1. Fampidirana
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Deye SUN-6K-SG04LP1-EU-SM2 series single-phase hybrid inverters. These inverters are designed for solar energy systems, offering versatile power management for both grid-tied and off-grid applications. Please read this manual thoroughly before installation and operation.

Sary 1: Eo anoloana view of the Deye Hybrid Inverter.
2. Information momba ny fiarovana
FAMPITANDREMANA: LOZA TAMIN'NY ELECTRIC. Installation and maintenance must be performed by qualified personnel only. Failure to follow these instructions may result in serious injury or death.
- Always disconnect all power sources (PV array, battery, and AC grid) before performing any service or maintenance.
- Hamarino tsara ny fanorenan'ny inverter.
- Aza miasa ny inverter raha simba na toa tsy miasa.
- Keep children and unauthorized personnel away from the inverter.
- Observe all local electrical codes and standards during installation.

Figure 2: Inverter front panel showing the 'Warning electric shock' label.
3. Ny votoatin'ny fonosana
Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your supplier.
- Hybrid Inverter x1
- Fametrahana rindrina x1
- Stainless steel anti-collision bolt M6*60 x4
- Stainless steel mounting screws M4*12 x4
- Cable fifandraisana parallèle x1
- Datalogger (tsy voatery) x1
- Batterie maripana sensor x1
- Sensor Clamp x1
- Torolàlana ho an'ny mpampiasa x1
- Magnetic ring for battery x1
- Magnetic ring for BMS and Meter communication cable x2
- Magnetic ring for AC wires x2
- DC+/DC- Plug connectors including metal terminal xN
- Solar Photovoltaic Connector Special Spanner x1

Figure 3: Visual representation of included accessories and components.
4. Famaritana
The following tables detail the technical specifications for the Deye SUN-6K-SG04LP1-EU-SM2 series hybrid inverters.
4.1. Battery Input Data & PV String Input Data

Figure 4: Detailed specifications for battery and PV input.
4.2. AC Input/Output Data, Efficiency, Protection & General Data

Figure 5: Detailed specifications for AC input/output, efficiency, protection, and general data.
5. Refy ara-batana
Refer to the diagram below for the physical dimensions of the inverter, including connectors and brackets.

Figure 6: Inverter dimensions and mounting points.
6. Fametrahana sy fametrahana
The Deye Hybrid Inverter must be installed by a certified electrician or qualified solar professional. Improper installation can lead to equipment damage, personal injury, or void the warranty.
6.1. Toerana fametrahana
- Choose a cool, dry, and well-ventilated area, away from direct sunlight and flammable materials.
- Ensure the mounting surface can support the inverter's weight (approx. 17.6-19 kg).
- Maintain adequate clearance around the inverter for proper airflow and heat dissipation.
- Mount the inverter vertically using the provided wall mounting bracket and screws.
6.2. Fifandraisana elektrika
- Fifandraisana PV: Connect the solar PV strings to the designated DC+ and DC- terminals. Observe correct polarity and voltage fetra.
- Fifandraisana bateria: Connect the battery bank to the battery terminals, ensuring correct polarity. The inverter supports Lead-acid or Lithium-ion batteries.
- Fifandraisana AC Grid: Connect the AC output to the main electrical panel or grid connection point.
- Load Connection: Connect critical loads to the inverter's load output terminals.
- Fifandraisana: Connect the parallel communication cable, datalogger (if applicable), battery temperature sensor, and sensor clamp as per the system design. The inverter supports RS485/RS232/CAN communication interfaces.
Refer to the detailed wiring diagrams in the full product manual for specific connection instructions.
7. Torolàlana miasa
Once installed and all connections are verified, the inverter can be powered on.
7.1. Startup voalohany
- Ensure all external DC and AC breakers are in the OFF position.
- Alefaso ny mpanapaka bateria.
- Turn on the PV array DC switch.
- Turn on the AC grid breaker.
- Observe the inverter's display for status indicators.

Figure 7: Inverter display and control buttons.
7.2. Fanaraha-maso
The inverter features a built-in display for real-time monitoring of system performance, including PV input, battery status, AC output, and fault codes. Optional dataloggers and monitoring modes (GPRS/WiFi/Bluetooth/4G/LAN) allow for remote monitoring and data logging.
8. Fikojakojana
Ny fikojakojana tsy tapaka dia miantoka ny fahombiazana tsara indrindra sy ny faharetan'ny inverter anao.
- Fanadiovana: Periodically clean the inverter's exterior and ventilation openings to prevent dust accumulation, which can hinder natural cooling. Use a soft, dry cloth.
- Fanaraha-maso: Annually inspect all electrical connections for tightness and signs of corrosion. Check cables for damage.
- Tontolo iainana: Ataovy azo antoka fa mijanona ao anatin'ny mari-pana sy hamandoana voafaritra ny tontolon'ny fametrahana.
Tapaho foana ny herinaratra alohan'ny hanaovana fikojakojana.
9. Famahana olana
Ity fizarana ity dia manome torolàlana ankapobeny ho an'ny olana mahazatra. Raha misy olana sarotra, mifandraisa amin'ny fanohanana ara-teknika.
9.1. Tsy misy herinaratra mivoaka
- Check if all DC and AC breakers are in the ON position.
- Hamarino ny fampidirana PV voltage sy ur.
- Jereo ny bateria voltage sy fifandraisana.
- Inspect for any fault codes displayed on the inverter screen.
9.2. Inverter Not Charging Battery
- Ensure PV input is sufficient and within operating range.
- Check battery temperature sensor connection and reading.
- Verify battery type settings in the inverter configuration.
9.3. Inverter Display Not Working
- Check the main power supply to the inverter.
- If the inverter has power but the display is blank, contact support.
10. Torohevitra ho an'ny mpampiasa
- For optimal performance, ensure your PV array is clean and free from shading.
- Regularly monitor your system's performance through the display or optional monitoring platforms to identify any anomalies early.
- Keep the inverter's ventilation clear to prevent overheating, especially in warmer climates.
11. Warranty sy fanohanana
The Deye Hybrid Inverter comes with a warranty period of 5 to 10 years. The exact warranty duration depends on the final installation site and specific terms. Please refer to the official warranty policy document for detailed information.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your authorized Deye dealer or technical support provider.