM (r/min).
- Hanova lalana: Tsindrio ny
FWD/REVbutton to toggle the motor's rotation direction. - Atsaharo ny maotera: Tsindrio ny
STOP/RESETbokotra hampijanonana ny motera.
6.2 Fandaharana Masontsivana
ny PROG SY FUNC/DATA buttons, along with the arrow keys (▲, ▼), are used to access and modify various operating parameters. Refer to the detailed programming manual (if available) for specific parameter settings relevant to your application.
- mpanao gazety
PROGto enter or exit programming mode. - Ampiasao
▲SY▼to navigate through parameter groups or individual parameters. - mpanao gazety
FUNC/DATAto select a parameter for editing or to confirm a value. - Use the rotary knob or arrow keys to change the parameter value.
- mpanao gazety
FUNC/DATAagain to save the new value.
7. Fikojakojana
Regular maintenance helps ensure the longevity and reliable operation of your VFD.
- Fanadiovana: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- rivotra: Ensure that the cooling fans and ventilation openings are not obstructed to prevent overheating.
- Fanaraha-maso: Periodically inspect all wiring connections for tightness and signs of wear or damage.
- Serivisy matihanina: Due to high internal voltages, any internal inspection or repair should only be performed by qualified service personnel. Do not attempt to open the VFD casing ny tenanao.
8. Famahana olana
Ity fizarana ity dia manome torolàlana ankapobeny ho an'ny olana mahazatra. Raha misy olana sarotra, mifandraisa amin'ny fanohanana ara-teknika.
| OLANA | Antony mety hitranga | vahaolana |
|---|---|---|
| Tsy mandeha ny VFD | No input power; Incorrect wiring | Check power supply and input wiring (L, N). |
| Tsy mandeha ny motera | Motor wiring incorrect; VFD in STOP mode; Parameter error | Verify motor wiring (U, V, W); Press RUN; Check programmed parameters. |
| Tsy mitombina ny hafainganam-pandehan'ny maotera | Incorrect V/F settings; Motor load fluctuations | Adjust V/F curve parameters; Ensure motor is suitable for load. |
| Hadisoana be loatra | Motor overloaded; Incorrect overload protection setting | Reduce motor load; Check and adjust overload protection parameters. |
If an error occurs, the VFD display may show an error code. Press the STOP/RESET button to clear the error after addressing the cause.
9. Torohevitra ho an'ny mpampiasa
- For optimal performance, ensure the VFD is matched correctly to your motor's power rating (e.g., 4kW motor for this 4kW VFD).
- When adjusting frequency, make gradual changes to avoid sudden motor stress.
- Always ensure proper grounding to prevent electrical hazards and ensure stable operation.
- Keep the VFD's ventilation clear to prevent overheating, especially during continuous operation.
10. Warranty sy fanohanana